Quantitative mapping of renal oxygen consumption using pseudo‐continuous arterial spin labeling and quantitative susceptibility mapping in humans
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30288 ↗At a glance
Journal article in Magnetic Resonance in Medicine, 2025. Written by Yujin Jung and 2 co-authors. Institution: Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea. Major MEDLINE topics: Spin Labels, Oxygen Consumption, Kidney, Caffeine. Cited 4 times so far (Crossref); 39 references. Funded by: National Research Foundation of Korea, Korea Health Industry Development Institute.
Abstract (original language)
Purpose
To propose a new method for quantitatively mapping the renal metabolic rate of oxygen (RMRO 2 ) and to evaluate the proposed method using a caffeine challenge. Theory and Methods Pseudo‐continuous arterial spin labeling (pCASL) and QSM sequences were used to obtain MR images in the kidney. Six healthy volunteers were scanned on caffeine and control days. The pCASL and QSM images were registered using DICOM information and rigid translation. The Fick principle was applied to estimate RMRO 2 . The results on caffeine and control days were compared to evaluate the capability of the proposed method to estimate renal oxygen consumption. A paired t ‐test was used to assess the statistical significance.
Results
Estimated renal blood flow (RBF), QSM, and RMRO 2 maps were consistent with those reported in the literature. RMRO 2 values were higher than the cerebral metabolic rate of oxygen (CMRO 2 ) and were significantly reduced on the caffeine days compared to the control days, consistent with findings from non‐MRI literature.
Conclusion
The feasibility of measuring renal oxygen consumption using pCASL and QSM images was demonstrated. To the best of our knowledge, this work provides quantitative maps of renal oxygen consumption in humans for the first time. The results were consistent with the literature, including the statistically significant reduction in renal oxygen consumption with caffeine challenge. These findings suggest the potential utility of our technique in measuring renal oxygen consumption noninvasively, especially for patients with complications associated with contrast agents.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea.
ORCID profiles: Yujin Jung, Hyun-Seo Ahn, Sung-Hong Park
Funding
- National Research Foundation of Korea
- Korea Health Industry Development Institute
Cite
APA
Jung, Y., Ahn, H. S., & Park, S. H. (2025). Quantitative mapping of renal oxygen consumption using pseudo‐continuous arterial spin labeling and quantitative susceptibility mapping in humans. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30288
Vancouver
Jung Y, Ahn HS, Park SH. Quantitative mapping of renal oxygen consumption using pseudo‐continuous arterial spin labeling and quantitative susceptibility mapping in humans. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30288
BibTeX
@article{Jung2025,
author = {Jung, Yujin and Ahn, Hyun-Seo and Park, Sung-Hong},
title = {Quantitative mapping of renal oxygen consumption using pseudo‐continuous arterial spin labeling and quantitative susceptibility mapping in humans},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30288}
}