Non‐rigid motion‐compensated 3D whole‐heart T 2 mapping in a hybrid 3T PET‐MR system
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.29973 ↗At a glance
Journal article in Magnetic Resonance in Medicine, 2024. Written by Alina Schneider and 11 co-authors. Institution: School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK. Major MEDLINE topics: Myocardium, Myocarditis. Cited 2 times so far (Crossref); 47 references. The full text is freely available (open access, CC BY 4.0). Funded by: Wellcome Trust, NHLBI NIH HHS, EPSRC.
Abstract (original language)
Purpose
Simultaneous PET‐MRI improves inflammatory cardiac disease diagnosis. However, challenges persist in respiratory motion and mis‐registration between free‐breathing 3D PET and 2D breath‐held MR images. We propose a free‐breathing non‐rigid motion‐compensated 3D T 2 ‐mapping sequence enabling whole‐heart myocardial tissue characterization in a hybrid 3T PET‐MR system and provides non‐rigid respiratory motion fields to correct also simultaneously acquired PET data.
Methods
Free‐breathing 3D whole‐heart T 2 ‐mapping was implemented on a hybrid 3T PET‐MRI system. Three datasets were acquired with different T 2 ‐preparation modules (0, 28, 55 ms) using 3‐fold undersampled variable‐density Cartesian trajectory. Respiratory motion was estimated via virtual 3D image navigators, enabling multi‐contrast non‐rigid motion‐corrected MR reconstruction. T 2 ‐maps were computed using dictionary‐matching. Approach was tested in phantom, 8 healthy subjects, 14 MR only and 2 PET‐MR patients with suspected cardiac disease and compared with spin echo reference (phantom) and clinical 2D T 2 ‐mapping (in‐vivo).
Results
Phantom results show a high correlation ( R 2 = 0.996) between proposed approach and gold standard 2D T 2 mapping. In‐vivo 3D T 2 ‐mapping average values in healthy subjects (39.0 ± 1.4 ms) and patients (healthy tissue) (39.1 ± 1.4 ms) agree with conventional 2D T 2 ‐mapping (healthy = 38.6 ± 1.2 ms, patients = 40.3 ± 1.7 ms). Bland–Altman analysis reveals bias of 1.8 ms and 95% limits of agreement (LOA) of −2.4‐6 ms for healthy subjects, and bias of 1.3 ms and 95% LOA of −1.9 to 4.6 ms for patients.
Conclusion
Validated efficient 3D whole‐heart T 2 ‐mapping at hybrid 3T PET‐MRI provides myocardial inflammation characterization and non‐rigid respiratory motion fields for simultaneous PET data correction. Comparable T 2 values were achieved with both 3D and 2D methods. Improved image quality was observed in the PET images after MR‐based motion correction.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
- PET Centre, St Thomas' Hospital, King's College London & Guys and St Thomas' NHS Foundation Trust, London, UK.
- MR Research Collaborations, Siemens Healthcare Limited, Camberley, UK.
- Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile.
- Millenium Institute for Intelligent Healthcare Engineering iHEALTH, Santiago, Chile.
ORCID profiles: Alina Schneider, Camila Munoz
Funding
- Wellcome Trust
- NHLBI NIH HHS
- EPSRC
- National Institute for Health Research (NIHR)
- Engineering and Physical Sciences Research Council
Cite
APA
Schneider, A., Munoz, C., Hua, A., Ellis, S., Jeljeli, S., Kunze, K. P., Neji, R., Reader, A. J., Reyes, E., Ismail, T. F., Botnar, R. M., & Prieto, C. (2024). Non‐rigid motion‐compensated 3D whole‐heart T 2 mapping in a hybrid 3T PET‐MR system. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29973
Vancouver
Schneider A, Munoz C, Hua A, Ellis S, Jeljeli S, Kunze KP, et al. Non‐rigid motion‐compensated 3D whole‐heart T 2 mapping in a hybrid 3T PET‐MR system. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.29973
BibTeX
@article{Schneider2024,
author = {Schneider, Alina and Munoz, Camila and Hua, Alina and Ellis, Sam and Jeljeli, Sami and Kunze, Karl P and Neji, Radhouene and Reader, Andrew J and Reyes, Eliana and Ismail, Tevfik F and Botnar, René M and Prieto, Claudia},
title = {Non‐rigid motion‐compensated 3D whole‐heart T 2 mapping in a hybrid 3T PET‐MR system},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.29973}
}
EUVIMED