Development and characterization of a novel, small animal external beam irradiator using a clinical high dose rate brachytherapy source
Medical Physics · 2026-07 · 53 (7)
DOI: 10.1002/mp.70540 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, online erschienen am 30.06.2026. Verfasst von Daniel Cecchi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia, Canada. Hauptthemen laut MEDLINE: Brachytherapy, Radiation Dosage. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council (NSERC) Canadian Graduates Research Scholarship, NSERC Discovery, Canadian Institutes of Health Research (CIHR).
Abstract (Originalsprache)
Background
Pre‐clinical in vivo characterization is a necessary step in the translation of novel radiotherapeutic interventions to clinical application. In vivo irradiations using a radioactive source like Ir‐192 are challenging due to steep dose gradients and absence of universally available applicators that do not require physical contact or interstitial insertion.
Purpose
To develop a novel external beam radiotherapy (EBRT) jig for accurate and reproducible radiotherapy treatments delivered using an Ir‐192 source for in vivo studies.
Methods
An irradiation jig was constructed as a flat treatment bed and upright 6 cm diameter semi‐circle with eight peripheral catheter positions encompassing the lateral side of a mouse. A CT scan was acquired of the jig along with a silicone phantom of a mouse with flank tumor. The scan was imported into Oncentra® for planning using 500 cGy prescribed to the tumor and calculated using TG43 and collapsed cone. EBT4 film and OSLD measurements verified dose distributions in the axial and coronal directions along with the entrance and exit dose to the tumor. Monte Carlo simulations using TOPAS™ were used to observe the 3D dose distribution within the tumor itself. Five female immunodeficient mice inoculated with HEC‐1A cervical cancer tumors were irradiated and monitored for 3 weeks for tumor growth, body weight, and signs of toxicity.
Results
Dosimetry measurements agreed within 2%–15% of the tumor's entrance and exit dose as reported by Oncentra® using both computational formalisms. Monte Carlo simulations confirmed a uniform dose distribution within the tumor of ± 10%. Compared to unirradiated mice, a significant reduction in tumor growth post‐irradiation was observed in all irradiated mice with no observable signs of toxicity.
Conclusion
We have successfully developed an EBRT platform for in vivo irradiations with an Ir‐192 source. The platform can be adapted for various tumor and sample sizes and other radioactive sources.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia, Canada.
- BC Cancer - Victoria, Victoria, British Columbia, Canada.
- BC Cancer - Vancouver, Vancouver, British Columbia, Canada.
- Department of Computer Science, Mathematics, Physics, and Statistics, University of British Columbia-Okanagan, Kelowna, British Columbia, Canada.
- Centre for Advanced Materials and Related Technologies (CAMTEC), University of Victoria, Victoria, British Columbia, Canada.
- Division of Radiation Oncology, University of British Columbia, Vancouver, British Columbia, Canada.
Förderung
- Natural Sciences and Engineering Research Council (NSERC) Canadian Graduates Research Scholarship
- NSERC Discovery
- Canadian Institutes of Health Research (CIHR)
Zitieren
APA
Cecchi, D., Freeman, S., Warren, G., Gill, B., Johnstone, C., Chithrani, D. B., & Lloyd, S. A. M. (2026). Development and characterization of a novel, small animal external beam irradiator using a clinical high dose rate brachytherapy source. Medical Physics, 53(7). https://doi.org/10.1002/mp.70540
Vancouver
Cecchi D, Freeman S, Warren G, Gill B, Johnstone C, Chithrani DB, et al. Development and characterization of a novel, small animal external beam irradiator using a clinical high dose rate brachytherapy source. Medical Physics. 2026;53(7). doi:10.1002/mp.70540
BibTeX
@article{Cecchi2026,
author = {Cecchi, Daniel and Freeman, Sacha and Warren, Greg and Gill, Brad and Johnstone, Chris and Chithrani, Devika B and Lloyd, Samantha A M},
title = {Development and characterization of a novel, small animal external beam irradiator using a clinical high dose rate brachytherapy source},
journal = {Medical Physics},
year = {2026},
volume = {53},
number = {7},
doi = {10.1002/mp.70540}
}
EUVIMED