EUVIMEDEUVIMED entdecken
Open Access

Spiral cardiac quantitative susceptibility mapping for differential cardiac chamber oxygenation—Initial validation in relation to invasive blood sampling

Jiahao Li iD, Pablo Villar-Calle, Caitlin Chiu, Mahniz Reza, Nupoor Narula, Chao Li iD, Jinwei Zhang iD, Thanh D Nguyen iD, Yi Wang iD, Robert S Zhang, Jiwon Kim, Jonathan W Weinsaft und 1 weitere

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30393 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Jiahao Li und 12 weiteren Autor:innen. Beteiligte Einrichtung: Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, USA. Hauptthemen laut MEDLINE: Oxygen, Heart, Magnetic Resonance Imaging. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, NHLBI NIH HHS, National Heart, Lung, and Blood Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop a breath‐hold cardiac quantitative susceptibility mapping (QSM) sequence for noninvasive measurement of differential cardiac chamber blood oxygen saturation (ΔSO 2 ).

Methods

A non‐gated three‐dimensional stack‐of‐spirals QSM sequence was implemented to continuously sample the data throughout the cardiac cycle. Measurements of ΔSO 2 between the right and left heart chamber obtained by the proposed sequence and a previously validated navigator Cartesian QSM sequence were compared in three cohorts consisting of healthy volunteers, coronavirus disease 2019 survivors, and patients with pulmonary hypertension. In the pulmonary‐hypertension cohort, Bland–Altman plots were used to assess the agreement of ΔSO 2 values obtained by QSM and those obtained by invasive right heart catheterization (RHC).

Results

Compared with navigator QSM (average acquisition time 419 ± 158 s), spiral QSM reduced the scan time on average by over 20‐fold to a 20‐s breath‐hold. In all three cohorts, spiral QSM and navigator QSM yielded similar ΔSO 2 . Among healthy volunteers and coronavirus disease 2019 survivors, ΔSO 2 was 17.41 ± 4.35% versus 17.67 ± 4.09% for spiral and navigator QSM, respectively. In pulmonary‐hypertension patients, spiral QSM showed a slightly smaller ΔSO 2 bias and narrower 95% limits of agreement than that obtained by navigator QSM (1.09% ± 6.47% vs. 2.79% ± 6.99%) when compared with right heart catheterization.

Conclusion

Breath‐hold three‐dimensional spiral cardiac QSM for measuring differential cardiac chamber blood oxygenation is feasible and provides values in good agreement with navigator cardiac QSM and with reference right heart catheterization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OxygenHeartMagnetic Resonance ImagingHumansMaleFemaleCOVID-19AdultCardiac CatheterizationMiddle AgedOxygen SaturationHypertension, PulmonarySARS-CoV-2Breath HoldingReproducibility of ResultsAgedImaging, Three-Dimensional

Stichwörter der Autor:innen

blood oxygenationcardiac magnetic resonancequantitative susceptibility mappingright heart catheterizationspiral

Substanzen

Oxygen

Autor:innen und Institutionen

  • Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, USA.
  • Department of Radiology, Weill Cornell Medicine, New York, New York, USA.
  • Department of Medicine, Weill Cornell Medicine, New York, New York, USA.
  • School of Applied and Engineering Physics, Cornell University, Ithaca, New York, USA.

ORCID-Profile: Jiahao Li, Chao Li, Jinwei Zhang, Thanh D Nguyen, Yi Wang, Pascal Spincemaille

Förderung

  • NIH HHS
  • NHLBI NIH HHS
  • National Heart, Lung, and Blood Institute
  • National Institutes of Health

Zitieren

APA

Li, J., Villar-Calle, P., Chiu, C., Reza, M., Narula, N., Li, C., Zhang, J., Nguyen, T. D., Wang, Y., Zhang, R. S., Kim, J., Weinsaft, J. W., & Spincemaille, P. (2025). Spiral cardiac quantitative susceptibility mapping for differential cardiac chamber oxygenation—Initial validation in relation to invasive blood sampling. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30393

Vancouver

Li J, Villar-Calle P, Chiu C, Reza M, Narula N, Li C, et al. Spiral cardiac quantitative susceptibility mapping for differential cardiac chamber oxygenation—Initial validation in relation to invasive blood sampling. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30393

BibTeX
@article{Li2025,
  author = {Li, Jiahao and Villar-Calle, Pablo and Chiu, Caitlin and Reza, Mahniz and Narula, Nupoor and Li, Chao and Zhang, Jinwei and Nguyen, Thanh D and Wang, Yi and Zhang, Robert S and Kim, Jiwon and Weinsaft, Jonathan W and Spincemaille, Pascal},
  title = {Spiral cardiac quantitative susceptibility mapping for differential cardiac chamber oxygenation—Initial validation in relation to invasive blood sampling},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30393}
}
Kostenlos starten →