EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Machine learning‐based estimation of respiratory fluctuations in a healthy adult population using resting state BOLD fMRI and head motion parameters

Abdoljalil Addeh, Fernando Vega, Amin Morshedi, Rebecca J Williams, G Bruce Pike, M Ethan MacDonald iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30330 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Abdoljalil Addeh und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Schulich School of Engineering, University of Calgary, Calgary, Alberta, Canada. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Machine Learning, Respiration, Brain. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Campus Alberta Innovates Chair, Natural Sciences and Engineering Research Council, CIHR.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

External physiological monitoring is the primary approach to measure and remove effects of low‐frequency respiratory variation from BOLD‐fMRI signals. However, the acquisition of clean external respiratory data during fMRI is not always possible, so recent research has proposed using machine learning to directly estimate respiratory variation (RV), potentially obviating the need for external monitoring. In this study, we propose an extended method for reconstructing RV waveforms directly from resting state BOLD‐fMRI data in healthy adult participants with the inclusion of both BOLD signals and derived head motion parameters.

Methods

In the proposed method, 1D convolutional neural networks (1D‐CNNs) used BOLD signals and head motion parameters to reconstruct the RV waveform for the whole fMRI scan time. Resting‐state fMRI data and associated respiratory records from the Human Connectome Project in Young Adults (HCP‐YA) dataset are used to train and test the proposed method.

Results

Compared to using only BOLD‐fMRI data for a CNN input, this approach yielded improvements of 14% in mean absolute error, 24% in mean square error, 14% in correlation, and 12% in dynamic time warping. When tested on independent datasets, the method demonstrated generalizability, even in data with different TRs and physiological conditions.

Conclusion

This study shows that the respiratory variations could be reconstructed from BOLD‐fMRI data in the young adult population, and its accuracy could be improved using supportive data such as head motion parameters. The method also performed well on independent datasets with different experimental conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingMachine LearningRespirationBrainConnectomeImage Processing, Computer-AssistedHealthy VolunteersHumansAdultMaleFemaleYoung AdultHeadNeural Networks, ComputerHead MovementsMotionRestAlgorithms

Stichwörter der Autor:innen

BOLD fMRIHCP‐YAconvolutional neural networkhead pseudomotionphysiological correctionrespiratory variation

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Schulich School of Engineering, University of Calgary, Calgary, Alberta, Canada.
  • Department of Electrical & Software Engineering, Schulich School of Engineering, University of Calgary, Calgary, Alberta, Canada.
  • Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada.
  • Hotchkiss Brain Institute, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada.
  • Faculty of Health, Charles Darwin University, Casuarina, Australia.
  • Department of Clinical Neurosciences, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada.

ORCID-Profile: M Ethan MacDonald

Förderung

  • Campus Alberta Innovates Chair
  • Natural Sciences and Engineering Research Council
  • CIHR
  • Natural Sciences and Engineering Research Council of Canada
  • Canadian Institutes of Health Research

Zitieren

APA

Addeh, A., Vega, F., Morshedi, A., Williams, R. J., Pike, G. B., & MacDonald, M. E. (2025). Machine learning‐based estimation of respiratory fluctuations in a healthy adult population using resting state BOLD fMRI and head motion parameters. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30330

Vancouver

Addeh A, Vega F, Morshedi A, Williams RJ, Pike GB, MacDonald ME. Machine learning‐based estimation of respiratory fluctuations in a healthy adult population using resting state BOLD fMRI and head motion parameters. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30330

BibTeX
@article{Addeh2025,
  author = {Addeh, Abdoljalil and Vega, Fernando and Morshedi, Amin and Williams, Rebecca J and Pike, G Bruce and MacDonald, M Ethan},
  title = {Machine learning‐based estimation of respiratory fluctuations in a healthy adult population using resting state BOLD fMRI and head motion parameters},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30330}
}
Kostenlos starten →