Monte Carlo modeling and phantom studies show Cherenkov emission per unit dose during total skin electron therapy is a function of tissue optical properties
Medical Physics · 2026-06 · 53 (6)
DOI: 10.1002/mp.70521 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, online erschienen am 08.06.2026. Verfasst von Yifeng Zhu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA. Hauptthemen laut MEDLINE: Monte Carlo Method, Electrons, Phantoms, Imaging, Skin. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, NIBIB NIH HHS.
Abstract (Originalsprache)
Background
Cherenkov imaging provides a noninvasive approach to visualize total skin electron therapy (TSET) radiation dose deposition on patient. Accurate conversion of Cherenkov intensity to radiation dose is necessary for in vivo dosimetry to assess the spatial dose distribution in TSET. Studies have shown a linear correlation between Cherenkov intensity and absorbed dose, but the effect of tissue optical properties on the Cherenkov emission per dose is not well understood.
Purpose
This work uses Monte Carlo simulations and experiments to assess how tissue optical properties affect the Cherenkov emission per dose detected during TSET.
Methods
Monte Carlo modeling was used to simulate Cherenkov generation during total skin electron therapy and quantify the effect of tissue optical properties on the detected Cherenkov emission. The study examined a clinically relevant range of absorption coefficients (0.01–1 cm −1 ) and reduced scattering coefficients (2–40 cm −1 ) at 665 nm. The effect of tissue optical properties, depth of origin and the angular distribution of Cherenkov emission on tissue surface were systematically evaluated. The Monte Carlo results are compared to measurements for a series of solid phantoms. An analytical function is proposed to fit the optical properties dependence (µ a and µ s ’) of Cherenkov emission for tissue.
Results
Simulation results show that Cherenkov emission decreases with increasing tissue absorption and effective attenuation coefficients but increases then decreases with tissue scattering coefficients. 80% of the surface‐detected emission originated from superficial layers 0.17‐ 2.0 cm beneath the surface. Angle‐specific generation of Cherenkov radiation in tissue has not resulted in preferential exiting angle as the propagation directions of most Cherenkov photons are randomized prior to reaching the surface. Monte Carlo simulation (max dev 0.23%) agrees with experiments to within a standard (maximum) % deviation of 2.8% (7.6%).
Conclusion
Our findings indicate that tissue optical properties exert a substantial influence on the surface Cherenkov emission. The optical properties dependence of Cherenkov emission per dose can be expressed as a two‐dimensional function of µ a and µ s ’. An analytical expression is presented. Monte Carlo simulation agrees with experiments for TSE electrons used in a series of tissue simulating phantoms.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
- Department of Periodontics, School of Dental Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Förderung
- NCI NIH HHS
- NIBIB NIH HHS
Zitieren
APA
Zhu, Y., Ong, Y. H., Byrd, B. K., Alexander, D. A., Johnson, M., Sourvanos, D., & Zhu, T. C. (2026). Monte Carlo modeling and phantom studies show Cherenkov emission per unit dose during total skin electron therapy is a function of tissue optical properties. Medical Physics, 53(6). https://doi.org/10.1002/mp.70521
Vancouver
Zhu Y, Ong YH, Byrd BK, Alexander DA, Johnson M, Sourvanos D, et al. Monte Carlo modeling and phantom studies show Cherenkov emission per unit dose during total skin electron therapy is a function of tissue optical properties. Medical Physics. 2026;53(6). doi:10.1002/mp.70521
BibTeX
@article{Zhu2026,
author = {Zhu, Yifeng and Ong, Yi Hong and Byrd, Brook K and Alexander, Daniel A and Johnson, Madelyn and Sourvanos, Dennis and Zhu, Timothy C},
title = {Monte Carlo modeling and phantom studies show Cherenkov emission per unit dose during total skin electron therapy is a function of tissue optical properties},
journal = {Medical Physics},
year = {2026},
volume = {53},
number = {6},
doi = {10.1002/mp.70521}
}