Investigating LETd optimization strategies in carbon ion radiotherapy for pancreatic cancer: a dosimetric study using an anthropomorphic phantom

Filipa Baltazar, Friderike K Longarino, Christina Stengl, Jakob Liermann, Stewart Mein, Jürgen Debus, Thomas Tessonnier, Andrea Mairani

Medical Physics · 2025

DOI: 10.1002/mp.17569 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2025. Verfasst von Filipa Baltazar und 7 weiteren Autor:innen. Beteiligte Einrichtung: Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg, Germany. Hauptthemen laut MEDLINE: Pancreatic Neoplasms, Heavy Ion Radiotherapy, Phantoms, Imaging, Linear Energy Transfer. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Clinical carbon ion beams offer the potential to overcome hypoxia‐induced radioresistance in pancreatic tumors, due to their high dose‐averaged Linear Energy Transfer (LETd), as previous studies have linked a minimum LETd within the tumor to improved local control. Current clinical practices at the Heidelberg Ion‐Beam Therapy Center (HIT), which use two posterior beams, do not fully exploit the LETd advantage of carbon ions, as the high LETd is primarily focused on the beams’ distal edges. Different LETd‐boosting strategies, such as Spot‐scanning Hadron Arc (SHArc), could enhance LETd distribution by concentrating high‐LETd values in potential hypoxic tumor cores while sparing organs at risk.

Purpose

This study aims to investigate and verify different LETd‐boosting strategies using an anthropomorphic pancreas phantom.

Methods

Various LETd‐boosting strategies were investigated for a cylindrical and a pancreas‐shaped target in an anthropomorphic pancreas phantom. Treatment plans were optimized using single field optimization (SFO) or multi field optimization (MFO), with objective functions based on either physical dose (Phys), relative biological effectiveness (RBE)‐weighted dose, or a combination of RBE and LETd‐based objectives (LETopt). The LETd‐boosting planning strategies were optimized with the goal of increasing the minimum LETd in the tumor without compromising its homogeneous dose coverage. Beam configurations investigated included the two‐beam in‐house clinical standard (2‐SFO Phys , 2‐SFO RBE and 2‐MFO RBE‐LETopt ), a three‐beam configuration (3‐MFO RBE and 3‐MFO RBE‐LETopt ) and SHArc (SHArc Phys , SHArc RBE and SHArc RBE‐LETopt ) using step‐and‐shoot delivery. The different plans were verified using an anthropomorphic pancreas phantom at HIT and compared to treatment planning system (TPS) predictions.

Results

All investigated LETd‐boosting strategies altered the LETd distribution while meeting optimization goals and constraints, resulting in varying degrees of LETd enhancement. For the cylindrical volume, the SHArc plan resulted in the highest LETd concentration in the tumor core, with the minimum LETd in the GTV scaling up to 91 keV/µm. For the pancreas‐shaped volume, however, the 3‐MFO RBE‐LETopt achieved a higher minimum LETd in the GTV than SHArc RBE (75.6 and 62.3 keV/µm, respectively). When combining SHArc with LETd optimization, a minimum LETd of 76.3 keV/µm was achieved, suggesting a potential benefit from this combined approach. Most dosimetric verifications showed dose deviations to the TPS within a 5% range, for both beam‐per‐beam and total dose. LETd‐optimized and SHArc plans exhibited slightly higher mean dose deviations (2.0%—4.6%) compared to the standard RBE‐based plans (

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pancreatic NeoplasmsHeavy Ion RadiotherapyPhantoms, ImagingLinear Energy TransferHumansRadiometryRadiotherapy Planning, Computer-AssistedRadiotherapy Dosage

Stichwörter der Autor:innen

LETd‐boostingpancreatic cancerspot‐scanning hadron arc

Autor:innen und Institutionen

  • Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg, Germany.
  • Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
  • Medical Faculty, Heidelberg University, Heidelberg, Germany.
  • Clinical Cooperation Unit Translational Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
  • Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.
  • Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.

Zitieren

APA

Baltazar, F., Longarino, F. K., Stengl, C., Liermann, J., Mein, S., Debus, J., Tessonnier, T., & Mairani, A. (2025). Investigating LETd optimization strategies in carbon ion radiotherapy for pancreatic cancer: a dosimetric study using an anthropomorphic phantom. Medical Physics. https://doi.org/10.1002/mp.17569

Vancouver

Baltazar F, Longarino FK, Stengl C, Liermann J, Mein S, Debus J, et al. Investigating LETd optimization strategies in carbon ion radiotherapy for pancreatic cancer: a dosimetric study using an anthropomorphic phantom. Medical Physics. 2025. doi:10.1002/mp.17569

BibTeX
@article{Baltazar2025,
  author = {Baltazar, Filipa and Longarino, Friderike K and Stengl, Christina and Liermann, Jakob and Mein, Stewart and Debus, Jürgen and Tessonnier, Thomas and Mairani, Andrea},
  title = {Investigating LETd optimization strategies in carbon ion radiotherapy for pancreatic cancer: a dosimetric study using an anthropomorphic phantom},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.17569}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche