EUVIMEDEUVIMED entdecken
VergleichsstudieStudienprotokollOpen Access · CC BY 4.0

Performance of an ultra-fast deep-learning accelerated MRI screening protocol for prostate cancer compared to a standard multiparametric protocol

B Oerther, H Engel, A Nedelcu, R Strecker, T Benkert, D Nickel, E Weiland, T Mayrhofer, F Bamberg, M Benndorf, J Weiß, C Wilpert

European Radiology · 2024

DOI: 10.1007/s00330-024-10776-7 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift European Radiology, 2024. Verfasst von B Oerther und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg im Breisgau, Germany. benedic…. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Deep Learning, Multiparametric Magnetic Resonance Imaging, Sensitivity and Specificity. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To establish and evaluate an ultra-fast MRI screening protocol for prostate cancer (PCa) in comparison to the standard multiparametric (mp) protocol, reducing scan time and maintaining adequate diagnostic performance. Materials and methods This prospective single-center study included consecutive biopsy-naïve patients with suspected PCa between December 2022 and March 2023. A PI-RADSv2.1 conform mpMRI protocol was acquired in a 3 T scanner (scan time: 25 min 45 sec). In addition, two deep-learning (DL) accelerated sequences (T2- and diffusion-weighted) were acquired, serving as a screening protocol (scan time: 3 min 28 sec). Two readers evaluated image quality and the probability of PCa regarding PI-RADSv2.1 scores in two sessions. The diagnostic performance of the screening protocol with mpMRI serving as the reference standard was derived. Inter- and intra-reader agreements were evaluated using weighted kappa statistics.

Results

We included 77 patients with 97 lesions (mean age: 66 years; SD: 7.7). Diagnostic performance of the screening protocol was excellent with a sensitivity and specificity of 100%/100% and 89%/98% (cut-off ≥ PI-RADS 4) for reader 1 (R1) and reader 2 (R2), respectively. Mean image quality was 3.96 (R1) and 4.35 (R2) for the standard protocol vs. 4.74 and 4.57 for the screening protocol ( p < 0.05). Inter-reader agreement was moderate ( κ : 0.55) for the screening protocol and substantial ( κ : 0.61) for the multiparametric protocol.

Conclusion

The ultra-fast screening protocol showed similar diagnostic performance and better imaging quality compared to the mpMRI in under 15% of scan time, improving efficacy and enabling the implementation of screening protocols in clinical routine. Clinical relevance statement The ultra-fast protocol enables examinations without contrast administration, drastically reducing scan time to 3.5 min with similar diagnostic performance and better imaging quality. This facilitates patient-friendly, efficient examinations and addresses the conflict of increasing demand for examinations at currently exhausted capacities. Key Points Time-consuming MRI protocols are in conflict with an expected increase in examinations required for prostate cancer screening. An ultra-fast MRI protocol shows similar performance and better image quality compared to the standard protocol. Deep-learning acceleration facilitates efficient and patient-friendly examinations, thus improving prostate cancer screening capacity. Graphical Abstract

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prostatic NeoplasmsDeep LearningMultiparametric Magnetic Resonance ImagingSensitivity and SpecificityHumansMaleAgedProspective StudiesMiddle AgedMagnetic Resonance Imaging

Stichwörter der Autor:innen

Biparametric protocolDeep learningMRI efficiencyMultiparametric MRIProstate cancer screening

Autor:innen und Institutionen

  • Department of Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg im Breisgau, Germany. benedict.oerther@uniklinik-freiburg.de.
  • Department of Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg im Breisgau, Germany.
  • MR Application Predevelopment, Siemens Healthineers GmbH, Erlangen, Germany.
  • EMEA Scientific Partnerships, Siemens Healthineers GmbH, Erlangen, Germany.
  • School of Business Studies, Stralsund University of Applied Sciences, Stralsund, Germany.
  • Cardiovascular Imaging Research Center, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA.

Zitieren

APA

Oerther, B., Engel, H., Nedelcu, A., Strecker, R., Benkert, T., Nickel, D., Weiland, E., Mayrhofer, T., Bamberg, F., Benndorf, M., Weiß, J., & Wilpert, C. (2024). Performance of an ultra-fast deep-learning accelerated MRI screening protocol for prostate cancer compared to a standard multiparametric protocol. European Radiology. https://doi.org/10.1007/s00330-024-10776-7

Vancouver

Oerther B, Engel H, Nedelcu A, Strecker R, Benkert T, Nickel D, et al. Performance of an ultra-fast deep-learning accelerated MRI screening protocol for prostate cancer compared to a standard multiparametric protocol. European Radiology. 2024. doi:10.1007/s00330-024-10776-7

BibTeX
@article{Oerther2024,
  author = {Oerther, B and Engel, H and Nedelcu, A and Strecker, R and Benkert, T and Nickel, D and Weiland, E and Mayrhofer, T and Bamberg, F and Benndorf, M and Weiß, J and Wilpert, C},
  title = {Performance of an ultra-fast deep-learning accelerated MRI screening protocol for prostate cancer compared to a standard multiparametric protocol},
  journal = {European Radiology},
  year = {2024},
  doi = {10.1007/s00330-024-10776-7}
}
Kostenlos starten →