Cardio‐respiratory motion compensation for coronary roadmapping in fluoroscopic imaging
Medical Physics · 2024
DOI: 10.1002/mp.17241 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, 2024. Verfasst von Ying Chen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, …. Hauptthemen laut MEDLINE: Movement, Heart. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Beijing AI+ Medicine Program.
Abstract (Originalsprache)
Background
Inferring the shape and position of coronary artery poses challenges when using fluoroscopic image guidance during percutaneous coronary intervention (PCI) procedure. Although angiography enables coronary artery visualization, the use of injected contrast agent raises concerns about radiation exposure and the risk of contrast‐induced nephropathy. To address these issues, dynamic coronary roadmapping overlaid on fluoroscopic images can provide coronary visual feedback without contrast injection.
Purpose
This paper proposes a novel cardio‐respiratory motion compensation method that utilizes cardiac state synchronization and catheter motion estimation to achieve coronary roadmapping in fluoroscopic images.
Methods
For more accurate cardiac state synchronization, video frame interpolation is applied to increase the frame rate of the original limited angiographic images, resulting in higher framerate and more adequate roadmaps. The proposed method also incorporates a multi‐length cross‐correlation based adaptive electrocardiogram (ECG) matching to address irregular cardiac motion situation. Furthermore, a shape‐constrained path searching method is proposed to extract catheter structure from both fluoroscopic and angiographic image. Then catheter motion is estimated using a cascaded matching approach with an outlier removal strategy, leading to a final corrected roadmap.
Results
Evaluation of the proposed method on clinical x‐ray images demonstrates its effectiveness, achieving a 92.8% F1 score for catheter extraction on 589 fluoroscopic and angiographic images. Additionally, the method achieves a 5.6‐pixel distance error of the coronary roadmap on 164 intraoperative fluoroscopic images.
Conclusions
Overall, the proposed method achieves accurate coronary roadmapping in fluoroscopic images and shows potential to overlay accurate coronary roadmap on fluoroscopic image in assisting PCI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, China.
- Department of Cardiac Surgery, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
- Institute of Engineering Medicine, Beijing Institute of Technology, Beijing, China.
Förderung
- National Natural Science Foundation of China
- Beijing AI+ Medicine Program
Zitieren
APA
Chen, Y., Ai, D., Yu, Y., Fan, J., Yu, W., Xiao, D., Lin, Y., & Yang, J. (2024). Cardio‐respiratory motion compensation for coronary roadmapping in fluoroscopic imaging. Medical Physics. https://doi.org/10.1002/mp.17241
Vancouver
Chen Y, Ai D, Yu Y, Fan J, Yu W, Xiao D, et al. Cardio‐respiratory motion compensation for coronary roadmapping in fluoroscopic imaging. Medical Physics. 2024. doi:10.1002/mp.17241