On the optimization of 3D inflow‐based vascular‐space‐occupancy ( iVASO ) MRI for the quantification of arterial cerebral blood volume ( CBVa )
Magnetic Resonance in Medicine · 2024-05 · 91 (5) · 1893-1907
DOI: 10.1002/mrm.29971 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 19.12.2023. Verfasst von Chunming Gu und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: Cerebral Blood Volume, Magnetic Resonance Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 72 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, NICHD NIH HHS, NIA NIH HHS.
Abstract (Originalsprache)
Purpose
The inflow‐based vascular‐space‐occupancy (iVASO) MRI was originally developed in a single‐slice mode to measure arterial cerebral blood volume (CBVa). When vascular crushers are applied in iVASO, the signals can be sensitized predominantly to small pial arteries and arterioles. The purpose of this study is to perform a systematic optimization and evaluation of a 3D iVASO sequence on both 3 T and 7 T for the quantification of CBVa values in the human brain.
Methods
Three sets of experiments were performed in three separate cohorts. (1) 3D iVASO MRI protocols were compared to single‐slice iVASO, and the reproducibility of whole‐brain 3D iVASO MRI was evaluated. (2) The effects from different vascular crushers in iVASO were assessed. (3) 3D iVASO MRI results were evaluated in arterial and venous blood vessels identified using ultrasmall‐superparamagnetic‐iron‐oxides–enhanced MRI to validate its arterial origin.
Results
3D iVASO scans showed signal‐to‐noise ratio (SNR) and CBVa measures consistent with single‐slice iVASO with reasonable intrasubject reproducibility. Among the iVASO scans performed with different vascular crushers, the whole‐brain 3D iVASO scan with a motion‐sensitized‐driven‐equilibrium preparation with two binomial refocusing pulses and an effective TE of 50 ms showed the best suppression of macrovascular signals, with a relatively low specific absorption rate. When no vascular crusher was applied, the CBVa maps from 3D iVASO scans showed large CBVa values in arterial vessels but well‐suppressed signals in venous vessels.
Conclusion
A whole‐brain 3D iVASO MRI scan was optimized for CBVa measurement in the human brain. When only microvascular signals are desired, a motion‐sensitized‐driven‐equilibrium–based vascular crusher with binomial refocusing pulses can be applied in 3D iVASO.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland, USA.
- Neurosection, Division of MRI Research, Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA.
- Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
- Division of Neuroradiology, Mayo Clinic College of Medicine and Science, Rochester, Minnesota, USA.
- Department of Neurology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
ORCID-Profile: Chunming Gu
Förderung
- NIH HHS
- NICHD NIH HHS
- NIA NIH HHS
- NINDS NIH HHS
- NIBIB NIH HHS
- National Institute of Biomedical Imaging and Bioengineering
- National Institute of Child Health and Human Development
- National Institute of Neurological Disorders and Stroke
Zitieren
APA
Gu, C., Li, Y., Cao, D., Miao, X., Paez, A. G., Sun, Y., Cai, J., Li, W., Li, X., Pillai, J. J., Earley, C. J., van Zijl, P. C. M., & Hua, J. (2024). On the optimization of 3D inflow‐based vascular‐space‐occupancy ( iVASO ) MRI for the quantification of arterial cerebral blood volume ( CBVa ). Magnetic Resonance in Medicine, 91(5), 1893-1907. https://doi.org/10.1002/mrm.29971
Vancouver
Gu C, Li Y, Cao D, Miao X, Paez AG, Sun Y, et al. On the optimization of 3D inflow‐based vascular‐space‐occupancy ( iVASO ) MRI for the quantification of arterial cerebral blood volume ( CBVa ). Magnetic Resonance in Medicine. 2024;91(5):1893-1907. doi:10.1002/mrm.29971
BibTeX
@article{Gu2024,
author = {Gu, Chunming and Li, Yinghao and Cao, Di and Miao, Xinyuan and Paez, Adrian G and Sun, Yuanqi and Cai, Jitong and Li, Wenbo and Li, Xu and Pillai, Jay J and Earley, Christopher J and van Zijl, Peter C M and Hua, Jun},
title = {On the optimization of 3D inflow‐based vascular‐space‐occupancy ( iVASO ) MRI for the quantification of arterial cerebral blood volume ( CBVa )},
journal = {Magnetic Resonance in Medicine},
year = {2024},
volume = {91},
number = {5},
pages = {1893--1907},
doi = {10.1002/mrm.29971}
}
EUVIMED