Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Anja Fischer und 4 weiteren Autor:innen. Beteiligte Einrichtung: Section on Experimental Radiology, University Hospital Tübingen, Tübingen, Germany. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Computer Simulation, Body Water. Die Arbeit nennt 29 Literaturangaben. Gefördert von: Federal Ministry of Education and Research (BMBF), German Federal Ministry of Education and Research (BMBF), German Center for Diabetes Research (DZD e.V.).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Free water in cortical bone is either contained in nearly cylindrical structures (mainly Haversian canals oriented parallel to the bone axis) or in more spherically shaped pores (lacunae). Those cavities have been reported to crucially influence bone quality and mechanical stability. Susceptibility differences between bone and water can lead to water frequency shifts dependent on the geometric characteristics. The purpose of this study is to calculate and measure the frequency distribution of the water signal in MRI in dependence of the microscopic bone geometry.

Methods

Finite element modeling and analytical approaches were performed to characterize the free water components of bone. The previously introduced UTE‐FID technique providing spatially resolved FID‐spectra was used to measure the frequency distribution pixel‐wise for different orientations of the bone axis.

Results

The frequency difference between free water in spherical pores and in canals parallel to B 0 amounts up to approximately 100 Hz at 3T. Simulated resonance frequencies showed good agreement with the findings in UTE‐FID spectra. The intensity ratio of the two signal components (parallel canals and spherical pores) was found to vary between periosteal and endosteal regions.

Conclusion

Spatially resolved UTE‐FID examinations allow the determination of the frequency distribution of signals from free water in cortical bone. This frequency distribution indicates the composition of the signal contributions from nearly spherical cavities and cylindrical canals which allows for further characterization of bone structure and status.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingComputer SimulationBody WaterHumansAlgorithmsReproducibility of ResultsModels, BiologicalSensitivity and SpecificityImage Interpretation, Computer-AssistedWaterBone and BonesImage EnhancementFinite Element Analysis

Stichwörter der Autor:innen

UTE imagingbound watercortical bonefree watermagnetic resonance imaging

Substanzen

Water

Autor:innen und Institutionen

  • Section on Experimental Radiology, University Hospital Tübingen, Tübingen, Germany.
  • Institute for Diabetes Research and Metabolic Diseases (IDM) of the Helmholtz, Center Munich at the University of Tübingen, Tübingen, Germany.
  • German Center for Diabetes Research (DZD), Tübingen, Germany.
  • Karlsruhe Institute of Technology, Institute of Mechanical Process Engineering and Mechanics, Karlsruhe, Germany.

ORCID-Profile: Anja Fischer, Petros Martirosian, Jürgen Machann, Bernd Fränkle, Fritz Schick

Förderung

  • Federal Ministry of Education and Research (BMBF)
  • German Federal Ministry of Education and Research (BMBF)
  • German Center for Diabetes Research (DZD e.V.)
  • Bundesministerium für Bildung und Forschung

Zitieren

APA

Fischer, A., Martirosian, P., Machann, J., Fränkle, B., & Schick, F. (2024). Frequency shifts of free water signals from compact bone: Simulations and measurements using a UTE‐FID sequence. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30027

Vancouver

Fischer A, Martirosian P, Machann J, Fränkle B, Schick F. Frequency shifts of free water signals from compact bone: Simulations and measurements using a UTE‐FID sequence. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30027

BibTeX
@article{Fischer2024,
  author = {Fischer, Anja and Martirosian, Petros and Machann, Jürgen and Fränkle, Bernd and Schick, Fritz},
  title = {Frequency shifts of free water signals from compact bone: Simulations and measurements using a UTE‐FID sequence},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30027}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche