Enhanced Transmit Efficiency of a Loop Array Combined With Out‐of‐Phase Passive Dipoles for Thoracic Spinal Cord MRI at 7T
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70517 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Hugo Amat und 10 weiteren Autor:innen. Beteiligte Einrichtung: Multiwave Technologies, Marseille, France. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Spinal Cord, Thoracic Vertebrae. Die Arbeit nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Amidex, Agence Nationale de la Recherche, CNRS Ingenierie.
Abstract (Originalsprache)
Purpose
The design of radiofrequency (RF) coils tailored for the target anatomy is necessary to overcome the transmit field homogeneity and penetration issues at Ultra‐High‐Field (UHF). For the spinal cord, the optimal design has not yet been determined. This work intends to demonstrate the added value of a pair of passive dipoles placed under a conventional thoracic spine 4 × 2‐loop array.
Methods
The conventional loop array produces a broad transmit field with unnecessary lateral spread. To address this, two passive dipoles were incorporated and tuned out‐of‐phase to actively suppress these lateral side‐lobes and increase field penetration the spinal cord region. The design was numerically optimised using a homogeneous phantom, followed by human voxel model simulations to evaluate performance and specific absorption rate (SAR). Finally, a prototype was tested in a 7T scanner using a homogeneous phantom to acquire experimental maps.
Results
Human voxel model simulations demonstrated that the passive dipoles improve the transmit field distribution and predicted a 35% gain in SAR efficiency in the spinal cord region. Correspondingly, phantom experiments showed a 25% gain in transmit efficiency and 15% gain in homogeneity in a selected region of interest compared to the loop‐array‐only reference.
Conclusion
Incorporating passive dipoles effectively suppresses unwanted lateral field spread, increasing penetration depth and efficiency in the thoracic spinal cord region. While homogeneous phantom results offer proof of concept, numerical simulations suggest reliable performance in realistic spine anatomy as well as substantial SAR reduction.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Multiwave Technologies, Marseille, France.
- Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, Marseille, France.
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.
- AP-HM, Hôpital de la Timone, CEMEREM, Marseille, France.
ORCID-Profile: Hugo Amat, Marc Dubois, Aurelien Destruel, Sajad Hosseinnezhadian, David Bendahan, Stefan Enoch, Virginie Callot
Förderung
- Amidex
- Agence Nationale de la Recherche
- CNRS Ingenierie
Zitieren
APA
Amat, H., Dubois, M., Destruel, A., Hosseinnezhadian, S., Berrahou, D., Betemps, C., Trabelsi, A., Bendahan, D., Enoch, S., Callot, V., & Abdeddaim, R. (2026). Enhanced Transmit Efficiency of a Loop Array Combined With Out‐of‐Phase Passive Dipoles for Thoracic Spinal Cord MRI at 7T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70517
Vancouver
Amat H, Dubois M, Destruel A, Hosseinnezhadian S, Berrahou D, Betemps C, et al. Enhanced Transmit Efficiency of a Loop Array Combined With Out‐of‐Phase Passive Dipoles for Thoracic Spinal Cord MRI at 7T. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70517
BibTeX
@article{Amat2026,
author = {Amat, Hugo and Dubois, Marc and Destruel, Aurelien and Hosseinnezhadian, Sajad and Berrahou, Djamel and Betemps, Charles and Trabelsi, Amira and Bendahan, David and Enoch, Stefan and Callot, Virginie and Abdeddaim, Redha},
title = {Enhanced Transmit Efficiency of a Loop Array Combined With Out‐of‐Phase Passive Dipoles for Thoracic Spinal Cord MRI at 7T},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70517}
}
EUVIMED