Absorbed dose differences between twin fetuses for pregnancy patients in CT examinations

Shuiyin Qu, Haoran Jia, Habib Zaidi, Tianwu Xie

Medical Physics · 2025

DOI: 10.1002/mp.17659 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2025. Verfasst von Shuiyin Qu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Radiation Medicine, Fudan University, Shanghai, China. Hauptthemen laut MEDLINE: Radiation Dosage, Fetus, Tomography, X-Ray Computed, Twins. Die Arbeit nennt 33 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Shanghai Explorer Plan Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Estimation of the radiation dose to the fetus is essential for the assessment of radiation risks and benefits to pregnant patients undergoing radiological examinations. During the past decade, the global twinning rate has soared resulting from embryo assistance and increased delivery age. However, to the best of our knowledge, radiation dosimetry in multiple pregnancies from radiological imaging has never been reported before.

Purpose

The purpose of this study is to develop personalized computational models for twin fetuses based on clinical CT images of real pregnant patients and to estimate personalized radiation doses for twin fetuses from abdominal/pelvic CT examinations.

Methods

Personalized computational phantoms representing pregnant females with twins at the second and third trimesters were constructed based on CT images of two pregnant patients. Monte Carlo calculations were performed using the MCNP transport code and three validated CT scanners to estimate the radiation dose of twin fetuses during abdominal and pelvic CT examinations.

Results

The absorbed fetal organ dose was calculated and compared between twins. For the same patient, the absolute difference in fetal organ dose between twins varies between 0.63% and 39.64% with an average value of 12.85%. The estimated total‐body dose differences for twin fetuses were 11.55% and 7.51%, respectively, for pregnant patients at 22 and 30 weeks gestational age.

Conclusion

The variations of body weight and organ mass affect the absorbed dose of twin fetuses. Personalized computational models provide more accurate fetal radiation dosimetry estimates for pregnant patients with twins. This work also contributes to a better understanding of model‐induced uncertainties in external radiation dosimetry for the developing fetus.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation DosageFetusTomography, X-Ray ComputedTwinsHumansFemalePregnancyMonte Carlo MethodPhantoms, ImagingRadiometry

Stichwörter der Autor:innen

computational phantomradiation dosetwin fetusesx‐ray CT

Autor:innen und Institutionen

  • Institute of Radiation Medicine, Fudan University, Shanghai, China.
  • Department of Engineering Physics, Tsinghua University, Beijing, China.
  • Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, Switzerland.
  • Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands.
  • Department of Nuclear Medicine, University of Southern Denmark, Odense, Denmark.
  • University Research and Innovation Center, Óbuda University, Budapest, Hungary.

Förderung

  • National Natural Science Foundation of China
  • Shanghai Explorer Plan Project

Zitieren

APA

Qu, S., Jia, H., Zaidi, H., & Xie, T. (2025). Absorbed dose differences between twin fetuses for pregnancy patients in CT examinations. Medical Physics. https://doi.org/10.1002/mp.17659

Vancouver

Qu S, Jia H, Zaidi H, Xie T. Absorbed dose differences between twin fetuses for pregnancy patients in CT examinations. Medical Physics. 2025. doi:10.1002/mp.17659

BibTeX
@article{Qu2025,
  author = {Qu, Shuiyin and Jia, Haoran and Zaidi, Habib and Xie, Tianwu},
  title = {Absorbed dose differences between twin fetuses for pregnancy patients in CT examinations},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.17659}
}
Kostenlos starten →