EUVIMEDOpdag EUVIMED
Crossref

Accelerated 3D multi‐echo spin‐echo sequence with a subspace constrained reconstruction for whole mouse brain T2 mapping

Aurélien J Trotier iD, Nadège Corbin iD, Sylvain Miraux iD, Emeline J Ribot iD

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30146 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2024. Written by Aurélien J Trotier and 3 co-authors. Institution: Centre de Résonance Magnétique des Systèmes Biologiques, UMR5536, CNRS, University Bordeaux, Bordeaux, France. Major MEDLINE topics: Brain, Imaging, Three-Dimensional, Phantoms, Imaging, Algorithms. Cited 1 times so far (Crossref); 38 references. Funded by: Ligue Contre le Cancer, French Government in the framework of the University of Bordeaux's France 2030 program/RRI "IMPACT".

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To accelerate whole‐brain quantitative mapping in preclinical imaging setting.

Methods

A three‐dimensional (3D) multi‐echo spin echo sequence was highly undersampled with a variable density Poisson distribution to reduce the acquisition time. Advanced iterative reconstruction based on linear subspace constraints was employed to recover high‐quality raw images. Different subspaces, generated using exponential or extended‐phase graph (EPG) simulations or from low‐resolution calibration images, were compared. The subspace dimension was investigated in terms of precision. The method was validated on a phantom containing a wide range of and was then applied to monitor metastasis growth in the mouse brain at 4.7T. Image quality and estimation were assessed for 3 acceleration factors (6/8/10).

Results

The EPG‐based dictionary gave robust estimations of a large range of . A subspace dimension of 6 was the best compromise between precision and image quality. Combining the subspace constrained reconstruction with a highly undersampled dataset enabled the acquisition of whole‐brain maps, the detection and the monitoring of metastasis growth of less than 500 .

Conclusion

Subspace‐based reconstruction is suitable for 3D mapping. This method can be used to reach an acceleration factor up to 8, corresponding to an acquisition time of 25 min for an isotropic 3D acquisition of 156 m on the mouse brain, used here for monitoring metastases growth.

Subjects

MeSH terms (MEDLINE)

BrainImaging, Three-DimensionalPhantoms, ImagingAlgorithmsAnimalsMiceBrain NeoplasmsMagnetic Resonance ImagingReproducibility of ResultsImage Processing, Computer-Assisted

Author keywords

T 2 $$ {\mathrm{T}}_2 $$ mappingcompressed sensingmulti‐echo spin‐echosmall animalsubspace reconstruction

Authors and institutions

  • Centre de Résonance Magnétique des Systèmes Biologiques, UMR5536, CNRS, University Bordeaux, Bordeaux, France.

ORCID profiles: Aurélien J Trotier, Nadège Corbin, Sylvain Miraux, Emeline J Ribot

Funding

  • Ligue Contre le Cancer
  • French Government in the framework of the University of Bordeaux's France 2030 program/RRI "IMPACT"

Cite

APA

Trotier, A. J., Corbin, N., Miraux, S., & Ribot, E. J. (2024). Accelerated 3D multi‐echo spin‐echo sequence with a subspace constrained reconstruction for whole mouse brain T2 mapping. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30146

Vancouver

Trotier AJ, Corbin N, Miraux S, Ribot EJ. Accelerated 3D multi‐echo spin‐echo sequence with a subspace constrained reconstruction for whole mouse brain T2 mapping. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30146

BibTeX
@article{Trotier2024,
  author = {Trotier, Aurélien J and Corbin, Nadège and Miraux, Sylvain and Ribot, Emeline J},
  title = {Accelerated 3D multi‐echo spin‐echo sequence with a subspace constrained reconstruction for whole mouse brain T2 mapping},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30146}
}
Start for free →