Influence of forehead gap size on eye protection provided by lead eyewear worn over prescription glasses: A Monte Carlo study

Ryota Shindo, Masaki Fujisawa, Keisuke Yamamoto, Kodai Sagehashi, Yohei Inaba, Koichi Chida

Medical Physics · 2026

DOI: 10.1002/mp.70734 ↗

At a glance

Journal article in Medical Physics, 2026. Written by Ryota Shindo and 5 co-authors. Institution: Department of Radiological Technology, Tohoku University Graduate School of Medicine, Sendai, Japan. Major MEDLINE topics: Monte Carlo Method, Eye Protective Devices, Radiation Protection, Lead. 72 references. The full text is freely available (open access, CC BY 4.0). Funded by: JST SPRING, Grant-in-Aid for Scientific Research from the Japan Society for the Promotion of Science, Industrial Disease Clinical Research Grant.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Due to exposure to high levels of scattered ionizing radiation, interventional radiology (IR) physicians have an elevated risk of radiation‐induced eye injuries and cataracts. Previous studies have evaluated the protective effects of regular lead glasses and recommended measures to improve radiation protection for the eyes. However, the protective effects of fit‐over eyewear—lead eyewear worn over prescription glasses—have not been thoroughly examined. Importantly, a previous study noted that the space required to accommodate prescription glasses may reduce eye protection.

Purpose

Monte Carlo (MC) simulations were performed to quantify the protective effects of fit‐over eyewear and assess the relative effectiveness of adding bottom shields to conventional lead eyewear to improve eye protection.

Methods

Conventional lead glasses comprising front and side lenses and prescription glasses with plastic lenses and titanium frames were modeled. Lead glasses with bottom shields were created by bending the lower edges of the front lenses of conventional eyewear without increasing the total lens area. Three lead lens thickness values were tested: 0.07, 0.5, and 0.75 mm. Using a mesh‐type reference computational phantom representing an adult male to simulate an IR physician, MC simulations were performed with a transcatheter arterial chemoembolization setup. The Particle and Heavy Ion Transport code system was used to calculate the radiation dose deposited in each eye‐sensitive volume. The distance ( d ) between the forehead and front lead lens varied systematically. Protective effects were evaluated using the shielding rate (%) calculated as: (1‐ D pr / D 0 ) × 100, where D 0 is the radiation dose without protection and D pr is the dose with eye protection.

Results

For the eye near the X‐ray source (left eye), the conventional models showed shielding rates >50% when the lead thickness was 0.5 or 0.75 mm and d was ≤0.5 cm. The conventional 0.07‐mm lead eyewear exhibited shielding rates

Subjects

MeSH terms (MEDLINE)

Monte Carlo MethodEye Protective DevicesRadiation ProtectionLeadEyeglassesHumansPhantoms, Imaging

Author keywords

Monte Carlo simulationPb glasses (lead eyewear)interventional radiology (IR)radiation protection

Substances

Lead

Authors and institutions

  • Department of Radiological Technology, Tohoku University Graduate School of Medicine, Sendai, Japan.
  • Division of Radiological Disasters and Medical Science, Department of Disaster Medicine, International Research Institute of Disaster Science, Tohoku University, Sendai, Japan.

Funding

  • JST SPRING
  • Grant-in-Aid for Scientific Research from the Japan Society for the Promotion of Science
  • Industrial Disease Clinical Research Grant

Cite

APA

Shindo, R., Fujisawa, M., Yamamoto, K., Sagehashi, K., Inaba, Y., & Chida, K. (2026). Influence of forehead gap size on eye protection provided by lead eyewear worn over prescription glasses: A Monte Carlo study. Medical Physics. https://doi.org/10.1002/mp.70734

Vancouver

Shindo R, Fujisawa M, Yamamoto K, Sagehashi K, Inaba Y, Chida K. Influence of forehead gap size on eye protection provided by lead eyewear worn over prescription glasses: A Monte Carlo study. Medical Physics. 2026. doi:10.1002/mp.70734

BibTeX
@article{Shindo2026,
  author = {Shindo, Ryota and Fujisawa, Masaki and Yamamoto, Keisuke and Sagehashi, Kodai and Inaba, Yohei and Chida, Koichi},
  title = {Influence of forehead gap size on eye protection provided by lead eyewear worn over prescription glasses: A Monte Carlo study},
  journal = {Medical Physics},
  year = {2026},
  doi = {10.1002/mp.70734}
}
Start for free →