Optimizing variable flip angles in magnetization‐prepared gradient‐echo sequences for efficient 3D‐T1ρ mapping
Magnetic Resonance in Medicine · 2023
DOI: 10.1002/mrm.29740 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2023. Verfasst von Marcelo V W Zibetti und 3 weiteren Autor:innen. Beteiligte Einrichtung: Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Magnetic Resonance Imaging. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NIAMS NIH HHS, National Institute of Arthritis and Musculoskeletal and Skin Diseases.
Abstract (Originalsprache)
Purpose
To optimize the choice of the flip angles of magnetization‐prepared gradient‐echo sequences for improved accuracy, precision, and speed of 3D‐T 1 ρ mapping.
Methods
We propose a new optimization approach for finding variable flip‐angle values that improve magnetization‐prepared gradient‐echo sequences used for 3D‐T 1 ρ mapping. This new approach can improve the accuracy and SNR, while reducing filtering effects. We demonstrate the concept in the three different versions of the magnetization‐prepared gradient‐echo sequences that are typically used for 3D‐T 1 ρ mapping and evaluate their performance in model agarose phantoms ( n = 4) and healthy volunteers ( n = 5) for knee joint imaging. We also tested the optimization with sequence parameters targeting faster acquisitions.
Results
Our results show that optimized variable flip angle can improve the accuracy and the precision of the sequences, seen as a reduction of the mean of normalized absolute difference from about 5%–6% to 3%–4% in model phantoms and from 15%–16% to 11%–13% in the knee joint, and improving SNR from about 12–28 to 22–32 in agarose phantoms and about 7–14 to 13–17 in healthy volunteers. The optimization can also compensate for the loss in quality caused by making the sequence faster. This results in sequence configurations that acquire more data per unit of time with SNR and mean of normalized absolute difference measurements close to its slower versions.
Conclusion
The optimization of the variable flip angle can be used to increase accuracy and precision, and to improve the speed of the typical imaging sequences used for quantitative 3D‐T 1 ρ mapping of the knee joint.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
- Siemens Medical Solutions USA, Malvern, Pennsylvania, USA.
ORCID-Profile: Marcelo V W Zibetti, Hector L De Moura, Mahesh B Keerthivasan, Ravinder R Regatte
Förderung
- NIBIB NIH HHS
- NIAMS NIH HHS
- National Institute of Arthritis and Musculoskeletal and Skin Diseases
- National Institute of Biomedical Imaging and Bioengineering
- Center for Advanced Imaging Innovation and Research
Zitieren
APA
Zibetti, M. V. W., De Moura, H. L., Keerthivasan, M. B., & Regatte, R. R. (2023). Optimizing variable flip angles in magnetization‐prepared gradient‐echo sequences for efficient 3D‐T1ρ mapping. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29740
Vancouver
Zibetti MVW, De Moura HL, Keerthivasan MB, Regatte RR. Optimizing variable flip angles in magnetization‐prepared gradient‐echo sequences for efficient 3D‐T1ρ mapping. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29740
BibTeX
@article{Zibetti2023,
author = {Zibetti, Marcelo V W and De Moura, Hector L and Keerthivasan, Mahesh B and Regatte, Ravinder R},
title = {Optimizing variable flip angles in magnetization‐prepared gradient‐echo sequences for efficient 3D‐T1ρ mapping},
journal = {Magnetic Resonance in Medicine},
year = {2023},
doi = {10.1002/mrm.29740}
}
EUVIMED