Spiral cardiac quantitative susceptibility mapping for differential cardiac chamber oxygenation—Initial validation in relation to invasive blood sampling
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30393 ↗At a glance
Journal article in Magnetic Resonance in Medicine, 2025. Written by Jiahao Li and 12 co-authors. Institution: Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, USA. Major MEDLINE topics: Oxygen, Heart, Magnetic Resonance Imaging. 40 references. The full text is freely available in PubMed Central. Funded by: NIH HHS, NHLBI NIH HHS, National Heart, Lung, and Blood Institute.
Abstract (original language)
Purpose
To develop a breath‐hold cardiac quantitative susceptibility mapping (QSM) sequence for noninvasive measurement of differential cardiac chamber blood oxygen saturation (ΔSO 2 ).
Methods
A non‐gated three‐dimensional stack‐of‐spirals QSM sequence was implemented to continuously sample the data throughout the cardiac cycle. Measurements of ΔSO 2 between the right and left heart chamber obtained by the proposed sequence and a previously validated navigator Cartesian QSM sequence were compared in three cohorts consisting of healthy volunteers, coronavirus disease 2019 survivors, and patients with pulmonary hypertension. In the pulmonary‐hypertension cohort, Bland–Altman plots were used to assess the agreement of ΔSO 2 values obtained by QSM and those obtained by invasive right heart catheterization (RHC).
Results
Compared with navigator QSM (average acquisition time 419 ± 158 s), spiral QSM reduced the scan time on average by over 20‐fold to a 20‐s breath‐hold. In all three cohorts, spiral QSM and navigator QSM yielded similar ΔSO 2 . Among healthy volunteers and coronavirus disease 2019 survivors, ΔSO 2 was 17.41 ± 4.35% versus 17.67 ± 4.09% for spiral and navigator QSM, respectively. In pulmonary‐hypertension patients, spiral QSM showed a slightly smaller ΔSO 2 bias and narrower 95% limits of agreement than that obtained by navigator QSM (1.09% ± 6.47% vs. 2.79% ± 6.99%) when compared with right heart catheterization.
Conclusion
Breath‐hold three‐dimensional spiral cardiac QSM for measuring differential cardiac chamber blood oxygenation is feasible and provides values in good agreement with navigator cardiac QSM and with reference right heart catheterization.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, USA.
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA.
- Department of Medicine, Weill Cornell Medicine, New York, New York, USA.
- School of Applied and Engineering Physics, Cornell University, Ithaca, New York, USA.
ORCID profiles: Jiahao Li, Chao Li, Jinwei Zhang, Thanh D Nguyen, Yi Wang, Pascal Spincemaille
Funding
- NIH HHS
- NHLBI NIH HHS
- National Heart, Lung, and Blood Institute
- National Institutes of Health
Cite
APA
Li, J., Villar-Calle, P., Chiu, C., Reza, M., Narula, N., Li, C., Zhang, J., Nguyen, T. D., Wang, Y., Zhang, R. S., Kim, J., Weinsaft, J. W., & Spincemaille, P. (2025). Spiral cardiac quantitative susceptibility mapping for differential cardiac chamber oxygenation—Initial validation in relation to invasive blood sampling. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30393
Vancouver
Li J, Villar-Calle P, Chiu C, Reza M, Narula N, Li C, et al. Spiral cardiac quantitative susceptibility mapping for differential cardiac chamber oxygenation—Initial validation in relation to invasive blood sampling. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30393
BibTeX
@article{Li2025,
author = {Li, Jiahao and Villar-Calle, Pablo and Chiu, Caitlin and Reza, Mahniz and Narula, Nupoor and Li, Chao and Zhang, Jinwei and Nguyen, Thanh D and Wang, Yi and Zhang, Robert S and Kim, Jiwon and Weinsaft, Jonathan W and Spincemaille, Pascal},
title = {Spiral cardiac quantitative susceptibility mapping for differential cardiac chamber oxygenation—Initial validation in relation to invasive blood sampling},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30393}
}
EUVIMED