Time‐resolved PET imaging using a joint dynamic reconstruction and motion estimation framework (DREME‐PET)

Ruizhi Zuo, Hua-Chieh Shao, Rameshwar Prasad, Jing Wang, You Zhang

Medical Physics · 2026-08 · 53 (8)

DOI: 10.1002/mp.70593 ↗

At a glance

Journal article in Medical Physics, published online on 2026-08-04. Written by Ruizhi Zuo and 4 co-authors. Institution: The Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Cent…. Major MEDLINE topics: Positron-Emission Tomography, Image Processing, Computer-Assisted. 73 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIH HHS, NCI NIH HHS, NIBIB NIH HHS.

AbstraktSubjectsDane bibliograficzneCiteRelated studies

Abstract (original language)

Background

Positron emission tomography (PET) plays a critical role in image‐guided radiotherapy by enabling accurate tumor localization and contouring. To account for respiration‐induced anatomical motion, time‐resolved PET imaging is highly desirable, as it captures dynamic anatomical variations to facilitate both disease diagnosis and treatment. However, reconstructing time‐resolved PET images is highly challenging due to the severely limited counts available within each short temporal frame (∼0.5 s) and the intrinsic ill‐posed nature of the inverse problem.

Purpose

We proposed a time‐resolved PET imaging technique based on a dynamic reconstruction and motion estimation framework (DREME‐PET). The framework enables time‐resolved volumetric PET imaging and respiratory motion tracking directly from low‐count PET list‐mode data. Materials and methods From a conventional PET scan, DREME‐PET reconstructs time‐resolved PET images while simultaneously generating a patient‐specific, data‐driven motion model. Based on the solved image and motion model by the time‐resolved reconstruction, DREME‐PET also enables real‐time PET and motion prediction based on subsequently acquired, minimal list‐mode data. Specifically, DREME‐PET employs spatial implicit neural representation (INR) to represent a reference volumetric PET image, and a corresponding low‐rank motion model to map the reference PET image to the time‐resolved PET sequence. The motion model comprises a trainable B‐spline‐based interpolant to represent the low‐rank motion basis components (MBC) and a CNN‐based motion encoder to derive the MBC scores from time‐resolved, low‐count list‐mode data. In addition to the count and motion variations observed in the training PET scan, the CNN encoder was trained with additional count‐ and motion‐augmentation to render it generalizable to a broader range of motion amplitudes and count variations (to account for the activity decay). DREME‐PET are evaluated with an XCAT simulation study, an in‐house physical phantom measurement, and a patient study.

Results

DREME‐PET allows accurate time‐resolved PET reconstruction and motion modeling from a single PET scan, and enables real‐time image and motion predictions from subsequent list‐mode data acquisitions at a fast inference speed (28 ms per frame). For the XCAT simulation study, DREME‐PET achieves an average (±s.d.) image contrast relative error of 14.1% ± 3.0% and a tumor center‐of‐mass tracking error of 1.7 ± 0.8 mm. The physical phantom study shows an image contrast relative error of 7.4% ± 6.2% and a target center‐of‐mass tracking error of 0.5 ± 0.5 mm. The patient study shows a Pearson correlation higher than 0.91 and image contrast relative error of 3.6% ± 0.4%.

Conclusions

DREME‐PET allows accurate time‐resolved PET reconstruction and motion modeling using a conventional, pre‐treatment‐delivery PET scan. Based on the derived motion model, it also enables real‐time, intra‐delivery PET imaging and motion tracking with minimal list‐mode data to benefit applications such as PET‐guided adaptive radiotherapy.

Subjects

MeSH terms (MEDLINE)

Positron-Emission TomographyImage Processing, Computer-AssistedMovementTime FactorsHumansPhantoms, ImagingRespiration

Author keywords

image reconstructionlow‐count PETmotion modelreal‐time motion trackingtime‐resolved imaging

Authors and institutions

  • The Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.

Funding

  • NIH HHS
  • NCI NIH HHS
  • NIBIB NIH HHS
  • National Institutes of Health

Cite

APA

Zuo, R., Shao, H. C., Prasad, R., Wang, J., & Zhang, Y. (2026). Time‐resolved PET imaging using a joint dynamic reconstruction and motion estimation framework (DREME‐PET). Medical Physics, 53(8). https://doi.org/10.1002/mp.70593

Vancouver

Zuo R, Shao HC, Prasad R, Wang J, Zhang Y. Time‐resolved PET imaging using a joint dynamic reconstruction and motion estimation framework (DREME‐PET). Medical Physics. 2026;53(8). doi:10.1002/mp.70593

BibTeX
@article{Zuo2026,
  author = {Zuo, Ruizhi and Shao, Hua-Chieh and Prasad, Rameshwar and Wang, Jing and Zhang, You},
  title = {Time‐resolved PET imaging using a joint dynamic reconstruction and motion estimation framework (DREME‐PET)},
  journal = {Medical Physics},
  year = {2026},
  volume = {53},
  number = {8},
  doi = {10.1002/mp.70593}
}
Start for free →