EUVIMEDOpdag EUVIMED
Open access · CC BY-NC-ND 4.0

Free‐breathing, fat‐corrected T 1 mapping of the liver with stack‐of‐stars MRI , and joint estimation of T 1 , PDFF , R2*, and B1+

Yavuz Muslu iD, Daiki Tamada iD, Nathan T Roberts iD, Ty A Cashen iD, Sagar Mandava iD, Steven R Kecskemeti iD, Diego Hernando iD, Scott B Reeder iD

Magnetic Resonance in Medicine · 2024-11 · 92 (5) · 1913-1932

DOI: 10.1002/mrm.30182 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, published online on 2024-06-23. Written by Yavuz Muslu and 7 co-authors. Institution: Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA. Major MEDLINE topics: Liver, Magnetic Resonance Imaging, Phantoms, Imaging, Algorithms. Cited 13 times so far (Crossref); 102 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Bayer HealthCare, NIH HHS, NIDDK NIH HHS.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

Quantitative T 1 mapping has the potential to replace biopsy for noninvasive diagnosis and quantitative staging of chronic liver disease. Conventional T 1 mapping methods are confounded by fat and inhomogeneities, resulting in unreliable T 1 estimations. Furthermore, these methods trade off spatial resolution and volumetric coverage for shorter acquisitions with only a few images obtained within a breath‐hold. This work proposes a novel, volumetric (3D), free‐breathing T 1 mapping method to account for multiple confounding factors in a single acquisition. Theory and Methods Free‐breathing, confounder‐corrected T 1 mapping was achieved through the combination of non‐Cartesian imaging, magnetization preparation, chemical shift encoding, and a variable flip angle acquisition. A subspace‐constrained, locally low‐rank image reconstruction algorithm was employed for image reconstruction. The accuracy of the proposed method was evaluated through numerical simulations and phantom experiments with a T 1 /proton density fat fraction phantom at 3.0 T. Further, the feasibility of the proposed method was investigated through contrast‐enhanced imaging in healthy volunteers, also at 3.0 T.

Results

The method showed excellent agreement with reference measurements in phantoms across a wide range of T 1 values (200 to 1000 ms, slope = 0.998 (95% confidence interval (CI) [0.963 to 1.035]), intercept = 27.1 ms (95% CI [0.4 54.6]), r 2 = 0.996), and a high level of repeatability. In vivo imaging studies demonstrated moderate agreement (slope = 1.099 (95% CI [1.067 to 1.132]), intercept = −96.3 ms (95% CI [−82.1 to −110.5]), r 2 = 0.981) compared to saturation recovery‐based T 1 maps.

Conclusion

The proposed method produces whole‐liver, confounder‐corrected T 1 maps through simultaneous estimation of T 1 , proton density fat fraction, and in a single, free‐breathing acquisition and has excellent agreement with reference measurements in phantoms.

Subjects

MeSH terms (MEDLINE)

LiverMagnetic Resonance ImagingPhantoms, ImagingAlgorithmsRespirationAdipose TissueImage Processing, Computer-AssistedHumansImaging, Three-DimensionalMaleAdultFemaleComputer SimulationImage Interpretation, Computer-AssistedReproducibility of Results

Author keywords

T1 mappingcompressed‐sensingfree‐breathing imaginginversion recoverymulti‐contrastnon‐Cartesian imaging

Authors and institutions

  • Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA.
  • Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.
  • GE HealthCare, Waukesha, Wisconsin, USA.
  • Waisman Center, University of Wisconsin-Madison, Madison, Wisconsin, USA.
  • Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA.
  • Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.

ORCID profiles: Yavuz Muslu, Daiki Tamada, Nathan T Roberts, Ty A Cashen, Sagar Mandava, Steven R Kecskemeti, Diego Hernando, Scott B Reeder

Funding

  • Bayer HealthCare
  • NIH HHS
  • NIDDK NIH HHS
  • NIBIB NIH HHS
  • National Institutes of Health
  • Bayer Diabetes Care

Cite

APA

Muslu, Y., Tamada, D., Roberts, N. T., Cashen, T. A., Mandava, S., Kecskemeti, S. R., Hernando, D., & Reeder, S. B. (2024). Free‐breathing, fat‐corrected T 1 mapping of the liver with stack‐of‐stars MRI , and joint estimation of T 1 , PDFF , R2*, and B1+. Magnetic Resonance in Medicine, 92(5), 1913-1932. https://doi.org/10.1002/mrm.30182

Vancouver

Muslu Y, Tamada D, Roberts NT, Cashen TA, Mandava S, Kecskemeti SR, et al. Free‐breathing, fat‐corrected T 1 mapping of the liver with stack‐of‐stars MRI , and joint estimation of T 1 , PDFF , R2*, and B1+. Magnetic Resonance in Medicine. 2024;92(5):1913-1932. doi:10.1002/mrm.30182

BibTeX
@article{Muslu2024,
  author = {Muslu, Yavuz and Tamada, Daiki and Roberts, Nathan T and Cashen, Ty A and Mandava, Sagar and Kecskemeti, Steven R and Hernando, Diego and Reeder, Scott B},
  title = {Free‐breathing, fat‐corrected T 1 mapping of the liver with stack‐of‐stars MRI , and joint estimation of T 1 , PDFF , R2*, and B1+},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  volume = {92},
  number = {5},
  pages = {1913--1932},
  doi = {10.1002/mrm.30182}
}
Start for free →