Journal article in Magnetic Resonance in Medicine, published online on 2022-10-13. Written by Kevin D Harkins and 3 co-authors. Institution: Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA. Major MEDLINE topics: Water, Magnetic Resonance Imaging. Cited 9 times so far (Crossref); 35 references. The full text is freely available in PubMed Central. Funded by: NIBIB NIH HHS, NIH HHS, National Institutes of Health.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

Extend fast, two‐dimensional (2D) methods of bound and pore water mapping in bone to arbitrary slice orientation.

Methods

To correct for slice profile artifacts caused by gradient errors of half pulse 2D ultra‐short echo time (UTE), we developed a library of predistorted gradient waveforms that can be used to interpolate optimized gradient waveforms for 2D UTE slice selection. We also developed a method to estimate and correct for a bulk phase difference between the two half pulse excitations used for 2D UTE signal excitation. Bound water images were acquired in three healthy subjects with adiabatic inversion recovery prepared 2D UTE, while pore water images were acquired after short‐T2 signals were suppressed with double adiabatic inversion recovery preparation. The repeatability of bound and pore water imaging with 2D UTE was tested by repeating acquisitions after repositioning.

Results

The library‐based interpolation of optimized slice select gradient waveforms combined with the method to estimate bulk phase between two excitations provided compact slice profiles for half pulse excited 2D UTE. Quantitative bound and pore water values were highly repeatable—the pooled SD of bound water across all three subjects was 0.38 mol H/L, while pooled SD of pore water was 0.30 mol H/L.

Conclusion

Fast, quantitative, 2D UTE‐based bound and pore water images can be acquired at arbitrary oblique orientations after correcting for errors in the slice select gradient waveform and bulk phase shift between the two half acquisitions.

Subjects

MeSH terms (MEDLINE)

WaterMagnetic Resonance ImagingHumansCortical BoneBone and BonesArtifacts

Author keywords

2D UTEbound watercortical bonehalf pulsepore waterpredistortion

Substances

Water

Authors and institutions

  • Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Institute of Image Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA.
  • Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, Tennessee, USA.
  • Orthopaedic Surgery and Rehabilitation, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Center for Bone Biology, Vanderbilt University Medical Center, Nashville, Tennessee, USA.

Funding

  • NIBIB NIH HHS
  • NIH HHS
  • National Institutes of Health

Cite

APA

Harkins, K. D., Ketsiri, T., Nyman, J. S., & Does, M. D. (2023). Fast bound and pore water mapping of cortical bone with arbitrary slice oriented two‐dimensional ultra‐short echo time. Magnetic Resonance in Medicine, 89(2), 767-773. https://doi.org/10.1002/mrm.29484

Vancouver

Harkins KD, Ketsiri T, Nyman JS, Does MD. Fast bound and pore water mapping of cortical bone with arbitrary slice oriented two‐dimensional ultra‐short echo time. Magnetic Resonance in Medicine. 2023;89(2):767-773. doi:10.1002/mrm.29484

BibTeX
@article{Harkins2023,
  author = {Harkins, Kevin D and Ketsiri, Thammathida and Nyman, Jeffry S and Does, Mark D},
  title = {Fast bound and pore water mapping of cortical bone with arbitrary slice oriented two‐dimensional ultra‐short echo time},
  journal = {Magnetic Resonance in Medicine},
  year = {2023},
  volume = {89},
  number = {2},
  pages = {767--773},
  doi = {10.1002/mrm.29484}
}
Start for free →