EUVIMEDOpdag EUVIMED
ValidierungsstudieOpen access

Development and experimental validation of an in‐house treatment planning system with greedy energy layer optimization for fast IMPT

Aoxiang Wang, Ya-Nan Zhu, Jufri Setianegara, Yuting Lin, Peng Xiao, Qingguo Xie, Hao Gao

Medical Physics · 2025

DOI: 10.1002/mp.17941 ↗

At a glance

Validierungsstudie in Medical Physics, 2025. Written by Aoxiang Wang and 6 co-authors. Institution: Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, China. Major MEDLINE topics: Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated, Proton Therapy. Cited 2 times so far (Crossref); 42 references. The full text is freely available in PubMed Central. Funded by: NCI NIH HHS, NIH HHS, National Institutes of Health.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Intensity‐modulated proton therapy (IMPT) using pencil beam technique scans tumor in a layer by layer, then spot by spot manner. It can provide highly conformal dose to tumor targets and spare nearby organs‐at‐risk (OAR). Fast delivery of IMPT can improve patient comfort and reduce motion‐induced uncertainties. Since energy layer switching time dominants the plan delivery time, reducing the number of energy layers is important for improving delivery efficiency. Although various energy layer optimization (ELO) methods exist, they are rarely experimentally validated or clinically implemented, since it is technically challenging to integrate these methods into commercially available treatment planning system (TPS) that is not open‐source.

Purpose

This work develops and experimentally validates an in‐house TPS (IH‐TPS) that incorporates a novel ELO method for the purpose of fast IMPT.

Methods

The dose calculation accuracy of IH‐TPS is verified against the measured beam data and the RayStation TPS. For treatment planning, a novel ELO method via greed selection algorithm is proposed to reduce energy layer switching time and total plan delivery time. To validate the planning accuracy of IH‐TPS, the 3D gamma index is calculated between IH‐TPS plans and RayStation plans for various scenarios. Patient‐specific quality‐assurance (QA) verifications are conducted to experimentally verify the delivered dose from the IH‐TPS plans for several clinical cases.

Results

Dose distributions in IH‐TPS matched with those from RayStation TPS, with 3D gamma index results exceeding 95% (2 mm, 2%). The ELO method significantly reduced the delivery time while maintaining plan quality. For instance, in a brain case, the number of energy layers was reduced from 78 to 40 (reduction of 38 layers), leading to a 62% reduction in total delivery time. Patient‐specific QA validation with the IBA ProteusONE proton machine confirmed a > 95% pass rate for all cases.

Conclusions

An IH‐TPS equipped with a novel ELO algorithm is developed and experimentally validated for the purpose of fast IMPT, with enhanced delivery efficiency and preserved plan quality.

Subjects

MeSH terms (MEDLINE)

Radiotherapy Planning, Computer-AssistedRadiotherapy, Intensity-ModulatedProton TherapyHumansRadiotherapy DosageTime FactorsAlgorithms

Author keywords

energy layer optimizationproton therapytreatment planning system

Authors and institutions

  • Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, China.
  • Department of Radiation Oncology, University of Kansas Medical Center, Kansas, USA.

Funding

  • NCI NIH HHS
  • NIH HHS
  • National Institutes of Health

Cite

APA

Wang, A., Zhu, Y. N., Setianegara, J., Lin, Y., Xiao, P., Xie, Q., & Gao, H. (2025). Development and experimental validation of an in‐house treatment planning system with greedy energy layer optimization for fast IMPT. Medical Physics. https://doi.org/10.1002/mp.17941

Vancouver

Wang A, Zhu YN, Setianegara J, Lin Y, Xiao P, Xie Q, et al. Development and experimental validation of an in‐house treatment planning system with greedy energy layer optimization for fast IMPT. Medical Physics. 2025. doi:10.1002/mp.17941

BibTeX
@article{Wang2025,
  author = {Wang, Aoxiang and Zhu, Ya-Nan and Setianegara, Jufri and Lin, Yuting and Xiao, Peng and Xie, Qingguo and Gao, Hao},
  title = {Development and experimental validation of an in‐house treatment planning system with greedy energy layer optimization for fast IMPT},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.17941}
}
Start for free →