Fast 3D 31 P B1+ mapping with a weighted stack of spiral trajectory at 7 T
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30321 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Mark Stephan Widmaier und 8 weiteren Autor:innen. Beteiligte Einrichtung: CIBM Center for Biomedical Imaging, Lausanne, Switzerland. Hauptthemen laut MEDLINE: Phantoms, Imaging, Imaging, Three-Dimensional, Brain, Algorithms. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NCI NIH HHS, Swiss National Science Foundation, National Institutes of Health/ National Cancer Institute.
Abstract (Originalsprache)
Purpose
Phosphorus MRS ( 31 P MRS) enables noninvasive assessment of energy metabolism, yet its application is hindered by sensitivity limitations. To overcome this, often high magnetic fields are used, leading to challenges such as spatial inhomogeneity and therefore the need for accurate flip‐angle determination in accelerated acquisitions with short TRs. In response to these challenges, we propose a novel short TR and look‐up table–based double‐angle method for fast 3D 31 P mapping (fDAM).
Methods
Our method incorporates 3D weighted stack‐of‐spiral gradient‐echo acquisitions and a frequency‐selective pulse to enable efficient mapping based on the phosphocreatine signal at 7 T. Protocols were optimized using simulations and validated through phantom experiments. The method was validated in the human brain using a 31 P 1Ch‐trasmit/32Ch‐receive coil and skeletal muscle using a birdcage 1 H/ 31 P volume coil.
Results
The results of fDAM were compared with the classical DAM. A good correlation ( r = 0.95) was obtained between the two maps. A 3D 31 P mapping in the human calf muscle was achieved in about 10:50 min using a birdcage volume coil, with a 20% extended coverage (number of voxels with SNR > 3) relative to that of the classical DAM (24 min). fDAM also enabled the first full‐brain coverage 31 P 3D mapping in approximately 10:15 min using a 1Ch‐transmit/32Ch‐receive coil. Conclusion fDAM is an efficient method for 31 P 3D mapping, showing promise for future applications in rapid 31 P MRSI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- CIBM Center for Biomedical Imaging, Lausanne, Switzerland.
- Animal Imaging and Technology, Ecole Polytechnique Federale de Lausanne (EPFL), Lausanne, Switzerland.
- Laboratory of Functional and Metabolic Imaging, Ecole Polytechnique Federale de Lausanne (EPFL), Lausanne, Switzerland.
- Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA.
- Institute of Physics, Ecole Polytechnique Federale de Lausanne (EPFL), Lausanne, Switzerland.
ORCID-Profile: Mark Stephan Widmaier, Daniel Wenz, Lijing Xin
Förderung
- NCI NIH HHS
- Swiss National Science Foundation
- National Institutes of Health/ National Cancer Institute
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
- National Cancer Institute
Zitieren
APA
Widmaier, M. S., Kaiser, A., Baup, S., Wenz, D., Pierzchała, K., Xiao, Y., Huang, Z., Jiang, Y., & Xin, L. (2025). Fast 3D 31 P B1+ mapping with a weighted stack of spiral trajectory at 7 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30321
Vancouver
Widmaier MS, Kaiser A, Baup S, Wenz D, Pierzchała K, Xiao Y, et al. Fast 3D 31 P B1+ mapping with a weighted stack of spiral trajectory at 7 T. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30321
BibTeX
@article{Widmaier2025,
author = {Widmaier, Mark Stephan and Kaiser, Antonia and Baup, Salomé and Wenz, Daniel and Pierzchała, Katarzyna and Xiao, Ying and Huang, Zhiwei and Jiang, Yun and Xin, Lijing},
title = {Fast 3D 31 P B1+ mapping with a weighted stack of spiral trajectory at 7 T},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30321}
}
EUVIMED