EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Towards a unified approach for unsupervised brain MRI Motion Artefact Detection with few shot Anomaly Detection

Niamh Belton, Misgina Tsighe Hagos, Aonghus Lawlor, Kathleen M Curran

Computerized Medical Imaging and Graphics · 2024

DOI: 10.1016/j.compmedimag.2024.102391 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Computerized Medical Imaging and Graphics, 2024. Verfasst von Niamh Belton und 3 weiteren Autor:innen. Beteiligte Einrichtung: Science Foundation Ireland Centre for Research Training in Machine Learning, Ireland; School of Medicine, University College Dublin, Ireland. Electro…. Hauptthemen laut MEDLINE: Artifacts, Magnetic Resonance Imaging, Algorithms, Brain. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Automated Motion Artefact Detection (MAD) in Magnetic Resonance Imaging (MRI) is a field of study that aims to automatically flag motion artefacts in order to prevent the requirement for a repeat scan. In this paper, we identify and tackle the three current challenges in the field of automated MAD; (1) reliance on fully-supervised training, meaning they require specific examples of Motion Artefacts (MA), (2) inconsistent use of benchmark datasets across different works and use of private datasets for testing and training of newly proposed MAD techniques and (3) a lack of sufficiently large datasets for MRI MAD. To address these challenges, we demonstrate how MAs can be identified by formulating the problem as an unsupervised Anomaly Detection (AD) task. We compare the performance of three State-of-the-Art AD algorithms DeepSVDD, Interpolated Gaussian Descriptor and FewSOME on two open-source Brain MRI datasets on the task of MAD and MA severity classification, with FewSOME achieving a MAD AUC >90% on both datasets and a Spearman Rank Correlation Coefficient of 0.8 on the task of MA severity classification. These models are trained in the few shot setting, meaning large Brain MRI datasets are not required to build robust MAD algorithms. This work also sets a standard protocol for testing MAD algorithms on open-source benchmark datasets. In addition to addressing these challenges, we demonstrate how our proposed 'anomaly-aware' scoring function improves FewSOME's MAD performance in the setting where one and two shots of the anomalous class are available for training. Code available at https://github.com/niamhbelton/Unsupervised-Brain-MRI-Motion-Artefact-Detection/.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArtifactsMagnetic Resonance ImagingAlgorithmsBrainMotionHumansImage Processing, Computer-Assisted

Stichwörter der Autor:innen

Anomaly DetectionBrain MRIDeep learningFew shotMotion Artefact DetectionSmall datasetsUnsupervised

Autor:innen und Institutionen

  • Science Foundation Ireland Centre for Research Training in Machine Learning, Ireland; School of Medicine, University College Dublin, Ireland. Electronic address: niamh.belton@ucdconnect.ie.
  • Science Foundation Ireland Centre for Research Training in Machine Learning, Ireland; School of Computer Science, University College Dublin, Ireland.
  • School of Computer Science, University College Dublin, Ireland; Insight Centre for Data Analytics, University College Dublin, Dublin, Ireland.
  • Science Foundation Ireland Centre for Research Training in Machine Learning, Ireland; School of Medicine, University College Dublin, Ireland.

Zitieren

APA

Belton, N., Hagos, M. T., Lawlor, A., & Curran, K. M. (2024). Towards a unified approach for unsupervised brain MRI Motion Artefact Detection with few shot Anomaly Detection. Computerized Medical Imaging and Graphics. https://doi.org/10.1016/j.compmedimag.2024.102391

Vancouver

Belton N, Hagos MT, Lawlor A, Curran KM. Towards a unified approach for unsupervised brain MRI Motion Artefact Detection with few shot Anomaly Detection. Computerized Medical Imaging and Graphics. 2024. doi:10.1016/j.compmedimag.2024.102391

BibTeX
@article{Belton2024,
  author = {Belton, Niamh and Hagos, Misgina Tsighe and Lawlor, Aonghus and Curran, Kathleen M},
  title = {Towards a unified approach for unsupervised brain MRI Motion Artefact Detection with few shot Anomaly Detection},
  journal = {Computerized Medical Imaging and Graphics},
  year = {2024},
  doi = {10.1016/j.compmedimag.2024.102391}
}
Kostenlos starten →