Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Petra Albertova und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany. Hauptthemen laut MEDLINE: Phantoms, Imaging, Magnetic Resonance Imaging, Magnetic Fields, Heart Conduction System. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
There is a need for high resolution non‐invasive imaging methods of physiologic magnetic fields. The purpose of this work is to develop a MRI detection approach for non‐sinusoidal magnetic fields based on the rotary excitation (REX) mechanism which was previously successfully applied for the detection of oscillating magnetic fields in the sub‐nT range.
Methods
The new detection concept was examined by means of Bloch simulations, evaluating the interaction effect of spin‐locked magnetization and low‐frequency pulsed magnetic fields. The REX detection approach was validated under controlled conditions in phantom experiments at 3 T. Gaussian and sinc‐shaped stimuli were investigated. In addition, the detection of artificial fields resembling a cardiac QRS complex, which is the most prominent peak visible on a magnetocardiogram, was tested.
Results
Bloch simulations demonstrated that the REX method has a high sensitivity to pulsed fields in the resonance case, which is met when the spin‐lock frequency coincides with a non‐zero Fourier component of the stimulus field. In the experiments, we found that magnetic stimuli of different durations and waveforms can be distinguished by their characteristic REX response spectrum. The detected REX amplitude was proportional to the stimulus peak amplitude ( R 2 > 0.98) and the lowest field detection was 1 nT. Furthermore, the detection of QRS‐like fields with varying QRS durations yielded significant results in a phantom setup ( p < 0.001).
Conclusion
REX detection can be transferred to non‐sinusoidal pulsed magnetic fields and could provide a non‐invasive, quantitative tool for spatially resolved assessment of cardiac biomagnetism. Potential applications include the direct detection and characterization of cardiac conduction.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany.
- Experimental Physics 5, University of Würzburg, Würzburg, Germany.
- Fraunhofer Institute for Integrated Circuits IIS, Würzburg, Germany.
ORCID-Profile: Petra Albertova, Maximilian Gram, Martin Blaimer, Wolfgang Rudolf Bauer, Peter Michael Jakob, Peter Nordbeck
Zitieren
APA
Albertova, P., Gram, M., Blaimer, M., Bauer, W. R., Jakob, P. M., & Nordbeck, P. (2024). Rotary excitation of non‐sinusoidal pulsed magnetic fields: Towards non‐invasive direct detection of cardiac conduction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30190
Vancouver
Albertova P, Gram M, Blaimer M, Bauer WR, Jakob PM, Nordbeck P. Rotary excitation of non‐sinusoidal pulsed magnetic fields: Towards non‐invasive direct detection of cardiac conduction. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30190
BibTeX
@article{Albertova2024,
author = {Albertova, Petra and Gram, Maximilian and Blaimer, Martin and Bauer, Wolfgang Rudolf and Jakob, Peter Michael and Nordbeck, Peter},
title = {Rotary excitation of non‐sinusoidal pulsed magnetic fields: Towards non‐invasive direct detection of cardiac conduction},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.30190}
}
EUVIMED