EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

CT‐augmented digital tomosynthesis image reconstruction in image‐guided bronchoscopy interventions

Fatima Saad, Robert Frysch, Sylvia Saalfeld, Stephan Kellnberger, Jessica Schulz, Rebecca Fahrig, Krish Bhadra, Andreas Nürnberger, Georg Rose

Medical Physics · 2025-03 · 52 (3) · 1468-1480

DOI: 10.1002/mp.17551 ↗

At a glance

Journal article in Medical Physics, published online on 2024-12-03. Written by Fatima Saad and 8 co-authors. Institution: Institute for Medical Engineering, Otto-von-Guericke University, Magdeburg, Germany. Major MEDLINE topics: Bronchoscopy, Image Processing, Computer-Assisted, Tomography, X-Ray Computed, Surgery, Computer-Assisted. Cited 1 times so far (Crossref); 25 references. The full text is freely available (open access, CC BY 4.0). Funded by: Europäischer Sozialfonds (ESF), Bundesministerium für Bildung und Forschung (BMBF).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Transbronchial needle biopsy is crucial for diagnosing lung cancer, yet its efficacy depends on accurately localizing the target lesion and biopsy needle. Digital tomosynthesis (DTS) is considered a promising imaging modality for guiding bronchoscopy procedures due to its low radiation dose and small footprint relative to cone‐beam computed tomography (CBCT). However, the image quality of DTS is still not sufficient for an accurate guidance, mainly due to its limited‐angle acquisition.

Purpose

Preoperative computed tomography (CT) scans are often performed prior to bronchoscopy interventions for diagnosis or to plan the procedure. The CT images are of high quality and are characterized by a high spatial resolution compared to intraoperative DTS images. These patient‐specific prior CT images and the intraoperative DTS images share a fair amount of anatomical information. The main differences only stem from patient positioning and respiratory motion. When these differences are addressed properly, prior CT images augment intraoperative DTS image reconstruction with strong prior knowledge and potentially enhance DTS image quality.

Methods

We propose in this work a prior‐aided DTS image reconstruction technique leveraging prior CT images to improve DTS image quality. This technique is based on a recently published deformable CT‐to‐DTS image registration algorithm which is customized for bronchoscopy interventions. The main idea is to register a prior CT image to an intermediate DTS image reconstructed using the standard iterative algebraic reconstruction technique (ART), then to re‐reconstruct the DTS image using ART and the registered prior CT image as a first estimation.

Results

The proposed prior‐aided reconstruction method was tested on a physical phantom and six patient bronchoscopy datasets. Real DTS data acquired with a pseudo‐linear (PL) scan geometry and simulated DTS data generated according to a spherical ellipse (SE) scan geometry were considered. Results evaluated qualitatively by visual inspection and quantitatively by computing Pearson's correlation (PC) with respect to the reference CBCT images suggest significant improvements in image quality using the prior‐aided DTS reconstruction compared to the standard zero‐initialized ART reconstruction. PC coefficients of the six patient datasets were on average and using a zero‐initialized ART reconstruction with SE data and PL data, respectively, and and using the proposed prior‐aided reconstruction with SE data and PL data, respectively.

Conclusions

While the initial estimation in iterative reconstruction algorithms is often overlooked, we proved that initial estimation is of critical importance in DTS image reconstruction and we have demonstrated the profound advantages of integrating prior CT images in intraoperative DTS image reconstruction. CT‐augmented DTS offers a viable alternative to CBCT in guiding bronchoscopy interventions at a fraction of the radiation dose. Further clinical studies are needed to validate improved diagnostic yield.

Subjects

MeSH terms (MEDLINE)

BronchoscopyImage Processing, Computer-AssistedTomography, X-Ray ComputedSurgery, Computer-AssistedHumansPhantoms, Imaging

Author keywords

computed tomographydigital tomosynthesisimage reconstructioninterventional bronchoscopyprior‐aided reconstructiontransbronchial needle biopsy

Authors and institutions

  • Institute for Medical Engineering, Otto-von-Guericke University, Magdeburg, Germany.
  • Research Campus STIMULATE, Otto-von-Guericke University, Magdeburg, Germany.
  • Institute for Medical Informatics and Statistics, University Hospital Schleswig-Holstein, Kiel, Germany.
  • Advanced Therapies, Innovation, Siemens Healthcare AG, Forchheim, Germany.
  • CHI Memorial Rees Skillern Cancer Institute, Chattanooga, Tennessee, USA.
  • Data and Knowledge Engineering Group, Faculty of Computer Science, Otto-von-Guericke University, Magdeburg, Germany.

Funding

  • Europäischer Sozialfonds (ESF)
  • Bundesministerium für Bildung und Forschung (BMBF)

Cite

APA

Saad, F., Frysch, R., Saalfeld, S., Kellnberger, S., Schulz, J., Fahrig, R., Bhadra, K., Nürnberger, A., & Rose, G. (2025). CT‐augmented digital tomosynthesis image reconstruction in image‐guided bronchoscopy interventions. Medical Physics, 52(3), 1468-1480. https://doi.org/10.1002/mp.17551

Vancouver

Saad F, Frysch R, Saalfeld S, Kellnberger S, Schulz J, Fahrig R, et al. CT‐augmented digital tomosynthesis image reconstruction in image‐guided bronchoscopy interventions. Medical Physics. 2025;52(3):1468-1480. doi:10.1002/mp.17551

BibTeX
@article{Saad2025,
  author = {Saad, Fatima and Frysch, Robert and Saalfeld, Sylvia and Kellnberger, Stephan and Schulz, Jessica and Fahrig, Rebecca and Bhadra, Krish and Nürnberger, Andreas and Rose, Georg},
  title = {CT‐augmented digital tomosynthesis image reconstruction in image‐guided bronchoscopy interventions},
  journal = {Medical Physics},
  year = {2025},
  volume = {52},
  number = {3},
  pages = {1468--1480},
  doi = {10.1002/mp.17551}
}
Start for free →