Accelerated cardiac cine with spatio‐coil regularized deep learning reconstruction
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30337 ↗At a glance
Journal article in Magnetic Resonance in Medicine, 2025. Written by Omer Burak Demirel and 7 co-authors. Institution: Department of Medicine, Cardiovascular Division, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA. Major MEDLINE topics: Deep Learning, Magnetic Resonance Imaging, Cine, Algorithms, Image Processing, Computer-Assisted. Cited 2 times so far (Crossref); 58 references. Funded by: NIH HHS, NHLBI NIH HHS, National Institutes of Health.
Abstract (original language)
Purpose
To develop an iterative deep learning (DL) reconstruction with spatio‐coil regularization and multichannel k‐space data consistency for accelerated cine imaging.
Methods
This study proposes a Spatio‐Coil Regularized DL (SCR‐DL) approach for iterative deep learning reconstruction incorporating multicoil information in data consistency and regularizer. SCR‐DL uses shift‐invariant convolutional kernels to interpolate missing k‐space lines and reconstruct individual coil images, followed by a regularizer that operates simultaneously across spatial and coil dimensions using learned image priors. At 8‐fold acceleration, SCR‐DL was compared with Generalized Autocalibrating Partially Parallel Acquisition (GRAPPA), sensitivity encoding (SENSE)‐based DL and spatio‐temporal regularized (STR)–DL reconstruction. In the retrospective undersampled cine, images were quantitatively evaluated using normalized mean square error (NMSE) and structural similarity index measure (SSIM). Additionally, agreement for left‐ventricular ejection fraction and left‐ventricular mass were assessed using prospectively accelerated cine images at 2‐fold and 8‐fold accelerations.
Results
The SCR‐DL algorithm successfully reconstructed highly accelerated cine images. SCR‐DL had significant improvements in NMSE (0.03 ± 0.02) and SSIM (91.4% ± 2.7%) compared with GRAPPA (NMSE: 0.09 ± 0.04, SSIM: 69.9% ± 11.1%; p < 0.001), SENSE‐DL (NMSE: 0.07 ± 0.04, SSIM: 86.9% ± 3.2%; p < 0.001), and STR‐DL (NMSE: 0.04 ± 0.03, SSIM: 90.0% ± 2.5%; p < 0.001) with retrospective undersampled cine. Despite the 3‐fold reduction in scan time, there was no difference between left‐ventricular ejection fraction (59.8 ± 4.5 vs. 60.8 ± 4.8, p = 0.46) or left‐ventricular mass (73.6 ± 19.4 g vs. 73.2 ± 19.7 g, p = 0.95) between R = 2 and R = 8 prospectively accelerated cine images.
Conclusions
SCR‐DL enabled highly accelerated cardiac cine imaging, significantly reducing breath‐hold time. Compared with GRAPPA or SENSE‐DL, images reconstructed with SCR‐DL showed superior NMSE and SSIM.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Medicine, Cardiovascular Division, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA.
ORCID profiles: Omer Burak Demirel, Manuel Antonio Morales
Funding
- NIH HHS
- NHLBI NIH HHS
- National Institutes of Health
Cite
APA
Demirel, O. B., Ghanbari, F., Morales, M. A., Pierce, P., Johnson, S., Rodriguez, J., Street, J. A., & Nezafat, R. (2025). Accelerated cardiac cine with spatio‐coil regularized deep learning reconstruction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30337
Vancouver
Demirel OB, Ghanbari F, Morales MA, Pierce P, Johnson S, Rodriguez J, et al. Accelerated cardiac cine with spatio‐coil regularized deep learning reconstruction. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30337
BibTeX
@article{Demirel2025,
author = {Demirel, Omer Burak and Ghanbari, Fahime and Morales, Manuel Antonio and Pierce, Patrick and Johnson, Scott and Rodriguez, Jennifer and Street, Jordan Amy and Nezafat, Reza},
title = {Accelerated cardiac cine with spatio‐coil regularized deep learning reconstruction},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30337}
}
EUVIMED