EUVIMEDEUVIMED entdecken
Crossref

Simultaneous multi‐band multi‐spectral imaging using multi‐band RF excitation for accelerated metal artifact reduction in MRI‐guided interventions

Penghui Luo, Jiantai Zhou, Lin Chen, Changliang Wang, Kecheng Yuan, Xiaoyan Huang, Yufu Zhou, Xuechun Jiao, Fulang Qi, Bensheng Qiu

Medical Physics · 2026

DOI: 10.1002/mp.70510 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2026. Verfasst von Penghui Luo und 9 weiteren Autor:innen. Beteiligte Einrichtung: Medical Imaging Center, Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, China. Hauptthemen laut MEDLINE: Artifacts, Metals, Magnetic Resonance Imaging, Radio Waves. Die Arbeit nennt 31 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Magnetic resonance imaging (MRI) provides high soft tissue contrast and accurate spatial guidance for interventional procedures. However, metallic needles introduce severe signal voids and phase accumulation that can obscure surrounding anatomy and target lesions, thus compromising procedural accuracy and increasing the risk of injury to adjacent healthy tissue.

Purpose

To reduce metal‐induced artifacts and shorten acquisition time in MRI‐guided interventions while improving imaging precision during needle guidance.

Methods

We propose a simultaneous multi‐band multi‐spectral imaging (SMB‐MSI) sequence that uses multi‐band radiofrequency pulses, designed from off‐resonance field maps estimated using low‐resolution two‐dimensional multi‐spectral imaging (2D MSI) data to acquire multiple spectral bins concurrently. In the current implementation, the proposed SMB‐MSI data were acquired from two simultaneously excited bins and reconstructed using direct complex summation.The performance of SMB‐MSI was evaluated against fast low‐angle shot (FLASH), two‐dimensional fast spin echo (2D FSE), and conventional MSI with different numbers of spectral bins using phantom experiments and ex vivo porcine liver models. Puncture needles were imaged at 0.35 T and 1.5 T. Metal‐induced artifact width was quantified using the full width at half maximum (FWHM), and image signal‐to‐noise ratios (SNRs) were assessed in both phantom and ex vivo porcine liver experiments.

Results

SMB‐MSI markedly reduced artifact width (e.g., 3.8 vs. 5.8 mm and 4.2 vs. 6.6 mm in phantom experiments, and 2.3 vs. 3.7 mm, 2.8 vs. 4.2 mm at 0.35 T and 1.5 T, respectively, relative to five‐bin MSI), while shortening acquisition time by approximately 80% compared with five‐bin MSI. In addition, SMB‐MSI provided higher SNR than conventional MSI in both phantom and ex vivo experiments. Needle tips were clearly visualized with minimal geometric distortion. Consistent improvements were observed in both phantom and ex vivo liver experiments at both field strengths.

Conclusions

SMB‐MSI provides rapid and accurate MRI‐guided needle visualization with substantially reduced metal‐induced artifacts. This approach shows promise for improving the efficiency and precision of MRI‐guided interventional procedures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArtifactsMetalsMagnetic Resonance ImagingRadio WavesAnimalsPhantoms, ImagingSwineImage Processing, Computer-AssistedLiverTime Factors

Stichwörter der Autor:innen

accelerated imagingmetal artifact reductionmulti‐band radiofrequency pulsesmulti‐spectral imaging

Substanzen

Metals

Autor:innen und Institutionen

  • Medical Imaging Center, Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, China.
  • High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China.
  • Anhui Women and Children's Health Center, Hefei, China.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Luo, P., Zhou, J., Chen, L., Wang, C., Yuan, K., Huang, X., Zhou, Y., Jiao, X., Qi, F., & Qiu, B. (2026). Simultaneous multi‐band multi‐spectral imaging using multi‐band RF excitation for accelerated metal artifact reduction in MRI‐guided interventions. Medical Physics. https://doi.org/10.1002/mp.70510

Vancouver

Luo P, Zhou J, Chen L, Wang C, Yuan K, Huang X, et al. Simultaneous multi‐band multi‐spectral imaging using multi‐band RF excitation for accelerated metal artifact reduction in MRI‐guided interventions. Medical Physics. 2026. doi:10.1002/mp.70510

BibTeX
@article{Luo2026,
  author = {Luo, Penghui and Zhou, Jiantai and Chen, Lin and Wang, Changliang and Yuan, Kecheng and Huang, Xiaoyan and Zhou, Yufu and Jiao, Xuechun and Qi, Fulang and Qiu, Bensheng},
  title = {Simultaneous multi‐band multi‐spectral imaging using multi‐band RF excitation for accelerated metal artifact reduction in MRI‐guided interventions},
  journal = {Medical Physics},
  year = {2026},
  doi = {10.1002/mp.70510}
}
Kostenlos starten →