EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Free-breathing 3D phase-resolved functional lung MRI vs breath-hold hyperpolarized 129Xe ventilation MRI in patients with chronic obstructive pulmonary disease and healthy volunteers

Filip Klimeš, Agilo Luitger Kern, Andreas Voskrebenzev, Marcel Gutberlet, Robert Grimm, Robin Aaron Müller, Lea Behrendt, Till Frederik Kaireit, Julian Glandorf, Tawfik Moher Alsady, Frank Wacker, Jens M Hohlfeld und 1 weitere

European Radiology · 2024

DOI: 10.1007/s00330-024-10893-3 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift European Radiology, 2024. Verfasst von Filip Klimeš und 12 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Hanover, Germany. Hauptthemen laut MEDLINE: Pulmonary Disease, Chronic Obstructive, Magnetic Resonance Imaging, Imaging, Three-Dimensional, Lung. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

3D phase-resolved functional lung (PREFUL) MRI offers evaluation of pulmonary ventilation without inhalation of contrast agent. This study seeks to compare ventilation maps obtained from 3D PREFUL MRI with a direct ventilation measurement derived from 129 Xe MRI in both patients with chronic obstructive pulmonary disease (COPD) and healthy volunteers.

Methods

Thirty-one patients with COPD and 12 healthy controls underwent free-breathing 3D PREFUL MRI and breath-hold 129 Xe MRI at 1.5 T. For both MRI techniques, ventilation defect (VD) maps were determined and respective ventilation defect percentage (VDP) values were computed. All parameters of both techniques were compared by Spearman correlation coefficient ( r ) and the differences between VDP values were quantified by Bland–Altman analysis and tested for significance using Wilcoxon signed-rank test. In a regional comparison of VD maps, spatial overlap and Sørensen–Dice coefficients of healthy and defect areas were computed.

Results

On a global level, all 3D PREFUL VDP values correlated significantly to VDP measure derived by 129 Xe ventilation imaging (all r > 0.65; all p < 0.0001). 129 Xe VDP was significantly greater than 3D PREFUL derived VDP RVent (mean bias = 10.5%, p < 0.001) and VDP FVL-CM (mean bias = 11.3%, p < 0.0001) but not for VDP Combined (mean bias = 1.7%, p = 0.70). The total regional agreement of 129 Xe and 3D PREFUL VD maps ranged between 60% and 63%.

Conclusions

Free-breathing 3D PREFUL MRI showed a strong correlation with breath-hold hyperpolarized 129 Xe MRI regarding the VDP values and modest differences in the detection of VDs on a regional level. Clinical relevance statement 3D PREFUL MRI correlated with 129 Xe MRI, unveiling regional differences in COPD defect identification. This proposes 3D PREFUL MRI as a ventilation mapping surrogate, eliminating the need for extra hardware or inhaled gases. Key Points Current non-invasive evaluation techniques for lung diseases have drawbacks; 129 Xe MRI is limited by cost and availability . 3D PREFUL MRI correlated with 129 Xe MRI, with regional differences in identifying COPD defects . 3D PREFUL MRI can provide ventilation mapping without the need for additional hardware or inhaled gases .

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pulmonary Disease, Chronic ObstructiveMagnetic Resonance ImagingImaging, Three-DimensionalLungHumansMaleFemaleXenon IsotopesMiddle AgedAgedBreath HoldingCase-Control StudiesPulmonary VentilationHealthy Volunteers

Stichwörter der Autor:innen

Chronic obstructive pulmonary diseaseLungMagnetic resonance imagingVentilation

Substanzen

Xenon IsotopesXenon-129

Autor:innen und Institutionen

  • Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Hanover, Germany.
  • Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), Member of the German Centre for Lung Research, Hanover, Germany.
  • MR Application Predevelopment, Siemens Healthineers AG, Erlangen, Germany.
  • Department of Clinical Airway Research, Fraunhofer Institute for Toxicology and Experimental Medicine, Hanover, Germany.
  • Department of Respiratory Medicine, Hannover Medical School, Hanover, Germany.
  • Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Hanover, Germany. vogel-claussen.jens@mh-hannover.de.

Zitieren

APA

Klimeš, F., Kern, A. L., Voskrebenzev, A., Gutberlet, M., Grimm, R., Müller, R. A., Behrendt, L., Kaireit, T. F., Glandorf, J., Alsady, T. M., Wacker, F., Hohlfeld, J. M., & Vogel-Claussen, J. (2024). Free-breathing 3D phase-resolved functional lung MRI vs breath-hold hyperpolarized 129Xe ventilation MRI in patients with chronic obstructive pulmonary disease and healthy volunteers. European Radiology. https://doi.org/10.1007/s00330-024-10893-3

Vancouver

Klimeš F, Kern AL, Voskrebenzev A, Gutberlet M, Grimm R, Müller RA, et al. Free-breathing 3D phase-resolved functional lung MRI vs breath-hold hyperpolarized 129Xe ventilation MRI in patients with chronic obstructive pulmonary disease and healthy volunteers. European Radiology. 2024. doi:10.1007/s00330-024-10893-3

BibTeX
@article{Klime2024,
  author = {Klimeš, Filip and Kern, Agilo Luitger and Voskrebenzev, Andreas and Gutberlet, Marcel and Grimm, Robert and Müller, Robin Aaron and Behrendt, Lea and Kaireit, Till Frederik and Glandorf, Julian and Alsady, Tawfik Moher and Wacker, Frank and Hohlfeld, Jens M and Vogel-Claussen, Jens},
  title = {Free-breathing 3D phase-resolved functional lung MRI vs breath-hold hyperpolarized 129Xe ventilation MRI in patients with chronic obstructive pulmonary disease and healthy volunteers},
  journal = {European Radiology},
  year = {2024},
  doi = {10.1007/s00330-024-10893-3}
}
Kostenlos starten →