Three-dimensional computational evaluation of water-to-air mass stopping power ratio for therapeutic helium-, carbon-, oxygen-, and neon-ion beams and its application to patient-specific quality assurance
Physics in Medicine & Biology · 14.11.2026 · 71 (21) · 215037
DOI: 10.1088/1361-6560/aebc07 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 13.11.2026. Verfasst von Taku Inaniwa und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Accelerator and Medical Physics, Institute for Quantum Medical Science, National Institutes for Quantum Science and Technology (QST), C…. Hauptthemen laut MEDLINE: Helium, Oxygen, Water, Neon. Die Arbeit nennt 64 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science, Exploratory Research for Advanced Technology.
Abstract (Originalsprache)
Objective. Current dosimetry protocols recommend a constant water-to-air mass stopping power ratio, s w,air , of 1.126 with an uncertainty of ±1.5% for light ions, irrespective of ion species and energy. This study aims to develop a computational framework to calculate three-dimensional s w,air distributions of helium-, carbon-, oxygen-, and neon-ion beams for patient specific quality assurance (PSQA), and to systematically investigate spatial variations in s w,air under clinically relevant conditions. Approach. A computational framework was developed to calculate three-dimensional s w,air distributions based on the Bragg-Gray approximation, together with three-dimensional dose distributions for treatment planning. The framework was validated against published datasets for a mono-energetic carbon-ion beam. Treatment plans were generated using helium-, carbon-, oxygen-, and neon-ion beams for rectangular targets with varying spread-out Bragg peak (SOBP) widths and depths, as well as for bone and soft tissue, head and neck, and ocular cases. The corresponding s w,air distributions were calculated in a water phantom and compared with the recommended value of 1.126. Main Results. The mean s w,air within the target increased for shallower targets with narrower SOBP widths. For all ion species, s w,air increased toward the distal end of the SOBP, with larger variations observed for heavier ion species. In neon-ion irradiations for shallow targets, s w,air occasionally exceeded the ±1.5% uncertainty range in a limited region near the distal end of the SOBP. In all other cases, s w,air remained within the uncertainty range. Similar trends were observed in clinical cases. Based on these results, when considering the mean s w,air within the target, the suitable fixed values were 1.128 for carbon and oxygen ions and 1.129 for helium and neon ions. Significance . The proposed computational framework enables three-dimensional, plan-specific evaluation of s w,air and provides a practical approach for improving the dosimetric accuracy in charged-particle therapy with helium, carbon, oxygen, and neon ions, especially for PSQA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Accelerator and Medical Physics, Institute for Quantum Medical Science, National Institutes for Quantum Science and Technology (QST), Chiba, Japan.
- Medical Physics Laboratory, Division of Health Science, Graduate School of Medicine, Osaka University, Osaka, Japan.
- QST Hospital, National Institutes for Quantum Science and Technology (QST), Chiba, Japan.
ORCID-Profile: Taku Inaniwa, Makoto Sakama, Nobuyuki Kanematsu
Förderung
- Japan Society for the Promotion of Science
- Exploratory Research for Advanced Technology
Zitieren
APA
Inaniwa, T., Sakama, M., & Kanematsu, N. (2026). Three-dimensional computational evaluation of water-to-air mass stopping power ratio for therapeutic helium-, carbon-, oxygen-, and neon-ion beams and its application to patient-specific quality assurance. Physics in Medicine & Biology, 71(21), 215037. https://doi.org/10.1088/1361-6560/aebc07
Vancouver
Inaniwa T, Sakama M, Kanematsu N. Three-dimensional computational evaluation of water-to-air mass stopping power ratio for therapeutic helium-, carbon-, oxygen-, and neon-ion beams and its application to patient-specific quality assurance. Physics in Medicine & Biology. 2026;71(21):215037. doi:10.1088/1361-6560/aebc07
BibTeX
@article{Inaniwa2026,
author = {Inaniwa, Taku and Sakama, Makoto and Kanematsu, Nobuyuki},
title = {Three-dimensional computational evaluation of water-to-air mass stopping power ratio for therapeutic helium-, carbon-, oxygen-, and neon-ion beams and its application to patient-specific quality assurance},
journal = {Physics in Medicine & Biology},
year = {2026},
volume = {71},
number = {21},
pages = {215037},
doi = {10.1088/1361-6560/aebc07}
}
EUVIMED