Influence of forehead gap size on eye protection provided by lead eyewear worn over prescription glasses: A Monte Carlo study
Medical Physics · 2026
DOI: 10.1002/mp.70734 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, 2026. Verfasst von Ryota Shindo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Technology, Tohoku University Graduate School of Medicine, Sendai, Japan. Hauptthemen laut MEDLINE: Monte Carlo Method, Eye Protective Devices, Radiation Protection, Lead. Die Arbeit nennt 72 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: JST SPRING, Grant-in-Aid for Scientific Research from the Japan Society for the Promotion of Science, Industrial Disease Clinical Research Grant.
Abstract (Originalsprache)
Background
Due to exposure to high levels of scattered ionizing radiation, interventional radiology (IR) physicians have an elevated risk of radiation‐induced eye injuries and cataracts. Previous studies have evaluated the protective effects of regular lead glasses and recommended measures to improve radiation protection for the eyes. However, the protective effects of fit‐over eyewear—lead eyewear worn over prescription glasses—have not been thoroughly examined. Importantly, a previous study noted that the space required to accommodate prescription glasses may reduce eye protection.
Purpose
Monte Carlo (MC) simulations were performed to quantify the protective effects of fit‐over eyewear and assess the relative effectiveness of adding bottom shields to conventional lead eyewear to improve eye protection.
Methods
Conventional lead glasses comprising front and side lenses and prescription glasses with plastic lenses and titanium frames were modeled. Lead glasses with bottom shields were created by bending the lower edges of the front lenses of conventional eyewear without increasing the total lens area. Three lead lens thickness values were tested: 0.07, 0.5, and 0.75 mm. Using a mesh‐type reference computational phantom representing an adult male to simulate an IR physician, MC simulations were performed with a transcatheter arterial chemoembolization setup. The Particle and Heavy Ion Transport code system was used to calculate the radiation dose deposited in each eye‐sensitive volume. The distance ( d ) between the forehead and front lead lens varied systematically. Protective effects were evaluated using the shielding rate (%) calculated as: (1‐ D pr / D 0 ) × 100, where D 0 is the radiation dose without protection and D pr is the dose with eye protection.
Results
For the eye near the X‐ray source (left eye), the conventional models showed shielding rates >50% when the lead thickness was 0.5 or 0.75 mm and d was ≤0.5 cm. The conventional 0.07‐mm lead eyewear exhibited shielding rates
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiological Technology, Tohoku University Graduate School of Medicine, Sendai, Japan.
- Division of Radiological Disasters and Medical Science, Department of Disaster Medicine, International Research Institute of Disaster Science, Tohoku University, Sendai, Japan.
Förderung
- JST SPRING
- Grant-in-Aid for Scientific Research from the Japan Society for the Promotion of Science
- Industrial Disease Clinical Research Grant
Zitieren
APA
Shindo, R., Fujisawa, M., Yamamoto, K., Sagehashi, K., Inaba, Y., & Chida, K. (2026). Influence of forehead gap size on eye protection provided by lead eyewear worn over prescription glasses: A Monte Carlo study. Medical Physics. https://doi.org/10.1002/mp.70734
Vancouver
Shindo R, Fujisawa M, Yamamoto K, Sagehashi K, Inaba Y, Chida K. Influence of forehead gap size on eye protection provided by lead eyewear worn over prescription glasses: A Monte Carlo study. Medical Physics. 2026. doi:10.1002/mp.70734
BibTeX
@article{Shindo2026,
author = {Shindo, Ryota and Fujisawa, Masaki and Yamamoto, Keisuke and Sagehashi, Kodai and Inaba, Yohei and Chida, Koichi},
title = {Influence of forehead gap size on eye protection provided by lead eyewear worn over prescription glasses: A Monte Carlo study},
journal = {Medical Physics},
year = {2026},
doi = {10.1002/mp.70734}
}
EUVIMED