EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Rotary excitation of non‐sinusoidal pulsed magnetic fields: Towards non‐invasive direct detection of cardiac conduction

Petra Albertova iD, Maximilian Gram iD, Martin Blaimer iD, Wolfgang Rudolf Bauer iD, Peter Michael Jakob iD, Peter Nordbeck iD

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30190 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2024. Written by Petra Albertova and 5 co-authors. Institution: Department of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany. Major MEDLINE topics: Phantoms, Imaging, Magnetic Resonance Imaging, Magnetic Fields, Heart Conduction System. Cited 6 times so far (Crossref); 50 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

There is a need for high resolution non‐invasive imaging methods of physiologic magnetic fields. The purpose of this work is to develop a MRI detection approach for non‐sinusoidal magnetic fields based on the rotary excitation (REX) mechanism which was previously successfully applied for the detection of oscillating magnetic fields in the sub‐nT range.

Methods

The new detection concept was examined by means of Bloch simulations, evaluating the interaction effect of spin‐locked magnetization and low‐frequency pulsed magnetic fields. The REX detection approach was validated under controlled conditions in phantom experiments at 3 T. Gaussian and sinc‐shaped stimuli were investigated. In addition, the detection of artificial fields resembling a cardiac QRS complex, which is the most prominent peak visible on a magnetocardiogram, was tested.

Results

Bloch simulations demonstrated that the REX method has a high sensitivity to pulsed fields in the resonance case, which is met when the spin‐lock frequency coincides with a non‐zero Fourier component of the stimulus field. In the experiments, we found that magnetic stimuli of different durations and waveforms can be distinguished by their characteristic REX response spectrum. The detected REX amplitude was proportional to the stimulus peak amplitude ( R 2 > 0.98) and the lowest field detection was 1 nT. Furthermore, the detection of QRS‐like fields with varying QRS durations yielded significant results in a phantom setup ( p < 0.001).

Conclusion

REX detection can be transferred to non‐sinusoidal pulsed magnetic fields and could provide a non‐invasive, quantitative tool for spatially resolved assessment of cardiac biomagnetism. Potential applications include the direct detection and characterization of cardiac conduction.

Subjects

MeSH terms (MEDLINE)

Phantoms, ImagingMagnetic Resonance ImagingMagnetic FieldsHeart Conduction SystemHumansAlgorithmsComputer SimulationReproducibility of ResultsMagnetocardiographySensitivity and Specificity

Author keywords

MCGREXT1ρbiomagnetismrotary excitationspin‐lock

Authors and institutions

  • Department of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany.
  • Experimental Physics 5, University of Würzburg, Würzburg, Germany.
  • Fraunhofer Institute for Integrated Circuits IIS, Würzburg, Germany.

ORCID profiles: Petra Albertova, Maximilian Gram, Martin Blaimer, Wolfgang Rudolf Bauer, Peter Michael Jakob, Peter Nordbeck

Cite

APA

Albertova, P., Gram, M., Blaimer, M., Bauer, W. R., Jakob, P. M., & Nordbeck, P. (2024). Rotary excitation of non‐sinusoidal pulsed magnetic fields: Towards non‐invasive direct detection of cardiac conduction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30190

Vancouver

Albertova P, Gram M, Blaimer M, Bauer WR, Jakob PM, Nordbeck P. Rotary excitation of non‐sinusoidal pulsed magnetic fields: Towards non‐invasive direct detection of cardiac conduction. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30190

BibTeX
@article{Albertova2024,
  author = {Albertova, Petra and Gram, Maximilian and Blaimer, Martin and Bauer, Wolfgang Rudolf and Jakob, Peter Michael and Nordbeck, Peter},
  title = {Rotary excitation of non‐sinusoidal pulsed magnetic fields: Towards non‐invasive direct detection of cardiac conduction},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30190}
}
Start for free →