EUVIMEDObjevte EUVIMED
Open access · CC BY 4.0

Calibration‐free parallel transmission of the cervical, thoracic, and lumbar spinal cord at 7T

Christoph S Aigner iD, Manuel F Sánchez Alarcon, Alexandre D'Astous, Eva Alonso-Ortiz iD, Julien Cohen-Adad iD, Sebastian Schmitter iD

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30137 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2024. Written by Christoph S Aigner and 5 co-authors. Institution: Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany. Major MEDLINE topics: Magnetic Resonance Imaging, Spinal Cord. Cited 8 times so far (Crossref); 38 references. The full text is freely available (open access, CC BY 4.0). Funded by: German Research Foundation, Canada Research Chair in Quantitative Magnetic Resonance Imaging, Canadian Institute of Health Research.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Purpose

To address the limitations of spinal cord imaging at ultra‐high field (UHF) due to time‐consuming parallel transmit (pTx) adjustments. This study introduces calibration‐free offline computed universal shim modes that can be applied seamlessly for different pTx RF coils and spinal cord target regions, substantially enhancing spinal cord imaging efficiency at UHF.

Methods

A library of channel‐wise relative maps for the cervical spinal cord (six datasets) and thoracic and lumbar spinal cord (nine datasets) was constructed to optimize transmit homogeneity and efficiency for these regions. A tailored B 0 shim was optimized for the cervical spine to enhance spatial magnetic field homogeneity further. The performance of the universal shims was validated using absolute saturation based mapping and high‐resolution 2D and 3D multi‐echo gradient‐recalled echo (GRE) data to assess the image quality.

Results

The proposed universal shims demonstrated a 50% improvement in efficiency compared to the default (zero phase) shim mode. homogeneity was also improved by 20%. The optimized universal shims achieved performance comparable to subject‐specific pTx adjustments, while eliminating the need for lengthy pTx calibration times, saving about 10 min per experiment.

Conclusion

The development of universal shims represents a significant advance by eliminating time‐consuming subject‐specific pTx adjustments. This approach is expected to make UHF spinal cord imaging more accessible and user‐friendly, particularly for non‐pTx experts.

Subjects

MeSH terms (MEDLINE)

Magnetic Resonance ImagingSpinal CordHumansCalibrationLumbar VertebraeAlgorithmsImage Processing, Computer-AssistedThoracic VertebraeImaging, Three-DimensionalMalePhantoms, ImagingAdultFemaleCervical Vertebrae

Author keywords

7 Teslacalibration‐freeparallel transmissionspinal corduniversal pulse

Authors and institutions

  • Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany.
  • Working Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, A Joint Cooperation between the Charité Medical Faculty and the Max-Delbrück Center for Molecular Medicine, Berlin, Germany.
  • NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montréal, Montréal, Quebec, Canada.
  • Centre de recherche du CHU Sainte-Justine, Université de Montréal, Montréal, Quebec, Canada.
  • Functional Neuroimaging Unit, CRIUGM, Université de Montréal, Montréal, Quebec, Canada.
  • Mila-Quebec AI Institute, Montréal, Quebec, Canada.

ORCID profiles: Christoph S Aigner, Eva Alonso-Ortiz, Julien Cohen-Adad, Sebastian Schmitter

Funding

  • German Research Foundation
  • Canada Research Chair in Quantitative Magnetic Resonance Imaging
  • Canadian Institute of Health Research
  • Canada Foundation for Innovation
  • Fonds de Recherche du Québec - Santé
  • Natural Sciences and Engineering Research Council of Canada
  • Canada First Research Excellence Fund
  • Courtois NeuroMod project, the Quebec BioImaging Network

Cite

APA

Aigner, C. S., Sánchez Alarcon, M. F., D'Astous, A., Alonso-Ortiz, E., Cohen-Adad, J., & Schmitter, S. (2024). Calibration‐free parallel transmission of the cervical, thoracic, and lumbar spinal cord at 7T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30137

Vancouver

Aigner CS, Sánchez Alarcon MF, D'Astous A, Alonso-Ortiz E, Cohen-Adad J, Schmitter S. Calibration‐free parallel transmission of the cervical, thoracic, and lumbar spinal cord at 7T. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30137

BibTeX
@article{Aigner2024,
  author = {Aigner, Christoph S and Sánchez Alarcon, Manuel F and D'Astous, Alexandre and Alonso-Ortiz, Eva and Cohen-Adad, Julien and Schmitter, Sebastian},
  title = {Calibration‐free parallel transmission of the cervical, thoracic, and lumbar spinal cord at 7T},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30137}
}
Start for free →