EUVIMEDObjevte EUVIMED
VergleichsstudieOpen access · CC BY 4.0

A comprehensive comparative study of generative adversarial network architectures for synthetic computed tomography generation in the abdomen

Mariia Lapaeva iD, Agustina La Greca Saint-Esteven iD, Philipp Wallimann iD, Nicolaus Andratschke iD, Matthias Guckenberger iD, Manuel Günther iD, Stephanie Tanadini-Lang iD, Riccardo Dal Bello iD

Medical Physics · 2025-08 · 52 (8)

DOI: 10.1002/mp.18038 ↗

At a glance

Vergleichsstudie in Medical Physics, published online on 2025-08-13. Written by Mariia Lapaeva and 7 co-authors. Institution: Department of Radiation Oncology, University Hospital Zurich and University of Zurich, Zurich, Switzerland. Major MEDLINE topics: Abdomen, Generative Adversarial Networks, Image Processing, Computer-Assisted, Tomography, X-Ray Computed. Cited 10 times so far (Crossref); 56 references. The full text is freely available (open access, CC BY 4.0). Funded by: ViewRay Inc. (MASPAC study), SNF R'Equip program, Clinical Research Priority Programme "Artificial intelligence in Oncological Imaging" of the University of Zurich.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

Magnetic Resonance (MR)‐based synthetic Computed Tomography (sCT) generation is an emerging promising technique, required for the transition from conventional planning workflows to MR‐only radiotherapy planning. This shift aims to replace CT acquisition with a sCT improving both cost efficiency and burden to the patient. Generative Adversarial Networks (GANs) have shown some of the best performance in this area.

Purpose

This study aims to identify optimal approaches to improve the quality and clinical applicability of MR‐based sCT generation for treatment planning by performing an extensive comparison of GAN architectures and parameters thereof. It focuses on the abdominal region, which still lacks certified medical products for sCT generation.

Methods

In order to improve the current state of deep learning technologies, we generated sCTs based on abdominal MR images of 154 cancer patients using GANs, varying the following parameters: (1) generator architectures (U‐Net, ResNet); (2) GAN architectures trained in paired (Pix2Pix) and unpaired fashion (CycleGAN and CUT); (3) number of input‐output channels (2D, 2.5D); (4) training set size. The quality of sCT generation was assessed by using both image similarity and dosimetric metrics; correlation between the two was evaluated. The dosimetric accuracy was evaluated through an automated process that compared the dose distributions of photon treatment plans calculated on sCT and CT images, using Dose‐Volume Histogram (DVH) parameters for tumor and organs at risk.

Results

The Pix2Pix model, trained in paired fashion with 2.5D input‐output channels and a ResNet generator emerged as the best‐performing model, achieving a mean absolute error (MAE, mean) of 63.21 HU, a planning target volume Dmean difference of ‐0.09%, and no outliers above 2% for other DVH parameters. This configuration addressed prior challenges of Pix2Pix with bone and rigid organ boundary generation, delivering robust results even for cases with significant air pockets. The 2D input‐output channel configuration showed beneficial for GANs trained in unpaired fashion, achieving a mean MAE of 66.97 HU for CycleGAN and 69.49 HU for CUT. Both delivered clinically applicable results, with mean DVH discrepancies below 0.8%. Expanding the training set size was essential for minimizing outliers in dosimetric parameters. High correlation was observed between the image similarity metrics—MAE, MAE bones, structural similarity index measure—and target DVH parameters, with Pearson coefficients ranging from 0.77 to 0.9. However, within the clinically relevant range of DVH deviations (± 2%), stochastic variations obscured linear trends.

Conclusions

The study provided a new benchmark for the abdominal sCT generation task, showing its clinical applicability for treatment planning and further advancing the state‐of‐the‐art. This study also confirmed that image similarity metrics alone can not reliably predict small dosimetric deviations within a clinical threshold; but contributed by identifying specific metrics that correlate with DVH discrepancies above ± 5%, offering valuable tools for training, evaluation, and standardization of reporting across studies.

Subjects

MeSH terms (MEDLINE)

AbdomenGenerative Adversarial NetworksImage Processing, Computer-AssistedTomography, X-Ray ComputedHumansMagnetic Resonance ImagingRadiotherapy Planning, Computer-Assisted

Author keywords

MR‐only radiotherapydeep learninggenerative adversarial networksmedical image analysissynthetic CT

Authors and institutions

  • Department of Radiation Oncology, University Hospital Zurich and University of Zurich, Zurich, Switzerland.
  • Artificial Intelligence and Machine Learning Group, Department of Informatics, University of Zurich, Zurich, Switzerland.
  • Computer Vision Laboratory, ETH Zurich, Zurich, Switzerland.

ORCID profiles: Mariia Lapaeva, Agustina La Greca Saint-Esteven, Philipp Wallimann, Nicolaus Andratschke, Matthias Guckenberger, Manuel Günther, Stephanie Tanadini-Lang, Riccardo Dal Bello

Funding

  • ViewRay Inc. (MASPAC study)
  • SNF R'Equip program
  • Clinical Research Priority Programme "Artificial intelligence in Oncological Imaging" of the University of Zurich
  • USZ Innovation Pool

Cite

APA

Lapaeva, M., La Greca Saint-Esteven, A., Wallimann, P., Andratschke, N., Guckenberger, M., Günther, M., Tanadini-Lang, S., & Dal Bello, R. (2025). A comprehensive comparative study of generative adversarial network architectures for synthetic computed tomography generation in the abdomen. Medical Physics, 52(8). https://doi.org/10.1002/mp.18038

Vancouver

Lapaeva M, La Greca Saint-Esteven A, Wallimann P, Andratschke N, Guckenberger M, Günther M, et al. A comprehensive comparative study of generative adversarial network architectures for synthetic computed tomography generation in the abdomen. Medical Physics. 2025;52(8). doi:10.1002/mp.18038

BibTeX
@article{Lapaeva2025,
  author = {Lapaeva, Mariia and La Greca Saint-Esteven, Agustina and Wallimann, Philipp and Andratschke, Nicolaus and Guckenberger, Matthias and Günther, Manuel and Tanadini-Lang, Stephanie and Dal Bello, Riccardo},
  title = {A comprehensive comparative study of generative adversarial network architectures for synthetic computed tomography generation in the abdomen},
  journal = {Medical Physics},
  year = {2025},
  volume = {52},
  number = {8},
  doi = {10.1002/mp.18038}
}
Start for free →