EUVIMEDEUVIMED entdecken
Crossref

Q‐space imaging based on Gaussian radial basis function with Laplace regularization

Yuanjun Wang iD, Yuemin Zhu iD, Lingli Luo, Jianglin He

Magnetic Resonance in Medicine · 2024-07 · 92 (1) · 128-144

DOI: 10.1002/mrm.30049 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 15.02.2024. Verfasst von Yuanjun Wang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Medical Imaging Engineering, University of Shanghai for Science and Technology, Shanghai, China. Hauptthemen laut MEDLINE: Algorithms, Axons, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Shanghai.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To introduce the diffusion signal characteristics presented by spherical harmonics (SH) basis into the q‐space imaging method based on Gaussian radial basis function (GRBF) to robustly reconstruct ensemble average diffusion propagator (EAP) in diffusion MRI (dMRI).

Methods

We introduced the Laplacian regularization of the signal into the dMRI imaging method based on GRBF, and derived the relevant indicators of microstructure imaging and the orientation distribution function (ODF) providing fiber bundle direction information based on EAP. In addition, this method is combined with a multi‐compartment model to calculate the diameter of fiber bundle axons. The evaluation of the results included qualitative comparisons and quantitative assessments of the signal fitting.

Results

The results show that the proposed method achieves the more significant accuracy improvement in reconstructing signal. Meanwhile, ODFs estimated by the proposed method show the sharper profiles and less spurious peaks, even under the sparse and noisy conditions. In the 36 sets of axon diameter estimation experiments, 34 and 30 sets of results showed that the proposed method reduced the mean and SD of axon diameter estimates, respectively. Moreover, compared with the current state‐of‐the‐art method, the mean and SD of axon diameter estimated by the proposed method are mostly lower, with 32 and 29 of 36 groups.

Conclusion

The proposed method outperforms the GRBF regarding signal fitting and the estimation of the EAP and ODF with multi‐shell sparse samples. Moreover, it shows the potential to recover important features of microstructures with less uncertainty by using proposed method together with multi‐compartment models.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsAxonsImage Processing, Computer-AssistedHumansNormal DistributionBrainDiffusion Magnetic Resonance ImagingReproducibility of ResultsPhantoms, Imaging

Stichwörter der Autor:innen

Laplacian regularizationmicrostructure recoverymulti‐shellq‐space imaging

Autor:innen und Institutionen

  • Institute of Medical Imaging Engineering, University of Shanghai for Science and Technology, Shanghai, China.

ORCID-Profile: Yuanjun Wang, Yuemin Zhu

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Shanghai

Zitieren

APA

Wang, Y., Zhu, Y., Luo, L., & He, J. (2024). Q‐space imaging based on Gaussian radial basis function with Laplace regularization. Magnetic Resonance in Medicine, 92(1), 128-144. https://doi.org/10.1002/mrm.30049

Vancouver

Wang Y, Zhu Y, Luo L, He J. Q‐space imaging based on Gaussian radial basis function with Laplace regularization. Magnetic Resonance in Medicine. 2024;92(1):128-144. doi:10.1002/mrm.30049

BibTeX
@article{Wang2024,
  author = {Wang, Yuanjun and Zhu, Yuemin and Luo, Lingli and He, Jianglin},
  title = {Q‐space imaging based on Gaussian radial basis function with Laplace regularization},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  volume = {92},
  number = {1},
  pages = {128--144},
  doi = {10.1002/mrm.30049}
}
Kostenlos starten →