T1 mapping of myocardium in rats using self‐gated golden‐angle acquisition
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.29846 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Jiří Vitouš und 13 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Scientific Instruments, Czech Academy of Sciences, Brno, Czechia. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Myocardium. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: European Regional Development Fund, Grantová Agentura České Republiky, Lékařská fakulta, Masarykova univerzita.
Abstract (Originalsprache)
Purpose
The aim of this study is to design a method of myocardial T1 quantification in small laboratory animals and to investigate the effects of spatiotemporal regularization and the needed acquisition duration.
Methods
We propose a compressed‐sensing approach to T1 quantification based on self‐gated inversion‐recovery radial two/three‐dimensional (2D/3D) golden‐angle stack‐of‐stars acquisition with image reconstruction performed using total‐variation spatiotemporal regularization. The method was tested on a phantom and on a healthy rat, as well as on rats in a small myocardium‐remodeling study.
Results
The results showed a good match of the T1 estimates with the results obtained using the ground‐truth method on a phantom and with the literature values for rats myocardium. The proposed 2D and 3D methods showed significant differences between normal and remodeling myocardium groups for acquisition lengths down to approximately 5 and 15 min, respectively.
Conclusions
A new 2D and 3D method for quantification of myocardial T1 in rats was proposed. We have shown the capability of both techniques to distinguish between normal and remodeling myocardial tissue. We have shown the effects of image‐reconstruction regularization weights and acquisition length on the T1 estimates.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Scientific Instruments, Czech Academy of Sciences, Brno, Czechia.
- Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno, Czechia.
- Department of Physiology, Masaryk University, Faculty of Medicine, Brno, Czechia.
- First Department of Pathology, St. Anne's University Hospital and Faculty of Medicine Masaryk University, Brno, Czechia.
- Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA.
- Department of Pharmacology, Faculty of Medicine, Masaryk University, Brno, Czechia.
ORCID-Profile: Jiří Vitouš, Radovan Jiřík, Tibor Stračina, Michal Hendrych, Jaroslav Nádeníček, Ondřej Macíček, Ye Tian, Lucie Krátká, Eva Dražanová, Marie Nováková, Petr Babula, Roman Panovský, Edward DiBella, Zenon Starčuk
Förderung
- European Regional Development Fund
- Grantová Agentura České Republiky
- Lékařská fakulta, Masarykova univerzita
- Ministerstvo Školství, Mládeže a Tělovýchovy
Zitieren
APA
Vitouš, J., Jiřík, R., Stračina, T., Hendrych, M., Nádeníček, J., Macíček, O., Tian, Y., Krátká, L., Dražanová, E., Nováková, M., Babula, P., Panovský, R., DiBella, E., & Starčuk, Z. (2024). T1 mapping of myocardium in rats using self‐gated golden‐angle acquisition. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29846
Vancouver
Vitouš J, Jiřík R, Stračina T, Hendrych M, Nádeníček J, Macíček O, et al. T1 mapping of myocardium in rats using self‐gated golden‐angle acquisition. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.29846
BibTeX
@article{Vitou2024,
author = {Vitouš, Jiří and Jiřík, Radovan and Stračina, Tibor and Hendrych, Michal and Nádeníček, Jaroslav and Macíček, Ondřej and Tian, Ye and Krátká, Lucie and Dražanová, Eva and Nováková, Marie and Babula, Petr and Panovský, Roman and DiBella, Edward and Starčuk, Zenon},
title = {T1 mapping of myocardium in rats using self‐gated golden‐angle acquisition},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.29846}
}
EUVIMED