EUVIMEDEUVIMED entdecken
Crossref

Enhancing accuracy and precision of arterial cerebral blood volume imaging in patients with moyamoya disease: Integration of long-labeled long-delay acquisition into DANTE-prepared multi-delay arterial spin labeling

Yuki Matta, Shota Ishida, Makoto Isozaki, Naoyuki Takei, Toshiki Tateishi, Hirohiko Kimura, Tetsuya Tsujikawa

Journal of Neuroscience Methods · 2027

DOI: 10.1016/j.jneumeth.2026.110916 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Neuroscience Methods, 2027. Verfasst von Yuki Matta und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Faculty of Medical Sciences, University of Fukui, 23-3 Matsuoka-Shimoaizuki, Eiheiji, Yoshida, Fukui, 910-1193, Japan; Radio…. Hauptthemen laut MEDLINE: Moyamoya Disease, Cerebral Blood Volume, Magnetic Resonance Imaging. Die Arbeit nennt 43 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Combining the delays alternating with nutation for tailored excitation (DANTE) pulse with multi-delay arterial spin labeling (MD-ASL) enables arterial cerebral blood volume (CBVa) quantification. However, CBVa estimation may be compromised in moyamoya disease (MMD) because of prolonged arterial transit time (ATT). NEW METHOD: We developed a DANTE-prepared MD-ASL protocol incorporating a long-labeled long-delay (LLLD) acquisition to improve CBVa quantification in the presence of prolonged ATT. RESULTS: Numerical simulations demonstrated that the proposed protocol had smaller negative biases and narrower limits of agreement, indicating improved estimation accuracy and precision. In healthy participants, inclusion of the LLLD acquisition improved test-retest reproducibility. In patients with MMD, the proposed protocol yielded significantly higher CBVa values than the conventional protocol in both short and long ATT regions (short, 0.932 ± 0.218 vs. 0.918 ± 0.211 mL/100 g, P < 0.001; long, 0.663 ± 0.258 vs. 0.587 ± 0.228 mL/100 g, P < 0.001). COMPARISON WITH EXISTING METHODS: Compared with the conventional DANTE-prepared MD-ASL protocol, the proposed protocol reduced CBVa underestimation and improved estimation accuracy and precision, particularly in regions with prolonged ATT. CONCLUSIONS: The LLLD acquisition mitigates CBVa underestimation associated with prolonged ATT. Integrating an LLLD acquisition into DANTE-prepared MD-ASL improves the accuracy and precision of CBVa estimation, enabling more reliable noninvasive assessment of cerebral hemodynamics in patients with MMD.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Moyamoya DiseaseCerebral Blood VolumeMagnetic Resonance ImagingHumansSpin LabelsFemaleMaleReproducibility of ResultsAdultPerfusion Magnetic Resonance ImagingYoung AdultCerebrovascular CirculationMiddle AgedBrain

Stichwörter der Autor:innen

Arterial cerebral blood volumeArterial spin labelingCerebral perfusionMoyamoya disease

Substanzen

Spin Labels

Autor:innen und Institutionen

  • Department of Radiology, Faculty of Medical Sciences, University of Fukui, 23-3 Matsuoka-Shimoaizuki, Eiheiji, Yoshida, Fukui, 910-1193, Japan; Radiological Center, University of Fukui Hospital, 23-3 Matsuoka-Shimoaizuk…
  • Department of Radiology, Faculty of Medical Sciences, University of Fukui, 23-3 Matsuoka-Shimoaizuki, Eiheiji, Yoshida, Fukui, 910-1193, Japan; Department of Radiological Technology, Faculty of medical sciences, Kyoto U…
  • Department of Neurosurgery, Division of Medicine, Faculty of Medical Sciences, University of Fukui, 23-3 Matsuoka-Shimoaizuki, Eiheiji, Yoshida, Fukui, 910-1193, Japan.
  • GE Healthcare, 4-7-127 Asahigaoka, Hino, Tokyo, 191-0065, Japan.
  • Radiological Center, University of Fukui Hospital, 23-3 Matsuoka-Shimoaizuki, Eiheiji, Yoshida, Fukui, 910-1193, Japan.
  • Faculty of Medical Sciences, University of Fukui, 23-3 Matsuoka-Shimoaizuki, Eiheiji, Yoshida, Fukui, 910-1193, Japan; Radiology Section, National Health Insurance Echizen-cho Ota Hospital, 106-44-1 Ota, Echizen, Nyu, F…

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Matta, Y., Ishida, S., Isozaki, M., Takei, N., Tateishi, T., Kimura, H., & Tsujikawa, T. (2027). Enhancing accuracy and precision of arterial cerebral blood volume imaging in patients with moyamoya disease: Integration of long-labeled long-delay acquisition into DANTE-prepared multi-delay arterial spin labeling. Journal of Neuroscience Methods. https://doi.org/10.1016/j.jneumeth.2026.110916

Vancouver

Matta Y, Ishida S, Isozaki M, Takei N, Tateishi T, Kimura H, et al. Enhancing accuracy and precision of arterial cerebral blood volume imaging in patients with moyamoya disease: Integration of long-labeled long-delay acquisition into DANTE-prepared multi-delay arterial spin labeling. Journal of Neuroscience Methods. 2027. doi:10.1016/j.jneumeth.2026.110916

BibTeX
@article{Matta2027,
  author = {Matta, Yuki and Ishida, Shota and Isozaki, Makoto and Takei, Naoyuki and Tateishi, Toshiki and Kimura, Hirohiko and Tsujikawa, Tetsuya},
  title = {Enhancing accuracy and precision of arterial cerebral blood volume imaging in patients with moyamoya disease: Integration of long-labeled long-delay acquisition into DANTE-prepared multi-delay arterial spin labeling},
  journal = {Journal of Neuroscience Methods},
  year = {2027},
  doi = {10.1016/j.jneumeth.2026.110916}
}
Kostenlos starten →