Journal article in Medical Physics, published online on 2025-08-13. Written by Shu Chang and 7 co-authors. Institution: College of Medicine and Biological Information Engineering, Northeastern University, Shenyang, China. Major MEDLINE topics: Magnetic Resonance Imaging, Algorithms, Image Processing, Computer-Assisted, Models, Biological. 28 references. Funded by: National Natural Science Foundation of China, Science and Technology Foundation of Liaoning Provincial, Fundamental Research Funds for the Central Universities.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

The standard Tofts model (STM) is an important pharmacokinetic model for analyzing dynamic contrast enhanced magnetic resonance imaging (DCE‐MRI) data. However, it is very time‐consuming using the STM to perform pixel‐by‐pixel analysis for 3D DCE‐MRI data.

Purpose

We developed a decoupling iterative algorithm, prediction‐correction method (PCM), for rapid calculation of physiological parameters using the STM.

Methods

The idea behind PCM is to eliminate the need to fit the entire contrast agent concentration (C(t)) as function of time (t) curve to calculate the volume transfer constant ( K trans ) and the volume fraction of the extravascular extracellular space ( v e ) using the STM. The early portion of C(t) was used to obtain K trans with prediced v e value, and the late portion of C(t) was used to obtain v e with predicted K trans . This procedure was iteratively performed until the changes of K trans and v e were less than the given tolerance errors. The method was first validated using the quantitative imaging biomarker alliance (QIBA) data. Then the public prostate DCE‐MRI dataset that was scanned twice and the breast DCE‐MRI dataset were used as applications of the PCM and compared with the conventional way of fitting the STM. The repeatability coefficients (RC) of the calculated parameters were also determined.

Results

For QIBA data, there was an excellent agreement for calculating physiological parameters between the PCM and the conventional STM. For clinical data, there was a small percentage error (

Subjects

MeSH terms (MEDLINE)

Magnetic Resonance ImagingAlgorithmsImage Processing, Computer-AssistedModels, BiologicalHumansContrast MediaMaleTime FactorsProstatic NeoplasmsFemale

Author keywords

dynamic contrast enhanced magnetic resonance imaging (DCE‐MRI)pharmacokinetic modelphysiological parametersstandard Tofts model

Substances

Contrast Media

Authors and institutions

  • College of Medicine and Biological Information Engineering, Northeastern University, Shenyang, China.
  • Department of Radiology, University of Chicago, Chicago, Illinois, USA.
  • School of Health Management, China Medical University, Shenyang, China.

Funding

  • National Natural Science Foundation of China
  • Science and Technology Foundation of Liaoning Provincial
  • Fundamental Research Funds for the Central Universities

Cite

APA

Chang, S., Fan, X., Ma, Y., Huang, G., Qi, S., Qian, W., Shi, X., & He, D. (2025). Decoupling iterative algorithm for rapid calculation of physiological parameters from the standard Tofts model. Medical Physics, 52(8). https://doi.org/10.1002/mp.18043

Vancouver

Chang S, Fan X, Ma Y, Huang G, Qi S, Qian W, et al. Decoupling iterative algorithm for rapid calculation of physiological parameters from the standard Tofts model. Medical Physics. 2025;52(8). doi:10.1002/mp.18043

BibTeX
@article{Chang2025,
  author = {Chang, Shu and Fan, Xiaobing and Ma, Ying and Huang, Guantian and Qi, Shouliang and Qian, Wei and Shi, Xin and He, Dianning},
  title = {Decoupling iterative algorithm for rapid calculation of physiological parameters from the standard Tofts model},
  journal = {Medical Physics},
  year = {2025},
  volume = {52},
  number = {8},
  doi = {10.1002/mp.18043}
}
Start for free →