EUVIMEDEUVIMED entdecken
Crossref

256‐channel parallel ultrasound open platform: Enabling high‐resolution imaging and stimulation research

Xuan Fu, Zihan Zhang, Wenfu Lin, Qi Luo, Lvming Zeng, Yunhua Wen, Xuanrong Ji, Zhongwen Cheng

Medical Physics · 2025

DOI: 10.1002/mp.70009 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2025. Verfasst von Xuan Fu und 7 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Precision Electronic Manufacturing Technology and Equipment, Guangdong University of Technology, Guangzhou, China. Hauptthemen laut MEDLINE: Signal-To-Noise Ratio. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key R&D Program of China, China Postdoctoral Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Ultrasound imaging and stimulation are essential tools in various medical applications, enabling non‐invasive diagnostics and targeted therapies. Ultrasound systems that integrate both imaging and stimulation capabilities offer a versatile solution for fundamental research. A high‐performance, programmable platform allows researchers to customize system parameters and explore advanced imaging and stimulation techniques, playing a crucial role in driving innovation in both basic research and clinical applications.

Purpose

This study aims to introduce and validate a novel open ultrasound research platform designed to support both high‐resolution imaging and effective ultrasound stimulation, thereby addressing current research needs in the biomedical field.

Methods

The proposed platform features 256 parallel transmit/receive channels, a 100 MHz sampling rate, 14‐bit analog‐to‐digital converter resolution, and 10 Gb/s optical data transfer. It incorporates plane wave imaging and full matrix capture for high‐resolution, real‐time ultrasound imaging. Additionally, the system is capable of generating customized multi‐cycle waveforms with pulse voltages up to 200 Vpp, enabling neuromodulation and therapeutic applications. It also offers a programmable development environment and compatibility with various phased array probes, providing flexibility for biomedical research. System performance was evaluated using a tissue‐mimicking phantom and a 2 MHz transducer in phased array, plane wave imaging, and full matrix capture modes. Lateral resolution was evaluated using 150 µm tungsten wire imaging, while a 10 MHz transducer validated high‐frequency imaging. A flexible transducer was tested for real‐time imaging on curved surfaces with recalibration for distortion correction. The system's biomedical monitoring capability was demonstrated through carotid artery imaging, while acoustic field measurements, using a hydrophone, showcased its applicability in low‐intensity focused ultrasound therapies.

Results

Imaging experiments using a tissue‐mimicking phantom demonstrate that the platform achieves excellent lateral resolution of 100 µm in ultrasound imaging. Flexible transducer imaging demonstrated a notable improvement in image quality following recalibration, achieving over 100% enhancement. Real‐time monitoring of the human common carotid artery demonstrated accurate dynamic imaging and quantification of heart and respiratory rates. For stimulation applications, hydrophone‐based acoustic field measurements indicate that the system can generate peak positive pressures of up to 1.253 MPa, measured in an open field, reaching the threshold for effective ultrasound stimulation.

Conclusions

This study presents a 256‐channel ultrasound research platform integrating imaging and stimulation functionalities. Through multi‐mode imaging, flexible transducer imaging correction, carotid artery monitoring, and acoustic field measurements, the system's high resolution, real‐time imaging, monitoring capability, and therapeutic potential were validated. These results demonstrate its effectiveness and versatility for advanced biomedical ultrasound applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Signal-To-Noise RatioUltrasonographyPhantoms, ImagingTransducers

Stichwörter der Autor:innen

biomedical researchopen ultrasound platformultrasound imagingultrasound stimulation

Autor:innen und Institutionen

  • State Key Laboratory of Precision Electronic Manufacturing Technology and Equipment, Guangdong University of Technology, Guangzhou, China.
  • Guangzhou Doppler Electronic Technologies Co., Ltd., Guangzhou, China.
  • Ultrasound Department, Sanyuanli Street Community Health Service Center, Guangzhou, China.

Förderung

  • National Natural Science Foundation of China
  • National Key R&D Program of China
  • China Postdoctoral Science Foundation
  • Natural Science Foundation of Guangdong Province
  • National Key Research and Development Program of China

Zitieren

APA

Fu, X., Zhang, Z., Lin, W., Luo, Q., Zeng, L., Wen, Y., Ji, X., & Cheng, Z. (2025). 256‐channel parallel ultrasound open platform: Enabling high‐resolution imaging and stimulation research. Medical Physics. https://doi.org/10.1002/mp.70009

Vancouver

Fu X, Zhang Z, Lin W, Luo Q, Zeng L, Wen Y, et al. 256‐channel parallel ultrasound open platform: Enabling high‐resolution imaging and stimulation research. Medical Physics. 2025. doi:10.1002/mp.70009

BibTeX
@article{Fu2025,
  author = {Fu, Xuan and Zhang, Zihan and Lin, Wenfu and Luo, Qi and Zeng, Lvming and Wen, Yunhua and Ji, Xuanrong and Cheng, Zhongwen},
  title = {256‐channel parallel ultrasound open platform: Enabling high‐resolution imaging and stimulation research},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.70009}
}
Kostenlos starten →