Impact of acquisition and modeling parameters on the test–retest reproducibility of edited GABA+
NMR in Biomedicine · 2024
DOI: 10.1002/nbm.5076 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, 2024. Verfasst von Kathleen E Hupfeld und 8 weiteren Autor:innen. Beteiligte Einrichtung: Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: gamma-Aminobutyric Acid, Brain. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NIA NIH HHS, NIAAA NIH HHS.
Abstract (Originalsprache)
Literature values vary widely for within‐subject test–retest reproducibility of gamma‐aminobutyric acid (GABA) measured with edited magnetic resonance spectroscopy (MRS). Reasons for this variation remain unclear. Here, we tested whether three acquisition parameters—(1) sequence complexity (two‐experiment MEscher–GArwood Point RESolved Spectroscopy [MEGA‐PRESS] vs. four‐experiment Hadamard Encoding and Reconstruction of MEGA‐Edited Spectroscopy [HERMES]); (2) editing pulse duration (14 vs. 20 ms); and (3) scanner frequency drift (interleaved water referencing [IWR] turned ON vs. OFF)—and two linear combination modeling variations—(1) three different coedited macromolecule models (called “1to1GABA”, “1to1GABAsoft”, and “3to2MM” in the Osprey software package); and (2) 0.55‐ versus 0.4‐ppm spline baseline knot spacing—affected the within‐subject coefficient of variation of GABA + macromolecules (GABA+). We collected edited MRS data from the dorsal anterior cingulate cortex from 20 participants (mean age: 30.8 ± 9.5 years; 10 males). Test and retest scans were separated by removing the participant from the scanner for 5–10 min. Each acquisition consisted of two MEGA‐PRESS and two HERMES sequences with editing pulse durations of 14 and 20 ms (referred to here as MEGA‐14, MEGA‐20, HERMES‐14, and HERMES‐20; all TE = 80 ms, 224 averages). We identified the best test–retest reproducibility following postprocessing with a composite model of the 0.9‐ and 3‐ppm macromolecules (“3to2MM”); this model performed particularly well for the HERMES data. Furthermore, sparser (0.55‐ compared with 0.4‐ppm) spline baseline knot spacing yielded generally better test–retest reproducibility for GABA+. Replicating our prior results, linear combination modeling in Osprey compared with simple peak fitting in Gannet resulted in substantially better test–retest reproducibility. However, reproducibility did not consistently differ for MEGA‐PRESS compared with HERMES, for 14‐ compared with 20‐ms editing pulses, or for IWR‐ON versus IWR‐OFF. These results highlight the importance of model selection for edited MRS studies of GABA+, particularly for clinical studies that focus on individual patient differences in GABA+ or changes following an intervention.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA.
- Department of Psychiatry and Behavioral Sciences, Addiction Sciences Division, Center for Biomedical Imaging, Medical University of South Carolina, Charleston, South Carolina, USA.
ORCID-Profile: Kathleen E Hupfeld, Helge J Zöllner, Steve C N Hui, Saipavitra Murali-Manohar, Georg Oeltzschner
Förderung
- NIBIB NIH HHS
- NIA NIH HHS
- NIAAA NIH HHS
- NIDA NIH HHS
- National Institute of Biomedical Imaging and Bioengineering
- National Institute on Aging
- National Institute on Alcohol Abuse and Alcoholism
- National Institute on Drug Abuse
Zitieren
APA
Hupfeld, K. E., Zöllner, H. J., Hui, S. C. N., Song, Y., Murali-Manohar, S., Yedavalli, V., Oeltzschner, G., Prisciandaro, J. J., & Edden, R. A. E. (2024). Impact of acquisition and modeling parameters on the test–retest reproducibility of edited GABA+. NMR in Biomedicine. https://doi.org/10.1002/nbm.5076
Vancouver
Hupfeld KE, Zöllner HJ, Hui SCN, Song Y, Murali-Manohar S, Yedavalli V, et al. Impact of acquisition and modeling parameters on the test–retest reproducibility of edited GABA+. NMR in Biomedicine. 2024. doi:10.1002/nbm.5076
BibTeX
@article{Hupfeld2024,
author = {Hupfeld, Kathleen E and Zöllner, Helge J and Hui, Steve C N and Song, Yulu and Murali-Manohar, Saipavitra and Yedavalli, Vivek and Oeltzschner, Georg and Prisciandaro, James J and Edden, Richard A E},
title = {Impact of acquisition and modeling parameters on the test–retest reproducibility of edited GABA+},
journal = {NMR in Biomedicine},
year = {2024},
doi = {10.1002/nbm.5076}
}
EUVIMED