Q‐space imaging based on Gaussian radial basis function with Laplace regularization
Magnetic Resonance in Medicine · 2024-07 · 92 (1) · 128-144
DOI: 10.1002/mrm.30049 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 15.02.2024. Verfasst von Yuanjun Wang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Medical Imaging Engineering, University of Shanghai for Science and Technology, Shanghai, China. Hauptthemen laut MEDLINE: Algorithms, Axons, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Shanghai.
Abstract (Originalsprache)
Purpose
To introduce the diffusion signal characteristics presented by spherical harmonics (SH) basis into the q‐space imaging method based on Gaussian radial basis function (GRBF) to robustly reconstruct ensemble average diffusion propagator (EAP) in diffusion MRI (dMRI).
Methods
We introduced the Laplacian regularization of the signal into the dMRI imaging method based on GRBF, and derived the relevant indicators of microstructure imaging and the orientation distribution function (ODF) providing fiber bundle direction information based on EAP. In addition, this method is combined with a multi‐compartment model to calculate the diameter of fiber bundle axons. The evaluation of the results included qualitative comparisons and quantitative assessments of the signal fitting.
Results
The results show that the proposed method achieves the more significant accuracy improvement in reconstructing signal. Meanwhile, ODFs estimated by the proposed method show the sharper profiles and less spurious peaks, even under the sparse and noisy conditions. In the 36 sets of axon diameter estimation experiments, 34 and 30 sets of results showed that the proposed method reduced the mean and SD of axon diameter estimates, respectively. Moreover, compared with the current state‐of‐the‐art method, the mean and SD of axon diameter estimated by the proposed method are mostly lower, with 32 and 29 of 36 groups.
Conclusion
The proposed method outperforms the GRBF regarding signal fitting and the estimation of the EAP and ODF with multi‐shell sparse samples. Moreover, it shows the potential to recover important features of microstructures with less uncertainty by using proposed method together with multi‐compartment models.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Medical Imaging Engineering, University of Shanghai for Science and Technology, Shanghai, China.
ORCID-Profile: Yuanjun Wang, Yuemin Zhu
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Shanghai
Zitieren
APA
Wang, Y., Zhu, Y., Luo, L., & He, J. (2024). Q‐space imaging based on Gaussian radial basis function with Laplace regularization. Magnetic Resonance in Medicine, 92(1), 128-144. https://doi.org/10.1002/mrm.30049
Vancouver
Wang Y, Zhu Y, Luo L, He J. Q‐space imaging based on Gaussian radial basis function with Laplace regularization. Magnetic Resonance in Medicine. 2024;92(1):128-144. doi:10.1002/mrm.30049
BibTeX
@article{Wang2024,
author = {Wang, Yuanjun and Zhu, Yuemin and Luo, Lingli and He, Jianglin},
title = {Q‐space imaging based on Gaussian radial basis function with Laplace regularization},
journal = {Magnetic Resonance in Medicine},
year = {2024},
volume = {92},
number = {1},
pages = {128--144},
doi = {10.1002/mrm.30049}
}