Inter‐Individual Differences in T 1 , T 2 , and Proton Density Using Quantitative Synthetic Imaging for 1 H ‐ MRS Quantification
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70254 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Samantha A Leech und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Schulich School of Engineering, University of Calgary, Calgary, Alberta, Canada. Hauptthemen laut MEDLINE: Proton Magnetic Resonance Spectroscopy, Brain, Magnetic Resonance Imaging. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Canada Research Chair in Magnetic Resonance Spectroscopy in Brain Injury and Pain, Natural Sciences and Engineering Research Council of Canada, Canada Foundation for Innovation John R. Evans Leaders Fund.
Abstract (Originalsprache)
Purpose
Metabolite concentrations can be determined from proton magnetic resonance spectroscopy ( 1 H‐MRS) data using water as an internal reference. This calculation requires tissue‐specific water T 1 and T 2 relaxation constants and proton density (PD). Although literature values are commonly used, these vary with age and within clinical conditions, potentially introducing variability or masking metabolite effects. The introduction of rapid multi‐dynamic multi‐echo (MDME) imaging to generate multiparametric maps allows fast measurement of these parameters for each individual within a single acquisition.
Methods
1 H‐MRS and MDME data were collected from 26 healthy volunteers (aged 18–40 years). The agreement between metabolite concentrations derived using individually measured T 1 , T 2 and PD values and literature‐based values was assessed. A sensitivity analysis was also used to determine the impact of extended value ranges on metabolite concentrations.
Results
Using a MDME sequence to determine individually measured T 1 , T 2 , and PD values for tissue correction was successful. Strong agreement between metabolite concentrations calculated using literature and measured values was seen, although concentrations calculated using literature values tended to be slightly higher than when using measured values. The sensitivity analysis showed T 1 relaxation contributed most strongly to the calculated concentration variability.
Conclusion
This study demonstrates the feasibility of using a MDME acquisition to acquire individual‐ specific parameter values for tissue correction. This provides a fast, effective method to acquire individual relaxation parameters, which will be highly relevant for populations where these parameters will vary (such as the elderly, pediatrics or with clinical diagnoses).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Schulich School of Engineering, University of Calgary, Calgary, Alberta, Canada.
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada.
- Hotchkiss Brain Institute, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada.
- Alberta Children's Hospital Research Institute, University of Calgary, Calgary, Alberta, Canada.
- Bangor Imaging Center, School of Psychology and Sports Science, Bangor University, Bangor, Gwynedd, UK.
- School of Psychology and Clinical Language Sciences, University of Reading, Reading, UK.
ORCID-Profile: Samantha A Leech
Förderung
- Canada Research Chair in Magnetic Resonance Spectroscopy in Brain Injury and Pain
- Natural Sciences and Engineering Research Council of Canada
- Canada Foundation for Innovation John R. Evans Leaders Fund
- Hotchkiss Brain Institute
- Alberta Children's Hospital Research Institute
- Natural Sciences and Engineering Research Council of Canada (NSERC) Canada Graduate Scholarships Doctoral Program
- Canada Research Chairs
- Canada Foundation for Innovation
Zitieren
APA
Leech, S. A., Manske, S. L., Mullins, P. G., Bell, T. K., & Harris, A. D. (2026). Inter‐Individual Differences in T 1 , T 2 , and Proton Density Using Quantitative Synthetic Imaging for 1 H ‐ MRS Quantification. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70254
Vancouver
Leech SA, Manske SL, Mullins PG, Bell TK, Harris AD. Inter‐Individual Differences in T 1 , T 2 , and Proton Density Using Quantitative Synthetic Imaging for 1 H ‐ MRS Quantification. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70254
BibTeX
@article{Leech2026,
author = {Leech, Samantha A and Manske, Sarah L and Mullins, Paul G and Bell, Tiffany K and Harris, Ashley D},
title = {Inter‐Individual Differences in T 1 , T 2 , and Proton Density Using Quantitative Synthetic Imaging for 1 H ‐ MRS Quantification},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70254}
}
EUVIMED