EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

B 1 and magnetization decay correction for hyperpolarized 129 Xe lung imaging using sequential 2D spiral acquisitions

Abdullah S Bdaiwi iD, Mariah L Costa iD, Joseph W Plummer iD, Matthew M Willmering iD, Laura L Walkup iD, Zackary I Cleveland iD

Magnetic Resonance in Medicine · 2023

DOI: 10.1002/mrm.29655 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2023. Verfasst von Abdullah S Bdaiwi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Center for Pulmonary Imaging Research, Division of Pulmonary Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Lung. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NHLBI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To mitigate signal variations caused by inhomogeneous RF and magnetization decay in hyperpolarized 129 Xe ventilation images using flip‐angle maps generated from sequential 2D spiral ventilation images acquired in a breath‐hold. Images and correction maps were compared with those obtained using conventional, 2D gradient‐recalled echo. Theory and Methods Analytical expressions to predict signal intensity and uncertainty in flip‐angle measurements were derived from the Bloch equations and validated by simulations and phantom experiments. Imaging in 129 Xe phantoms and human subjects (1 healthy, 1 cystic fibrosis) was performed using 2D gradient‐recalled echo and spiral. For both sequences, consecutive images were acquired with the same slice position during a breath‐hold (Cartesian scan time = 15 s; spiral scan time = 5 s). The ratio of these images was used to calculate flip‐angle maps and correct intensity inhomogeneities in ventilation images.

Results

Mean measured flip angle showed excellent agreement with the applied flip angle in simulations ( R 2 = 0.99) for both sequences. Mean measured flip angle agreed well with the globally applied flip angle (∼15% difference) in 129 Xe phantoms and in vivo imaging using both sequences. Corrected images displayed reduced coil‐dependent signal nonuniformity relative to uncorrected images.

Conclusions

Flip‐angle maps were obtained using sequentially acquired, 2D spiral, 129 Xe ventilation images. Signal intensity variations caused by RF‐coil inhomogeneity can be corrected by acquiring sequential single‐breath ventilation images in less than 5‐s scan time. Thus, this method can be used to remove undesirable heterogeneity while preserving physiological effects on the signal distribution.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingLungHumansRespirationPhantoms, ImagingBreath HoldingXenon Isotopes

Stichwörter der Autor:innen

B1 inhomogeneitybias field correctionflip-angle mapshyperpolarized 129Xelung ventilation imagesspiral

Substanzen

Xenon Isotopes

Autor:innen und Institutionen

  • Center for Pulmonary Imaging Research, Division of Pulmonary Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA.
  • Department of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA.
  • Department of Pediatrics, University of Cincinnati, Cincinnati, Ohio, USA.
  • Imaging Research Center, Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA.

ORCID-Profile: Abdullah S Bdaiwi, Mariah L Costa, Joseph W Plummer, Matthew M Willmering, Laura L Walkup, Zackary I Cleveland

Förderung

  • NHLBI NIH HHS

Zitieren

APA

Bdaiwi, A. S., Costa, M. L., Plummer, J. W., Willmering, M. M., Walkup, L. L., & Cleveland, Z. I. (2023). B 1 and magnetization decay correction for hyperpolarized 129 Xe lung imaging using sequential 2D spiral acquisitions. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29655

Vancouver

Bdaiwi AS, Costa ML, Plummer JW, Willmering MM, Walkup LL, Cleveland ZI. B 1 and magnetization decay correction for hyperpolarized 129 Xe lung imaging using sequential 2D spiral acquisitions. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29655

BibTeX
@article{Bdaiwi2023,
  author = {Bdaiwi, Abdullah S and Costa, Mariah L and Plummer, Joseph W and Willmering, Matthew M and Walkup, Laura L and Cleveland, Zackary I},
  title = {B 1 and magnetization decay correction for hyperpolarized 129 Xe lung imaging using sequential 2D spiral acquisitions},
  journal = {Magnetic Resonance in Medicine},
  year = {2023},
  doi = {10.1002/mrm.29655}
}
Kostenlos starten →