Optimization of 1 H‐MRS methods for large‐volume acquisition of low‐concentration downfield resonances at 3 T and 7 T
Magnetic Resonance in Medicine · 2025-01 · 93 (1) · 18-30
DOI: 10.1002/mrm.30273 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 09.09.2024. Verfasst von Neil E Wilson und 5 weiteren Autor:innen. Beteiligte Einrichtung: Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philad…. Hauptthemen laut MEDLINE: Tryptophan, NAD, Brain. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NHLBI NIH HHS, NIA NIH HHS, NIBIB NIH HHS.
Abstract (Originalsprache)
Purpose
This goal of this study was to optimize spectrally selective 1 H‐MRS methods for large‐volume acquisition of low‐concentration metabolites with downfield resonances at 7 T and 3 T, with particular attention paid to detection of nicotinamide adenine dinucleotide (NAD + ) and tryptophan.
Methods
Spectrally selective excitation was used to avoid magnetization‐transfer effects with water, and various sinc pulses were compared with a band‐selective, uniform response, pure‐phase (E‐BURP) pulse. Localization using a single‐slice selective pulse was compared with voxel‐based localization that used three orthogonal refocusing pulses, and low bandwidth refocusing pulses were used to take advantage of the chemical shift displacement of water. A technique for water sideband removal was added, and a method of coil channel combination for large volumes was introduced.
Results
Proposed methods were compared qualitatively with previously reported techniques at 7 T. Sinc pulses resulted in reduced water signal excitation and improved spectral quality, with a symmetric, low bandwidth‐time product pulse performing best. Single‐slice localization allowed shorter TEs with large volumes, enhancing signal, whereas low‐bandwidth slice‐selective localization greatly reduced the observed water signal. Gradient cycling helped remove water sidebands, and frequency aligning and pruning individual channels narrowed spectral linewidths. High‐quality brain spectra of NAD + and tryptophan are shown in 4 subjects at 3 T.
Conclusion
Improved spectral quality with higher downfield signal, shorter TE, lower nuisance signal, reduced artifacts, and narrower peaks was realized at 7 T. These methodological improvements allowed for previously unachievable detection of NAD + and tryptophan in human brain at 3 T in under 5 min.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
- Department of Bioengineering, School of Engineering and Applied Sciences, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
ORCID-Profile: Neil E Wilson, Ravi Prakash Reddy Nanga, Sophia Swago, Walter R Witschey
Förderung
- NHLBI NIH HHS
- NIA NIH HHS
- NIBIB NIH HHS
- National Institute of Biomedical Imaging and Bioengineering
- National Heart, Lung, and Blood Institute
- National Institute on Aging
Zitieren
APA
Wilson, N. E., Elliott, M. A., Nanga, R. P. R., Swago, S., Witschey, W. R., & Reddy, R. (2025). Optimization of 1 H‐MRS methods for large‐volume acquisition of low‐concentration downfield resonances at 3 T and 7 T. Magnetic Resonance in Medicine, 93(1), 18-30. https://doi.org/10.1002/mrm.30273
Vancouver
Wilson NE, Elliott MA, Nanga RPR, Swago S, Witschey WR, Reddy R. Optimization of 1 H‐MRS methods for large‐volume acquisition of low‐concentration downfield resonances at 3 T and 7 T. Magnetic Resonance in Medicine. 2025;93(1):18-30. doi:10.1002/mrm.30273
BibTeX
@article{Wilson2025,
author = {Wilson, Neil E and Elliott, Mark A and Nanga, Ravi Prakash Reddy and Swago, Sophia and Witschey, Walter R and Reddy, Ravinder},
title = {Optimization of 1 H‐MRS methods for large‐volume acquisition of low‐concentration downfield resonances at 3 T and 7 T},
journal = {Magnetic Resonance in Medicine},
year = {2025},
volume = {93},
number = {1},
pages = {18--30},
doi = {10.1002/mrm.30273}
}
EUVIMED