EUVIMEDEUVIMED entdecken
Open Access

Toward real‐time, volumetric dosimetry for FLASH‐capable clinical synchrocyclotrons using protoacoustic imaging

Siqi Wang, Gilberto Gonzalez, Daniel Rocky Owen, Leshan Sun, Yan Liu, Townsend Zwart, Yong Chen, Liangzhong Xiang

Medical Physics · 2024

DOI: 10.1002/mp.17318 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2024. Verfasst von Siqi Wang und 7 weiteren Autor:innen. Beteiligte Einrichtung: The Department of Biomedical Engineering, University of California, Irvine, California, USA. Hauptthemen laut MEDLINE: Radiometry. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Cancer Institute of the National Institutes of Health under Award Number (U01), National Institutes of Health. Approximately, $500k of federal funds supported the effort (50%) on this project, NCI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Radiation delivery with ultra‐high dose rate (FLASH) radiotherapy (RT) holds promise for improving treatment outcomes and reducing side effects but poses challenges in radiation delivery accuracy due to its ultra‐high dose rates. This necessitates the development of novel imaging and verification technologies tailored to these conditions.

Purpose

Our study explores the effectiveness of proton‐induced acoustic imaging (PAI) in tracking the Bragg peak in three dimensions and in real time during FLASH proton irradiations, offering a method for volumetric beam imaging at both conventional and FLASH dose rates.

Methods

We developed a three‐dimensional (3D) PAI technique using a 256‐element ultrasound detector array for FLASH dose rate proton beams. In the study, we tested protoacoustic signal with a beamline of a FLASH‐capable synchrocyclotron, setting the distal 90% of the Bragg peak around 35 mm away from the ultrasound array. This configuration allowed us to assess various total proton radiation doses, maintaining a consistent beam output of 21 pC/pulse. We also explored a spectrum of dose rates, from 15 Gy/s up to a FLASH rate of 48 Gy/s, by administering a set number of pulses. Furthermore, we implemented a three‐dot scanning beam approach to observe the distinct movements of individual Bragg peaks using PAI. All these procedures utilized a proton beam energy of 180 MeV to achieve the maximum possible dose rate.

Results

Our findings indicate a strong linear relationship between protoacoustic signal amplitudes and delivered doses ( R 2 = 0.9997), with a consistent fit across different dose rates. The technique successfully provided 3D renderings of Bragg peaks at FLASH rates, validated through absolute Gamma index values.

Conclusions

The protoacoustic system demonstrates effectiveness in 3D visualization and tracking of the Bragg peak during FLASH proton therapy, representing a notable advancement in proton therapy quality assurance. This method promises enhancements in protoacoustic image guidance and real‐time dosimetry, paving the way for more accurate and effective treatments in ultra‐high dose rate therapy environments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiometryRadiotherapy DosageTime FactorsProton TherapyAcousticsHumansImaging, Three-Dimensional

Stichwörter der Autor:innen

FLASH protonin vivo dosimetryprotoacoustics

Autor:innen und Institutionen

  • The Department of Biomedical Engineering, University of California, Irvine, California, USA.
  • Department of Radiation Oncology, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA.
  • Mevion Medical Systems, Littleton, Massachusetts, USA.
  • Beckman Laser Institute & Medical Clinic, University of California, Irvine, California, USA.
  • Department of Radiological Sciences, University of California, Irvine, California, USA.

Förderung

  • National Cancer Institute of the National Institutes of Health under Award Number (U01)
  • National Institutes of Health. Approximately, $500k of federal funds supported the effort (50%) on this project
  • NCI NIH HHS
  • UCI Chao Family Comprehensive Cancer Center

Zitieren

APA

Wang, S., Gonzalez, G., Owen, D. R., Sun, L., Liu, Y., Zwart, T., Chen, Y., & Xiang, L. (2024). Toward real‐time, volumetric dosimetry for FLASH‐capable clinical synchrocyclotrons using protoacoustic imaging. Medical Physics. https://doi.org/10.1002/mp.17318

Vancouver

Wang S, Gonzalez G, Owen DR, Sun L, Liu Y, Zwart T, et al. Toward real‐time, volumetric dosimetry for FLASH‐capable clinical synchrocyclotrons using protoacoustic imaging. Medical Physics. 2024. doi:10.1002/mp.17318

BibTeX
@article{Wang2024,
  author = {Wang, Siqi and Gonzalez, Gilberto and Owen, Daniel Rocky and Sun, Leshan and Liu, Yan and Zwart, Townsend and Chen, Yong and Xiang, Liangzhong},
  title = {Toward real‐time, volumetric dosimetry for FLASH‐capable clinical synchrocyclotrons using protoacoustic imaging},
  journal = {Medical Physics},
  year = {2024},
  doi = {10.1002/mp.17318}
}
Kostenlos starten →