EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Chemical shift–encoded multishot EPI for navigator‐free prostate DWI

Yiming Dong iD, David Atkinson iD, Kirsten Koolstra iD, Matthias J P van Osch iD, Peter Börnert

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30334 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Yiming Dong und 4 weiteren Autor:innen. Beteiligte Einrichtung: C.J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Prostatic Neoplasms, Echo-Planar Imaging, Image Interpretation, Computer-Assisted. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 69 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Dutch Research Council (NWO), Nederlandse Organisatie voor Wetenschappelijk Onderzoek.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

DWI is an important contrast for prostate MRI to enable early and accurate detection of cancer. This study introduces a Dixon 3‐shot‐EPI protocol with structured low‐rank reconstruction for navigator‐free DWI. The aim is to overcome the limitations of single‐shot EPI (ssh‐EPI), such as geometric distortions and fat signal interference, while addressing the motion‐induced phase variations of multishot EPI and simultaneously allowing water/fat separation.

Methods

DWI data were acquired from 7 healthy volunteers using both Dixon 3‐shot EPI and standard fat‐suppressed ssh‐EPI with similar scan times for comparison. Two readers evaluated image quality using a 5‐point Likert scale regarding different aspects. The ADC values were quantitatively compared between protocols. To show feasibility in a clinical setting, the protocol was applied to two patients.

Results

From the reader scores, Dixon 3‐shot EPI significantly reduced geometric distortion compared with ssh‐EPI ( p < 0.01), with no significant differences in edge definition, SNR, or overall image quality. There was no significant difference in ADC values between the two protocols. However, the Dixon multishot‐EPI protocol offered advantages such as self‐referenced B 0 map–driven distortion correction, greater flexibility in imaging parameters, and superior fat suppression. In the patient data, the lesion could be clearly identified in both protocols and on the associated ADC maps.

Conclusion

The proposed Dixon 3‐shot‐EPI protocol shows promise as an alternative to ssh‐EPI for prostate DWI, providing reduced geometric distortions and improved fat suppression. It addresses common DWI issues based on EPI and enhances scanning flexibility, indicating potential for optimized imaging.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diffusion Magnetic Resonance ImagingProstatic NeoplasmsEcho-Planar ImagingImage Interpretation, Computer-AssistedHumansMaleReproducibility of ResultsProstateImage EnhancementAlgorithmsSensitivity and SpecificityAdultMiddle Aged

Stichwörter der Autor:innen

chemical shift encodingdiffusionmultishot EPIprostatestructured low rank

Autor:innen und Institutionen

  • C.J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands.
  • Center for Medical Imaging, University College London, London, UK.
  • Philips, Best, The Netherlands.
  • Philips Research Hamburg, Hamburg, Germany.

ORCID-Profile: Yiming Dong, David Atkinson, Kirsten Koolstra, Matthias J P van Osch

Förderung

  • Dutch Research Council (NWO)
  • Nederlandse Organisatie voor Wetenschappelijk Onderzoek

Zitieren

APA

Dong, Y., Atkinson, D., Koolstra, K., van Osch, M. J. P., & Börnert, P. (2025). Chemical shift–encoded multishot EPI for navigator‐free prostate DWI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30334

Vancouver

Dong Y, Atkinson D, Koolstra K, van Osch MJP, Börnert P. Chemical shift–encoded multishot EPI for navigator‐free prostate DWI. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30334

BibTeX
@article{Dong2025,
  author = {Dong, Yiming and Atkinson, David and Koolstra, Kirsten and van Osch, Matthias J P and Börnert, Peter},
  title = {Chemical shift–encoded multishot EPI for navigator‐free prostate DWI},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30334}
}
Kostenlos starten →