EUVIMEDOpdag EUVIMED
Open access · CC BY-NC 4.0

Fundamental effects of array density and modulation frequency on image quality of diffuse optical tomography

Weihao Fan, Jason W Trobaugh, Chengfeng Zhang, Dalin Yang, Joseph P Culver, Adam T Eggebrecht

Medical Physics · 2025

DOI: 10.1002/mp.17491 ↗

At a glance

Journal article in Medical Physics, 2025. Written by Weihao Fan and 5 co-authors. Institution: Department of Physics, Washington University, St. Louis, Missouri, USA. Major MEDLINE topics: Tomography, Optical. Cited 5 times so far (Crossref); 69 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: NIMH NIH HHS, NINDS NIH HHS, National Institute of Mental Health.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Diffuse optical tomography (DOT) provides three‐dimensional image reconstruction of chromophore perturbations within a turbid volume. Two leading strategies to optimize DOT image quality include, (i) arrays of regular, interlacing, high‐density (HD) grids of sources and detectors with closest spacing less than 15 mm, or (ii) source modulated light of order ∼100 MHz.

Purpose

However, the general principles for how these crucial design parameters of array density and modulation frequency may interact to provide an optimal system design have yet to be elucidated.

Methods

Herein, we systematically evaluated how these design parameters effect image quality via multiple key metrics. Specifically, we simulated 32 system designs with realistic measurement noise and quantified localization error, spatial resolution, signal‐to‐noise, and localization depth of field for each of ∼85 000 point spread functions in each model.

Results

We found that array density had a far stronger effect on image quality metrics than modulation frequency. Additionally, model fits for image quality metrics revealed that potential improvements diminish with regular arrays denser than 9 mm closest spacing. Further, for a given array density, 300 MHz source modulation provided the deepest reliable imaging compared to other frequencies.

Conclusions

Our results indicate that both array density and modulation frequency affect the spatial sampling of tissue, which asymptotically saturates due to photon diffusivity within a turbid volume. In summary, our results provide comprehensive perspectives for optimizing future DOT system designs in applications from wearable functional brain imaging to breast tumor detection.

Subjects

MeSH terms (MEDLINE)

Tomography, OpticalSignal-To-Noise RatioImage Processing, Computer-AssistedHumansImaging, Three-Dimensional

Author keywords

array densitydiffuse optical tomographyfrequency domainfunctional near‐infrared spectroscopyimage qualityinverse problemlocalization depth of fieldmodulation frequencypoint spread functionregularization parametersspatial resolution

Authors and institutions

  • Department of Physics, Washington University, St. Louis, Missouri, USA.
  • Department of Electrical and Systems Engineering, Washington University, St. Louis, Missouri, USA.
  • Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri, USA.
  • Department of Biomedical Engineering, Washington University, St. Louis, Missouri, USA.
  • Department of Neuroscience, Washington University, St. Louis, Missouri, USA.

Funding

  • NIMH NIH HHS
  • NINDS NIH HHS
  • National Institute of Mental Health

Cite

APA

Fan, W., Trobaugh, J. W., Zhang, C., Yang, D., Culver, J. P., & Eggebrecht, A. T. (2025). Fundamental effects of array density and modulation frequency on image quality of diffuse optical tomography. Medical Physics. https://doi.org/10.1002/mp.17491

Vancouver

Fan W, Trobaugh JW, Zhang C, Yang D, Culver JP, Eggebrecht AT. Fundamental effects of array density and modulation frequency on image quality of diffuse optical tomography. Medical Physics. 2025. doi:10.1002/mp.17491

BibTeX
@article{Fan2025,
  author = {Fan, Weihao and Trobaugh, Jason W and Zhang, Chengfeng and Yang, Dalin and Culver, Joseph P and Eggebrecht, Adam T},
  title = {Fundamental effects of array density and modulation frequency on image quality of diffuse optical tomography},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.17491}
}
Start for free →