EUVIMEDDescoperă EUVIMED
Open access · CC BY 4.0

A novel method for rapid estimation of active bone marrow dose for radiotherapy patients in epidemiological studies

Yeon Soo Yeom, Lior Braunstein, Lindsay M Morton, Kelly L Bolton, Ji Won Choi, Hyeong Yun Choi, Natasha Greenstein, Choonsik Lee

Medical Physics · 2024

DOI: 10.1002/mp.17118 ↗

At a glance

Journal article in Medical Physics, 2024. Written by Yeon Soo Yeom and 7 co-authors. Institution: Department of Radiation Convergence Engineering, Yonsei University, Wonju, Gangwon, Republic of Korea. Major MEDLINE topics: Bone Marrow, Radiotherapy Dosage. 42 references. The full text is freely available (open access, CC BY 4.0). Funded by: NCI NIH HHS, Ministry of Education, National Research Foundation of Korea.

RezumatSubjectsDate bibliograficeCiteRelated studies

Abstract (original language)

Background

In a dedicated effort to improve the assessment of clonal hematopoiesis (CH) and study leukemia risk following radiotherapy, we are developing a large‐scale cohort study among cancer patients who received radiation. To that end, it will be critical to analyze dosimetric parameters of red bone marrow (ABM) exposure in relation to CH and its progression to myeloid neoplasms, requiring reconstruction method for ABM doses of a large‐scale patients rapidly and accurately.

Purpose

To support a large‐scale cohort study on the assessment of clonal hematopoiesis and leukemia risk following radiotherapy, we present a new method for the rapid reconstruction of ABM doses of radiotherapy among cancer patients.

Methods

The key idea of the presented method is to segment patient bones rapidly and automatically by matching a whole‐body computational human phantom, in which the skeletal system is divided into 34 bone sites, to patient CT images via 3D skeletal registration. The automatic approach was used to segment site‐specific bones for 40 radiotherapy patients. Also, we segmented the bones manually. The bones segmented both manually and automatically were then combined with the patient dose matrix calculated by the treatment planning system (TPS) to derive patient ABM dose. We evaluated the performance of the automatic method in geometric and dosimetric accuracy by comparison with the manual approach.

Results

The pelvis showed the best geometric performance [volume overlap fraction (VOF): 52% (mean) with 23% ( σ ) and average distance (AD): 0.8 cm (mean) with 0.5 cm ( σ )]. The pelvis also showed the best dosimetry performance [absorbed dose difference (ADD): 0.7 Gy (mean) with 1.0 Gy ( σ )]. Some bones showed unsatisfactory performances such as the cervical vertebrae [ADD: 5.2 Gy (mean) with 10.8 Gy ( σ )]. This impact on the total ABM dose, however, was not significant. An excellent agreement for the total ABM dose was indeed observed [ADD: 0.4 Gy (mean) with 0.4 Gy ( σ )]. The computation time required for dose calculation using our method was robust (about one minute per patient).

Conclusions

We confirmed that our method estimates ABM doses across treatment sites accurately, while providing high computational efficiency. The method will be used to reconstruct patient‐specific ABM doses for dose‐response assessment in a large cohort study. The method can also be applied to prospective dose calculation within a clinical TPS to support clinical decision making at the point of care.

Subjects

MeSH terms (MEDLINE)

Bone MarrowRadiotherapy DosageHumansRadiation DosageEpidemiologic StudiesTime FactorsRadiometryRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedPhantoms, Imaging

Author keywords

active bone marrow dosecomputational human phantomradiotherapy

Authors and institutions

  • Department of Radiation Convergence Engineering, Yonsei University, Wonju, Gangwon, Republic of Korea.
  • Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, Maryland, USA.
  • Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
  • Department of Medicine, Washington University School of Medicine, St. Louis, Missouri, USA.
  • Department of Physics, Princeton University, Princeton, New Jersey, USA.

Funding

  • NCI NIH HHS
  • Ministry of Education
  • National Research Foundation of Korea
  • NIH HHS
  • Korea Institute of Energy Technology Evaluation and Planning (KETEP) and the Ministry of Trade, Industry & Energy
  • National Institutes of Health

Cite

APA

Yeom, Y. S., Braunstein, L., Morton, L. M., Bolton, K. L., Choi, J. W., Choi, H. Y., Greenstein, N., & Lee, C. (2024). A novel method for rapid estimation of active bone marrow dose for radiotherapy patients in epidemiological studies. Medical Physics. https://doi.org/10.1002/mp.17118

Vancouver

Yeom YS, Braunstein L, Morton LM, Bolton KL, Choi JW, Choi HY, et al. A novel method for rapid estimation of active bone marrow dose for radiotherapy patients in epidemiological studies. Medical Physics. 2024. doi:10.1002/mp.17118

BibTeX
@article{Yeom2024,
  author = {Yeom, Yeon Soo and Braunstein, Lior and Morton, Lindsay M and Bolton, Kelly L and Choi, Ji Won and Choi, Hyeong Yun and Greenstein, Natasha and Lee, Choonsik},
  title = {A novel method for rapid estimation of active bone marrow dose for radiotherapy patients in epidemiological studies},
  journal = {Medical Physics},
  year = {2024},
  doi = {10.1002/mp.17118}
}
Start for free →