EUVIMEDEUVIMED entdecken
EvaluationsstudieOpen Access

Evaluation of motion correction on myocardial [ 1 8 F]F‐AraG PET uptake using data‐driven respiratory gating

Hannah Kim, Ryan Tang, Uttam M Shrestha, Hee-Don Chae, Jelena Levi, Robert R Flavell, Youngho Seo

Medical Physics · 2026-08 · 53 (8)

DOI: 10.1002/mp.70606 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Medical Physics, online erschienen am 29.07.2026. Verfasst von Hannah Kim und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA. Hauptthemen laut MEDLINE: Positron-Emission Tomography, Heart, Myocardium, Respiratory-Gated Imaging Techniques. Die Arbeit nennt 12 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, NHLBI NIH HHS, National Cancer Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background [ 1 8 F]F‐AraG (radio‐fluorinated 9‐β‐D‐arabinofuranosylguanine) is a PET radiotracer for imaging T‐cell activation with emerging applications in myocardial imaging. Cardiac PET is particularly susceptible to respiratory motion, which degrades spatial resolution and introduces regional variability in quantitative measurements.

Purpose

To evaluate the impact of data‐driven respiratory motion correction on myocardial image quality and quantitative stability in [ 1 8 F]F‐AraG PET within a practical whole‐body imaging workflow.

Methods

Respiratory motion correction was performed using a vendor‐implemented data‐driven gating approach (OncoFreeze AI, Siemens Healthineers), which derives motion signals from PET coincidence data without external hardware and applies phase‐based binning with motion‐compensated reconstruction. [ 1 8 F]F‐AraG PET scans from 15 healthy subjects were analyzed using two myocardial segmentation strategies: a threshold‐based method and a fixed‐size VOI approach. Quantitative metrics (SUVmean, SUVmax, and volume) were assessed alongside spatial resolution using full width at half maximum (FWHM) as a surrogate of motion‐induced blurring.

Results

Motion correction reduced myocardial FWHM on average (global mean decrease ∼0.6 mm), indicating improved spatial resolution and reduced motion‐related blurring. Threshold‐based segmentation yielded variable uptake and volume estimates due to spillover and saturation effects, whereas the fixed VOI approach demonstrated preserved quantitative uptake with minimal changes in SUVmean (< 1%). Motion correction reduced apparent myocardial volume, consistent with improved myocardial boundary definition. While variability in FWHM and SUV persisted due to redistribution of counts across respiratory bins, the overall effect reflected a balance between reduced motion blur and increased statistical noise.

Conclusions

Data‐driven respiratory motion correction improves myocardial spatial resolution and reduces regional differences in motion‐related blurring in [ 1 8 F]F‐AraG PET while preserving quantitative uptake measurements. Within a standard whole‐body PET workflow without dedicated cardiac gating, this approach provides a practical strategy to enhance image fidelity, particularly for tracers with subtle myocardial uptake.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positron-Emission TomographyHeartMyocardiumRespiratory-Gated Imaging TechniquesImage Processing, Computer-AssistedHumansMovementBiological Transport

Stichwörter der Autor:innen

[18F]F‐AraGcardiac PETdata‐driven respiratory motion correction

Autor:innen und Institutionen

  • Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA.
  • CellSight Technologies, Inc., San Francisco, California, USA.
  • Department of Nuclear Engineering, University of California, Berkeley, California, USA.

Förderung

  • NCI NIH HHS
  • NHLBI NIH HHS
  • National Cancer Institute
  • National Heart, Lung, and Blood Institute

Zitieren

APA

Kim, H., Tang, R., Shrestha, U. M., Chae, H. D., Levi, J., Flavell, R. R., & Seo, Y. (2026). Evaluation of motion correction on myocardial [ 1 8 F]F‐AraG PET uptake using data‐driven respiratory gating. Medical Physics, 53(8). https://doi.org/10.1002/mp.70606

Vancouver

Kim H, Tang R, Shrestha UM, Chae HD, Levi J, Flavell RR, et al. Evaluation of motion correction on myocardial [ 1 8 F]F‐AraG PET uptake using data‐driven respiratory gating. Medical Physics. 2026;53(8). doi:10.1002/mp.70606

BibTeX
@article{Kim2026,
  author = {Kim, Hannah and Tang, Ryan and Shrestha, Uttam M and Chae, Hee-Don and Levi, Jelena and Flavell, Robert R and Seo, Youngho},
  title = {Evaluation of motion correction on myocardial [ 1 8 F]F‐AraG PET uptake using data‐driven respiratory gating},
  journal = {Medical Physics},
  year = {2026},
  volume = {53},
  number = {8},
  doi = {10.1002/mp.70606}
}
Kostenlos starten →