Impact of bulk density assignment of bone on MRI‐based abdominal region radiotherapy planning for MR‐linac workflow
Journal of Applied Clinical Medical Physics · 2025
DOI: 10.1002/acm2.70059 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Kota Abe und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, MR Linac ART Division, Graduate School of Medicine, Chiba University, Chiba, Japan. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Magnetic Resonance Imaging, Organs at Risk, Bone and Bones. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: JSPS, Japan Society for the Promotion of Science.
Abstract (Originalsprache)
Purpose
The purpose of the present study was to evaluate the impact of bone relative electron density (rED) assignment on radiotherapy planning for the abdominal region.
Methods
Twenty patients who received abdominal radiotherapy using MR‐Linac and underwent magnetic resonance imaging (MRI) and computed tomography (CT) simulation were analyzed. The reference plan (RP) was established using both CT and MR image sets (RP_CT and RP_MRI). The RP_MRI utilized the bulk density method. The recalculated RPs derived from various rED assignment methods were evaluated for comparison on both datasets. The RPs were recalculated by excluding rED assignment for bones (scenario A). Based on the International Commission on Radiation Units and Measurements report, lung contours were assigned rED of 0.258, and body contours were assigned 1.000 (scenario B) and 1.019 (scenario C). Dose volume histogram (DVH) differences between the three recalculated scenarios and RPs were evaluated. D95, D99, and D1cc were evaluated for target volumes, including gross tumor volume, internal target volume, and planning target volume. DVH parameters, including D1cc for each abdominal organ at risk (OAR) and the mean dose to the liver and kidneys, were evaluated. Three‐dimensional local gamma analysis was conducted to assess dose distribution differences between the three recalculated scenarios and RPs.
Results
In all scenarios of the CT‐ and MRI‐based validation, the average gamma pass rates (2%/2 mm) were higher than 95%. In the CT‐based validation, all target DVHs across the 20 patients showed that none exceeded 2% error in scenario A, whereas 2% and 14% exceeded the threshold in scenarios B and C, respectively. For OARs in CT and MRI‐based validation, absolute maximum dose differences when compared with those of the RP were 0.19 Gy and 0.22 Gy, respectively, in scenario A.
Conclusion
Excluding bone rED considerations in abdominal treatment planning may not yield notable clinical differences.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, MR Linac ART Division, Graduate School of Medicine, Chiba University, Chiba, Japan.
- Department of Radiological Sciences, Komazawa University, Tokyo, Japan.
- Department of Radiology, Chiba University Hospital, Chiba, Japan.
- Diagnostic Radiology and Radiation Oncology, Graduate School of Medicine, Chiba University, Chiba, Japan.
ORCID-Profile: Kota Abe, Masato Tsuneda
Förderung
- JSPS
- Japan Society for the Promotion of Science
Zitieren
APA
Abe, K., Tsuneda, M., Fujita, Y., Abe, Y., & Uno, T. (2025). Impact of bulk density assignment of bone on MRI‐based abdominal region radiotherapy planning for MR‐linac workflow. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70059
Vancouver
Abe K, Tsuneda M, Fujita Y, Abe Y, Uno T. Impact of bulk density assignment of bone on MRI‐based abdominal region radiotherapy planning for MR‐linac workflow. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70059
BibTeX
@article{Abe2025,
author = {Abe, Kota and Tsuneda, Masato and Fujita, Yukio and Abe, Yukinao and Uno, Takashi},
title = {Impact of bulk density assignment of bone on MRI‐based abdominal region radiotherapy planning for MR‐linac workflow},
journal = {Journal of Applied Clinical Medical Physics},
year = {2025},
doi = {10.1002/acm2.70059}
}
EUVIMED