GABA‐edited MEGA‐PRESS at 3 T: Does a measured macromolecule background improve linear combination modeling?

Christopher W Davies-Jenkins iD, Helge J Zöllner iD, Dunja Simicic iD, Steve C N Hui iD, Yulu Song iD, Kathleen E Hupfeld iD, James J Prisciandaro iD, Richard A E Edden iD, Georg Oeltzschner iD

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30158 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2024. Written by Christopher W Davies-Jenkins and 8 co-authors. Institution: The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA. Major MEDLINE topics: gamma-Aminobutyric Acid, Macromolecular Substances. Cited 8 times so far (Crossref); 71 references. The full text is freely available in PubMed Central. Funded by: NIBIB NIH HHS, NIA NIH HHS, NIAAA NIH HHS.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

The J‐difference edited γ‐aminobutyric acid (GABA) signal is contaminated by other co‐edited signals—the largest of which originates from co‐edited macromolecules (MMs)—and is consequently often reported as “GABA+.” MM signals are broader and less well‐characterized than the metabolites, and are commonly approximated using a Gaussian model parameterization. Experimentally measured MM signals are a consensus‐recommended alternative to parameterized modeling; however, they are relatively under‐studied in the context of edited MRS.

Methods

To address this limitation in the literature, we have acquired GABA‐edited MEGA‐PRESS data with pre‐inversion to null metabolite signals in 13 healthy controls. An experimental MM basis function was derived from the mean across subjects. We further derived a new parameterization of the MM signals from the experimental data, using multiple Gaussians to accurately represent their observed asymmetry. The previous single‐Gaussian parameterization, mean experimental MM spectrum and new multi‐Gaussian parameterization were compared in a three‐way analysis of a public MEGA‐PRESS dataset of 61 healthy participants.

Results

Both the experimental MMs and the multi‐Gaussian parameterization exhibited reduced fit residuals compared to the single‐Gaussian approach ( p = 0.034 and p = 0.031, respectively), suggesting they better represent the underlying data than the single‐Gaussian parameterization. Furthermore, both experimentally derived models estimated larger MM fractional contribution to the GABA+ signal for the experimental MMs (58%) and multi‐Gaussian parameterization (58%), compared to the single‐Gaussian approach (50%).

Conclusions

Our results indicate that single‐Gaussian parameterization of edited MM signals is insufficient and that both experimentally derived GABA+ spectra and their parameterized replicas improve the modeling of GABA+ spectra.

Subjects

MeSH terms (MEDLINE)

gamma-Aminobutyric AcidMacromolecular SubstancesHumansFemaleAdultMaleMagnetic Resonance SpectroscopyNormal DistributionBrainLinear ModelsAlgorithmsYoung Adult

Author keywords

GABAGABA+MEGA‐PRESSmacromoleculesmetabolite‐nulled

Substances

gamma-Aminobutyric AcidMacromolecular Substances

Authors and institutions

  • The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
  • F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA.
  • Developing Brain Institute, Children's National Hospital, Washington, District of Columbia, USA.
  • Department of Radiology, The George Washington School of Medicine and Health Sciences, Washington, District of Columbia, USA.
  • Department of Pediatrics, The George Washington School of Medicine and Health Sciences, Washington, District of Columbia, USA.
  • Department of Psychiatry and Behavioral Sciences, Addiction Sciences Division, Center for Biomedical Imaging, Medical University of South Carolina, Charleston, South Carolina, USA.

ORCID profiles: Christopher W Davies-Jenkins, Helge J Zöllner, Dunja Simicic, Steve C N Hui, Yulu Song, Kathleen E Hupfeld, James J Prisciandaro, Richard A E Edden, Georg Oeltzschner

Funding

  • NIBIB NIH HHS
  • NIA NIH HHS
  • NIAAA NIH HHS
  • NIDA NIH HHS
  • NIH HHS
  • ODCDC CDC HHS

Cite

APA

Davies-Jenkins, C. W., Zöllner, H. J., Simicic, D., Hui, S. C. N., Song, Y., Hupfeld, K. E., Prisciandaro, J. J., Edden, R. A. E., & Oeltzschner, G. (2024). GABA‐edited MEGA‐PRESS at 3 T: Does a measured macromolecule background improve linear combination modeling?. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30158

Vancouver

Davies-Jenkins CW, Zöllner HJ, Simicic D, Hui SCN, Song Y, Hupfeld KE, et al. GABA‐edited MEGA‐PRESS at 3 T: Does a measured macromolecule background improve linear combination modeling?. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30158

BibTeX
@article{DaviesJenkins2024,
  author = {Davies-Jenkins, Christopher W and Zöllner, Helge J and Simicic, Dunja and Hui, Steve C N and Song, Yulu and Hupfeld, Kathleen E and Prisciandaro, James J and Edden, Richard A E and Oeltzschner, Georg},
  title = {GABA‐edited MEGA‐PRESS at 3 T: Does a measured macromolecule background improve linear combination modeling?},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30158}
}
Start for free →