Tensor denoising of quantitative multi‐parameter mapping
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.30050 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Helge Herthum und 1 weiteren Autor:innen. Beteiligte Einrichtung: Berlin Center for Advanced Neuroimaging, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Be…. Hauptthemen laut MEDLINE: Brain, Signal-To-Noise Ratio, Algorithms, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Purpose
Quantitative multi‐parameter mapping (MPM) provides maps of physical quantities representing physiologically meaningful tissue characteristics, which allows to investigate microstructure‐function relationships reflecting normal or pathologic processes in the brain. However, the achievable spatial resolution and stability of MPM for basic research or clinical applications is severely constrained by SNR limits of the MR acquisition process, resulting in relatively long acquisition times. To increase SNR, we denoise MPM acquisitions using principal component analysis along tensors exploiting the Marchenko‐Pastur law (tMPPCA). Methods tMPPCA denoising was applied to three sets of MPM raw data before the quantification of maps of proton density, magnetization transfer saturation, R 1 , and R 2 *. The regional SNR gain for high‐resolution MPM was investigated as well as reproducibility gains for clinically optimized protocols with moderate and high acceleration factors at different image resolutions.
Results
Substantial noise reduction in raw data was achieved, resulting in reduced noise for quantitative mapping up to sixfold without introducing bias of mean values (below 1%). Scan–rescan fluctuations were reduced up to threefold. Denoising allowed to decrease the voxel volume fourfold at the same scan time or reduce the scan time twofold at same voxel volume without loss of sensitivity. Conclusions tMPPCA denoising can (a) improve of fine spatial and temporal patterns, (b) considerably reduce scan time for clinical applications, or (c) increase resolution to potentially push cutting‐edge MPM protocols from the upper to the lower limit of the mesoscopic scale.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Berlin Center for Advanced Neuroimaging, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.
- Bernstein Center for Computational Neuroscience, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.
ORCID-Profile: Helge Herthum
Zitieren
APA
Herthum, H., & Hetzer, S. (2024). Tensor denoising of quantitative multi‐parameter mapping. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30050
Vancouver
Herthum H, Hetzer S. Tensor denoising of quantitative multi‐parameter mapping. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30050
BibTeX
@article{Herthum2024,
author = {Herthum, Helge and Hetzer, Stefan},
title = {Tensor denoising of quantitative multi‐parameter mapping},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.30050}
}
EUVIMED